Tretyakov, I., Svyatodukh, S., Chumakova, A., Perepelitsa, A., Kaurova, N., Shurakov, A., et al. (2019). Room temperature silicon detector for IR range coated with Ag2S quantum dots. In IRMMW-THz.
Abstract: A silicon has been the chief technological semiconducting material of modern microelectronics and has had a strong influence on all aspects of society. Applications of Si-based optoelectronic devices are limited to the visible and near infrared ranges. The expansion of the Si absorption to shorter wavelengths of the infrared range is of considerable interest to optoelectronic applications. By creating impurity states in Si it is possible to cause sub-band gap photon absorption. Here, we present an elegant and effective technology of extending the photoresponse of towards the IR range. Our approach is based on the use of Ag 2 S quantum dots (QDs) planted on the surface of Si. The specific sensitivity of the Ag 2 S/Si heterostructure is 10 11 cm√HzW -1 at 1.55μm. Our findings open a path towards the future study and development of Si detectors for technological applications.
|
Goltsman, G. (2019). Quantum-photonic integrated circuits. In Proc. IWQO (pp. 22–23).
Abstract: We show the design, a history of development as well as the most successful and promising approaches for QPICs realization based on hybrid nanophotonic-superconducting devices, where one of the key elements of such a circuit is a waveguide integrated superconducting single-photon detector (WSSPD). The potential of integration with fluorescent molecules is discussed also.
|
Korneeva, Y. P., Vodolazov, D. Y., Semenov, A. V., Florya, I. N., Simonov, N., Baeva, E., et al. (2018). Optical single photon detection in micron-scaled NbN bridges. arXiv:1802.02881v1 [cond-mat.supr-con].
Abstract: We demonstrate experimentally that single photon detection can be achieved in micron-wide NbN bridges, with widths ranging from 0.53 μm to 5.15 μm and for photon-wavelengths from 408 nm to 1550 nm. The microbridges are biased with a dc current close to the experimental critical current, which is estimated to be about 50 % of the theoretically expected depairing current. These results offer an alternative to the standard superconducting single-photon detectors (SSPDs), based on nanometer scale nanowires implemented in a long meandering structure. The results are consistent with improved theoretical modelling based on the theory of non-equilibrium superconductivity including the vortex-assisted mechanism of initial dissipation.
|
Tretyakov, I., Kaurova, N., Voronov, B. M., & Goltsman, G. N. (2018). About effect of the temperature operating conditions on the noise temperature and noise bandwidth of the terahertz range NbN hot-electron bolometers. In Proc. 29th Int. Symp. Space Terahertz Technol. (113).
Abstract: Results of an experimental study of the noise temperature (Tn) and noise bandwidth (NBW) of the superconductor NbN hot-electron bolometer (HEB) mixer as a function of its temperature (Tb) and NbN bridge length are presented. It was determined that the NBW of the mixer is significantly wider at temperatures close to the critical ones (Tc) than are values measured at 4.2 K. The NBW of the mixer measured at the heterodyne frequency of 2.5 THz at temperature Tb close to Tc was ~13 GHz, as compared with 6 GHz at Tb = 4.2 K. This experiment clearly demonstrates the limitation of the thermal flow from the NbN bridge at Tb ≪ Tc for mixers manufactured by the in situ technique. This limitation is close in its nature to the Andreev reflection on the superconductor/metal boundary. In this case, the noise temperature of the studied mixer increased from 1100 to 3800 K.
|
Goltsman, G. (2017). Superconducting thin film as infrared heterodyne and direct detectors. In 16th ISEC (pp. 1–3).
Abstract: We present our recent achievements in the development of superconducting nanowire single-photon detectors (SNSPDs) integrated with optical waveguides on a chip. We demonstrate both single-photon counting with up to 90% on-chip-quantum-efficiency (OCDE), and the heterodyne mixing with a close to the quantum limit sensitivity at the telecommunication wavelength using single device.
|
Kahl, O., Ferrari, S., Kovalyuk, V., Vetter, A., Lewes-Malandrakis, G., Nebel, C., et al. (2016). Spectrally resolved single-photon imaging with hybrid superconducting – nanophotonic circuits. arXiv:1609.07857v1 [physics.ins-det].
