Details
   web
Records
Author Yagoubov, P.; Kroug, M.; Merkel, H.; Kollberg, E.; Gol'tsman, G.; Svechnikov, S.; Gershenzon, E.
Title Noise temperature and local oscillator power requirement of NbN phonon-cooled hot electron bolometric mixers at terahertz frequencies Type Journal Article
Year 1998 Publication Appl. Phys. Lett. Abbreviated Journal Appl. Phys. Lett.
Volume (down) 73 Issue 19 Pages 2814-2816
Keywords NbN HEB mixers, noise temperature, local oscillator power
Abstract In this letter, the noise performance of NbN-based phonon-cooled hot electron bolometric quasioptical mixers is investigated in the 0.55–1.1 THz frequency range. The best results of the double-sideband <cd><2018>DSB<cd><2019> noise temperature are: 500 K at 640 GHz, 600 K at 750 GHz, 850 K at 910 GHz, and 1250 K at 1.1 THz. The water vapor in the signal path causes significant contribution to the measured receiver noise temperature around 1.1 THz. The devices are made from 3-nm-thick NbN film on high-resistivity Si and integrated with a planar spiral antenna on the same substrate. The in-plane dimensions of the bolometer strip are typically 0.2Ï«2 um. The amount of local oscillator power absorbed in the bolometer is less than 100 nW.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number Serial 911
Permanent link to this record
 

 
Author Mel’nikov, A. P.; Gurvich, Y. A.; Shestakov, L. N.; Gershenzon, E. M.
Title Magnetic field effects on the nonohmic impurity conduction of uncompensated crystalline silicon Type Journal Article
Year 2001 Publication Jetp Lett. Abbreviated Journal Jetp Lett.
Volume (down) 73 Issue 1 Pages 44-47
Keywords uncompensated crystalline silicon, nonohmic impurity conduction, magnetic field
Abstract The impurity conduction of a series of crystalline silicon samples with the concentration of major impurity N ≈ 3 × 1016 cm−3 and with a varied, but very small, compensation K was measured as a function of the electric field E in various magnetic fields H-σ(H, E). It was found that, at K < 10−3 and in moderate E, where these samples are characterized by a negative nonohmicity (dσ(0, E)/dE < 0), the ratio σ(H, E)/σ(0, E) > 1 (negative magnetoresistance). With increasing E, these inequalities are simultaneously reversed (positive nonohmicity and positive magnetoresistance). It is suggested that both negative and positive nonohmicities are due to electron transitions in electric fields from impurity ground states to states in the Mott-Hubbard gap.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0021-3640 ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number Serial 1752
Permanent link to this record
 

 
Author Siemsen, K. J.; Bernard, J. E.; Madej, A. A.; Marmet, L.
Title Absolute frequency measurement of a CO2/OsO4 stabilized laser at 28.8 THz Type Journal Article
Year 2001 Publication Applied Physics B: Lasers and Optics Abbreviated Journal Appl. Phys. B: Lasers and Optics
Volume (down) 72 Issue Pages 567-573
Keywords HgCdTe detector
Abstract
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number Serial 462
Permanent link to this record
 

 
Author Burke, P. J.; Schoelkopf, R. J.; Prober, D. E.; Skalare, A.; Karasik, B. S.; Gaidis, M. C.; McGrath, W. R.; Bumble, B.; Leduc, H. G.
Title Spectrum of thermal fluctuation noise in diffusion and phonon cooled hot-electron mixers Type Journal Article
Year 1998 Publication Applied Physics Letters Abbreviated Journal Appl. Phys. Lett.
Volume (down) 72 Issue 12 Pages 1516-1518
Keywords HEB mixer; thermal fluctuation noise; TFN
Abstract A systematic study of the intermediate frequency noise bandwidth of Nb thin-film superconducting hot-electron bolometers is presented. We have measured the spectrum of the output noise as well as the conversion efficiency over a very broad intermediate frequency range (from 0.1 to 7.5 GHz) for devices varying in length from 0.08 μm to 3 μm. Local oscillator and rf signals from 8 to 40 GHz were used. For a device of a given length, the spectrum of the output noise and the conversion efficiency behave similarly for intermediate frequencies less than the gain bandwidth, in accordance with a simple thermal model for both the mixing and thermal fluctuation noise. For higher intermediate frequencies the conversion efficiency decreases; in contrast, the noise decreases but has a second contribution which dominates at higher frequency. The noise bandwidth is larger than the gain bandwidth, and the mixer noise is low, between 120 and 530 K (double side band).
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number RPLAB @ gujma @ Serial 760
Permanent link to this record
 

 
Author Nebosis, R. S.; Steinke, R.; Lang, P. T.; Schatz, W.; Heusinger, M. A.; Renk, K. F.; Gol’tsman, G. N.; Karasik, B. S.; Semenov, A. D.; Gershenzon, E. M.
Title Picosecond YBa2Cu3O7−δdetector for far‐infrared radiation Type Journal Article
Year 1992 Publication J. Appl. Phys. Abbreviated Journal J. Appl. Phys.
Volume (down) 72 Issue 11 Pages 5496-5499
Keywords YBCO HTS detectors
Abstract We report on a picosecond YBa2Cu3O7−δ detector for far‐infrared radiation. The detector, consisting of a current carrying structure cooled to liquid‐nitrogen temperature, was studied by use of ultrashort laser pulses from an optically pumped far‐infrared laser in the frequency range from 25 to 215 cm−1. We found that the sensitivity (1 mV/W) was almost constant in this frequency range. We estimated a noise equivalent power of less than 5×10−7 W Hz−1/2. Taking into account the results of a mixing experiment (in the frequency range from 4 to 30 cm−1) we suggest that the response time of the detector was few picoseconds.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0021-8979 ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number Serial 1668
Permanent link to this record