Abstract: The detection of individual photons is an inherently binary mechanism, revealing either their absence or presence while concealing their spectral information. For multi-color imaging techniques, such as single photon spectroscopy, fluorescence resonance energy transfer microscopy and fluorescence correlation spectroscopy, wavelength discrimination is essential and mandates spectral separation prior to detection. Here, we adopt an approach borrowed from quantum photonic integration to realize a compact and scalable waveguide-integrated single-photon spectrometer capable of parallel detection on multiple wavelength channels, with temporal resolution below 50 ps and dark count rates below 10 Hz. We demonstrate multi-detector devices for telecommunication and visible wavelengths and showcase their performance by imaging silicon vacancy color centers in diamond nanoclusters. The fully integrated hybrid superconducting-nanophotonic circuits enable simultaneous spectroscopy and lifetime mapping for correlative imaging and provide the ingredients for quantum wavelength division multiplexing on a chip.
|
Sidorova, M., Semenov, A., Korneev, A., Chulkova, G., Korneeva, Y., Mikhailov, M., et al. (2018). Electron-phonon relaxation time in ultrathin tungsten silicon film. arXiv:1607.07321v1 [physics.ins-det].
Abstract: Using amplitude-modulated absorption of sub-THz radiation (AMAR) method, we studied electron-phonon relaxation in thin disordered films of tungsten silicide. We found a response time ~ 800 ps at critical temperature Tc = 3.4 K, which scales as minus 3 in the temperature range from 1.8 to 3.4 K. We discuss mechanisms, which can result in a strong phonon bottle-neck effect in a few nanometers thick film and yield a substantial difference between the measured time, characterizing response at modulation frequency, and the inelastic electron-phonon relaxation time. We estimate the electron-phonon relaxation time to be in the range ~ 100-200 ps at 3.4 K.
|
Sidorova, M. V., Kozorezov, A. G., Semenov, A. V., Korneev, A. A., Chulkova, G. M., Korneeva, Y. P., et al. (2018). Non-bolometric bottleneck in electron-phonon relaxation in ultra-thin WSi film. arXiv:1607.07321v4 [physics.ins-det].
Abstract: We developed the model of the internal phonon bottleneck to describe the energy exchange between the acoustically soft ultrathin metal film and acoustically rigid substrate. Discriminating phonons in the film into two groups, escaping and nonescaping, we show that electrons and nonescaping phonons may form a unified subsystem, which is cooled down only due to interactions with escaping phonons, either due to direct phonon conversion or indirect sequential interaction with an electronic system. Using an amplitude-modulated absorption of the sub-THz radiation technique, we studied electron-phonon relaxation in ultrathin disordered films of tungsten silicide. We found an experimental proof of the internal phonon bottleneck. The experiment and simulation based on the proposed model agree well, resulting in tau{e-ph} = 140-190 ps at TC = 3.4 K, supporting the results of earlier measurements by independent techniques.
|
Fedorov, G., Kardakova, A., Gayduchenko, I., Voronov, B. M., Finkel, M., Klapwijk, T. M., et al. (2014). Photothermoelectric response in asymmetric carbon nanotube devices exposed to sub-THz radiation. In Proc. 25th Int. Symp. Space Terahertz Technol. (71).
Abstract: This work reports on the voltage response of asymmetric carbon nanotube devices to sub-THz radiation at the frequency of 140 GHz. The devices contain CNT’s, which are over their length partially suspended and partially Van der Waals bonded to a SiO 2 substrate, causing a difference in thermal contact. Different heat sinking of CNTs by source and drain gives rise to temperature gradient and consequent thermoelectric power (TEP) as such a device is exposed to the sub-THz radiation. Sign of the DC signal, its power and gate voltage dependence observed at room temperature are consistent with this scenario. At liquid helium temperature the observed response is more complex. DC voltage signal of an opposite sign is observed in a narrow range of gate voltages at low temperatures and under low radiation power. We argue that this may indicate a true photovoltaic response from small gap (less than 10meV) CNT’s, an effect never reported before. While it is not clear if the observed effects can be used to develop efficient THz detectors we note that the responsivity of our devices exceeds that of CNT based devices in microwave or THz range reported before at room temperature. Besides at 4.2 K notable increase of the sample conductance (at least four-fold) is observed. Our recent results with asymmetric carbon nanotube devices response to THz radiation (2.5 THz) will also be presented.
|
Ryabchun, S., Smirnov, A., Pentin, I., Vakhtomin, Y., Smirnov, K., Kaurova, N., et al. (2011). Superconducting single photon detector integrated with optical cavity. In Proc. MLPLIT (pp. 143–145). Modern laser physics and laser-information technologies for science and manufacture.
|
Maslennikova, A., Larionov, P., Ryabchun, S., Smirnov, A., Pentin, I., Vakhtomin, Y., et al. (2011). Noise equivalent power and dynamic range of NBN hot-electron bolometers. In Proc. MLPLIT (pp. 146–148). Modern laser physics and laser-information technologies for science and manufacture.
|
Goltsman, G. (2009). Superconducting NbN hot-electron bolometer mixer, direct detector and single-photon counter: from devices to systems.
|
Minaeva, O., Divochiy, A., Korneev, A., Sergienko, A. V., & Goltsman, G. N. (2009). High speed infrared photon counting with photon number resolving superconducting single-photon detectors (SSPDs). In CLEO/Europe – EQEC.
Abstract: A review of development and characterization of the nanostructures consisting of several meander sections, all connected in parallel was presented. Such geometry leads to a significant decrease of the kinetic inductance, without a decrease of the SSPD active area. A new type of SSPDs possess the QE of large-active- area devices, but, simultaneously, allows achieving short response times and the GHz-counting rate. This new generation of superconducting detectors has another significant advantage for quantum key distribution, they have a photon number resolving capability and can distinguish more photons.
|
Baryshev, A. M., Wild, W., Likhachev, S. F., Vdovin, V. F., Goltsman, G. N., & Kardashev, N. S. (2009). Main parameters and instrumentation of Millimetron space mission. In Proc. 20th Int. Symp. Space Terahertz Technol. (108).
Abstract: Millimetron (official RosKosmos name ”Spectrum-M”) is a part of ambitious program called Spectrum intended to cover the whole electromagnetic spectrum with world class facilities. It is an approved mission included in Russian space program with the launch date in 2017..2019 time frame. The Millimetron satellite has a deployable 12 m diameter antenna with inner solid 4..6 m dish and a rim of petals. The mirror design is largely based on Radioastron mission concept that will be launched in 2009. If the antenna is passively cooled by radiation to open space, it would operate at approx. 50 K surface temperature, due to presence of a deployable three layer radiation screen. As a goal, there is a consideration of active cooling of antenna to 4 K, but this will depend on resources available to the project. Lagrangian libration point L2 considered for Millimetron orbit. There are four groups of scientific instruments envisioned: SVLBI instruments Space-Earth VLBI. It will allow to achieve unprecedented spatial resolution. Millimetron mission will attempt to achieve a mm/submm wave SVLBI. For that purpose, a SVLBI instrument covering selected ALMA bands and a standard VLBI band is envisioned, accompanied by a maser reference oscillator, a data digitizing and memory system, and a high speed data transmission link to ground. The ALMA bands can be extended to cover water lines if detector technology allows. Type of detector – heterodyne. Photometer/polarimeter. Recent progress in direct detector cameras with low spectral resolution, allows to propose a large format (5-10 kPixel) photometer camera on board of Millimetron mission. This camera can cover 0.1 – 2 THz region (with adequate amount of pixels per each subband). Wide band moderate resolution imaging spectrometer. Wide band moderate R = 1000 imaging spectrometer type instrument similar to SPICA SAFARI is planned, taking advantage of large cooled dish. It will cover the adequate spectral range allowable by antenna and will also work below 1 THz, as no ground instrument can have a cold main dish. High resolution spectrometer. For high resolution spectroscopy a heterodyne instrument is proposed, conceptually similar to HIFI on Herschel. This instrument will cover interesting frequency spots in 0.5..4 THz frequency range (using central part of antenna for higher frequency). It is sure that advances in LO and mixer technology will allow this frequency coverage.
|
Tarkhov, M., Morozov, D., Mauskopf, P., Seleznev, V., Korneev, A., Kaurova, N., et al. (2006). Single photon counting detector for THz radioastronomy. In Proc. 17th Int. Symp. Space Terahertz Technol. (pp. 119–122).
Abstract: In this paper we present the results of the research on the superconducting NbN-ultrathin-film single- photon detectors (SSPD) which are capable to detect single quanta in middle IR range. The detection mechanism is based on the hotspot formation in quasi-two-dimensional superconducting structures upon photon absorption. Spectral measurements showed that up to 5.7 gm wavelength (52 THz) the SSPD exhibits single-photon sensitivity. Reduction of operation temperature to 1.6 K allowed us to measure quantum efficiency of -4% at 60 THz. Although further decrease of the operation temperature far below 1 K does not lead to any significant increase of quantum efficiency. We expect that the improvement of the SSPD's performance at reduced operation temperature will make SSPD a practical detector with high characteristics for much lower THz frequencies as well.
|
Goltsman, G. N. (2006). Submillimeter superconducting receivers for astronomy, atmospheric studies and other applications. In 31nd IRMW / 14th ICTE (177).
|
Bryerton, E., Percy, R., Bass, R., Schultz, J., Oluleye, O., Lichtenberger, A., et al. (2005). Receiver measurements of pHEB beam lead mixers on 3-μm silicon. In Proc. 30th IRMMW / 13th THz (pp. 271–272).
Abstract: We report on receiver noise measurement results of phonon-cooled HEB beam lead mixers on 3 μm thick silicon. This type of ultra-thin mixer chip with integrated beam leads allows easy assembly into a block and holds great promise for array integration. Receiver measurements from 600-720 GHz are presented with a minimum noise temperature of 500 K at 666 GHz. These results verify the mixer performance of the SOI processing techniques allowing for further design and integration of SOI pHEB mixers in receivers operating above 1 THz.
|
Rubtsova, I., Korneev, A., Matvienko, V., Chulkova, G., Milostnaya, I., Goltsman, G., et al. (2004). Spectral sensitivity, quantum efficiency, and noise equivalent power of NbN superconducting single-photon detectors in the IR range. In Proc. 29th IRMMW / 12th THz (pp. 461–462).
Abstract: We have developed nanostructured NbN superconducting single-photon detectors capable of GHz-rate photon counting in the 0.4 to 5 /spl mu/m wavelength range. Quantum efficiency of 30%, dark count rate 3/spl times/10/sup -4/ s/sup -1/, and NEP=10/sup -20/ W/Hz/sup -1/2/ have been measured at the 1.3-/spl mu/m wavelength for the device operating at 2.0 K.
|
Verevkin, A. A., Ptitsina, N. G., Smirnov, K. V., Goltsman, G. N., Gershenson, E. M., & Yngvesson, K. S. (1997). Direct measurements of electron energy relaxation times at an AlGaAs/GaAs heterointerface in the optical phonon scattering range. In Proc. 4-th Int. Semicond. Device Research Symp. (pp. 55–58).
|
Ekström, H., Kroug, M., Belitsky, V., Kollberg, E., Olsson, H., Goltsman, G., et al. (1996). Hot electron mixers for THz applications. In E. J. Rolfe, & G. Pilbratt (Eds.), Proc. 30th ESLAB (pp. 207–210).
Abstract: We have measured the noise performance of 35 A thin NbN HEB devices integrated with spiral antennas on antireflection coated silicon substrate lenses at 620 GHz. From the noise measurements we have determined a total conversion gain of the receiver of—16 dB, and an intrinsic conversion of about-10 dB. The IF bandwidth of the 35 A thick NbN devices is at least 3 GHz. The DSB receiver noise temperature is less than 1450 K. Without mismatch losses, which is possible to obtain with a shorter device, and with reduced loss from the beamsplitter, we expect to achieve a DSB receiver noise temperature of less ‘than 700 K.
|
Kollberg, E. L., Gershenzon, E., Goltsman, G., & Yngvesson, K. S. (1992). Hot electron mixers, the potential competition. In Proc. ESA Symp. on Photon Detectors for Space Instrumentation (pp. 201–206).
Abstract: There is an urgent need in radio astronomy for low noise heterodyne receivers for frequencies above about 500 GHz. It is not certain that mixers based on superconducting quasiparticle tunnelling (SIS mixers) may turn out to be the answer to this need. In order to try to find an alternative way for realizing low noise heterodyne receivers for submillimeter waves, so called hot electron bolometric effects for mixing are now being investigated. Two basically different approaches are tried, one based on semiconductors and one on superconductors. Both methods are briefly discussed in this overview paper.
|
Gershenzon, E. M., Goltsman, G. N., & Orlov, L. (1976). Investigation of population and ionization of donor excited states in Ge. In Physics of Semiconductors (pp. 631–634). North-Holland Publishing Co.
|
Goltsman, G. (1972). Simple method for stabilizing power of submillimetric spectrometer. Pribory i Tekhnika Eksperimenta, (1), 136.
|
Averkin, A. S., Shishkin, A. G., Chichkov, V. I., Voronov, B. M., Goltsman, G. N., Karpov, A., et al. (2014). Tunable frequency-selective surface based on superconducting split-ring resonators. In 8th Metamaterials.
Abstract: We study a possibility to use the 2D superconducting metamaterial as a tunable frequency-selective surface (FSS). The proposed FSS is made of sub-wavelength size (l/14) metamaterial unit cells, where a split-ring resonator is embedded in a small iris aperture in a metal plane. The split-ring resonator is made of NbN film, and its resonance frequency is tuned by the temperature of the sample, changing the kinetic inductance of NbN film. The Ansoft HFSS simulation predicts the FSS tuning range of about 10-20 %. The developed superconducting FSS may be used as a tunable band-pass filter or modulator.
|
Smirnov, K., Vachtomin, Y., Divochiy, A., Antipov, A., & Goltsman, G. (2015). The limitation of noise equivalent power by background radiation for infrared superconducting single photon detectors coupled to standard single mode optical fibers. Rus. J. Radio Electron., (5).
Abstract: We investigated the minimum level of the dark count rates and noise equivalent power of superconducting single photon detectors coupled to standard single mode optical fibers. We found that background radiation limits the minimum level of the dark count rates. We also proposed the effective method for reducing background radiation out of the required spectral range of the detector. Measured noise equivalent power of detector reaches 8.9×10-19 W×Hz1/2 at a wavelength of 1.55 μm and quantum efficiency 35%.
|
Semenov, A. V., Devyatov, I. A., Korneev, A. A., Smirnov, K. V., Goltsman, G. N., & Melnikov, A. P. (2012). Derivation of expression for thermodynamic potential of “dirty” superconductor. Rus. J. Radio Electron., (4).
Abstract: We derive a formula for thermodynamic potential of dirty superconductor which express it via isotropic quasiclassical Green functions of Usadel theory. Our result allows unify description of dynamic processes and fluctuations in superconducting nano-electronic devices.
|