Baselmans, J. J. A.; Hajenius, M.; Gao, J. R.; Klapwijk, T. M.; de Korte, P. A. J.; Voronov, B.; Gol'tsman, G. |
Title |
Noise performance of NbN hot electron bolometer mixers at 2.5 THz and its dependence on the contact resistance |
Type |
Conference Article |
Year |
2003 |
Publication |
Proc. 14th Int. Symp. Space Terahertz Technol. |
Abbreviated Journal |
Proc. 14th Int. Symp. Space Terahertz Technol. |
Volume ![sorted by Volume (numeric) field, ascending order (up)](img/sort_asc.gif) |
|
Issue |
|
Pages |
11-19 |
Keywords |
NbN HEB mixers |
Abstract |
NbN hot electron bolometer mixers (HEBM) are at this moment the best heterodyne receivers for frequencies above 1 Thz. However, the fabrication procedure of these devices is such that the quality of the interface between the NbN superconducting film and the contact structure is not under good control. The result is a low transparency interface between the bolometer itself and the contact/antenna structure. In this paper we report a detailed experimental study on a novel idea to increase the transparency of this interface. This leads to a record sensitivity and more reproducible performance. We compare identical bolometers, coupled with a spiral antenna, with different NbN bolometer-contact pad interfaces. We find that cleaning the NbN interface alone results in an increase in the noise temperature. However, cleaning the NbN interface and adding a thin additional superconductor prior to the gold contact deposition improves the noise temperature of the HEBm with more than a factor of 2. A device with a contact pad on top of an in-situ cleaned NbN film consisting of 10 nm of NbTiN and 40 nm of gold has a DSB noise temperature of 1050 K at 2.5 THz. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1497 |
Permanent link to this record |
|
|
|
Author |
Yagoubov, P. L.; Hoogeveen, R. W. M.; Maurellis, A. M.; Mair, U.; Krocka, M.; Wagner, G.; Birk, M.; Hiibers, H.-W.; Richter, H.; Semenov, A.; Gol'tsman, G.; Voronov, B.; Koshelets, V.; Shitov, S.; Ellison, B.; Kerridge, B.; Matheson, D.; Alderman, B.; Harman, M.; Siddans, R.; Reburn, J. |
Title |
TELIS — development of a new balloon borne THz/submm heterodyne limb sounder |
Type |
Conference Article |
Year |
2003 |
Publication |
Proc. 14th Int. Symp. Space Terahertz Technol. |
Abbreviated Journal |
Proc. 14th Int. Symp. Space Terahertz Technol. |
Volume ![sorted by Volume (numeric) field, ascending order (up)](img/sort_asc.gif) |
|
Issue |
|
Pages |
204-214 |
Keywords |
limb-sounder, TELIS |
Abstract |
We present a design concept for a new state-of-the-art balloon borne atmospheric monitor that will allow enhanced limb sounding of the Earth's atmosphere within the submillimeter and far-infrared wavelength spectral range: TELIS, TErahertz and submm LImb Sounder. The instrument is being developed by a consortium of major European institutes that includes the Space Research Organisation of the Netherlands (SRON), the Rutherford Appleton Laboratory (RAL) in the United Kingdom and the Deutschen Zentrum far Luft- und Raumfahrt (DLR) in Germany (lead institute). TELIS will utilise state-of-the-art superconducting heterodyne technology and is designed to be a compact, lightweight instrument capable of providing broad spectral coverage, high spectral resolution and long flight duration (-24 hours duration during a single flight campaign). The combination of high sensitivity and extensive flight duration will allow evaluation of the diurnal variation of key atmospheric constituents such as OH, HO,, C10, BrO together will longer lived constituents such as 0 3 , HCL and N 2 0. Furthermore, TELIS will share a common balloon platform to that of the MIPAS-B Fourier Transform Spectrometer, developed by the Institute of Meteorology and Climate research of the University of Karlsruhe, Germany. MIPAS-B will provide simultaneous and complementary spectral measurements over an extended spectral range. The combination of the TELIS and MIPAS instruments will provide atmospheric scientists with a very powerful observational tool. TELIS will serve as a testbed for new cryogenic heterodyne detection techniques, and as such it will act as a prelude to future spacebome instruments planned by the European Space Agency (ESA). |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1499 |
Permanent link to this record |
|
|
|
Author |
Smirnov, K. V.; Vachtomin, Yu. B.; Antipov, S. V.; Maslennikov, S. N.; Kaurova, N. S.; Drakinsky, V. N.; Voronov, B. M.; Gol'tsman, G. N.; Semenov, A. D.; Richter, H.; Hubers, H.-W. |
Title |
Noise and gain performance of spiral antenna coupled HEB mixers at 0.7 THz and 2.5 THz |
Type |
Conference Article |
Year |
2003 |
Publication |
Proc. 14th Int. Symp. Space Terahertz Technol. |
Abbreviated Journal |
Proc. 14th Int. Symp. Space Terahertz Technol. |
Volume ![sorted by Volume (numeric) field, ascending order (up)](img/sort_asc.gif) |
|
Issue |
|
Pages |
405-412 |
Keywords |
NbN HEB mixers |
Abstract |
Noise and gain performance of hot electron bolometer (HEB) mixers based on ultrathin superconducting NbN films integrated with a spiral antenna was studied. The noise temperature measurements for two samples with different active area of 3 p.m x 0.24 .tni and 1.3 1..tm x 0.12 1.tm were performed at frequencies 0.7 THz and 2.5 THz. The best receiver noise temperatures 370 K and 1600 K, respectively, have been found at these frequencies. The influence of contact resistance between the superconductor and the antenna terminals on the noise temperature of HEB is discussed. The noise and gain bandwidth of 5GHz and 4.2 GHz, respectively, are demonstrated for similar HEB mixer at 0.75 THz. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1502 |
Permanent link to this record |
|
|
|
Author |
Il'in, K.; Siegel, M.; Semenov, A.; Engel, A.; Hübers, H.-W.; Hollmann, E.; Gol'tsman, G.; Voronov, B. |
Title |
Thickness dependence of superconducting properties of ultrathin Nb and NbN films |
Type |
Conference Article |
Year |
2004 |
Publication |
AKF-Frühjahrstagung |
Abbreviated Journal |
|
Volume ![sorted by Volume (numeric) field, ascending order (up)](img/sort_asc.gif) |
|
Issue |
|
Pages |
|
Keywords |
Nb, NbN films, has potential plagiarism |
Abstract |
|
Address |
Berlin-Adlershof |
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1503 |
Permanent link to this record |
|
|
|
Author |
Richter, H.; Semenov, A.; Hubers, H.-W.; Smirnov, K.; Gol’tsman, G.; Voronov, B. |
Title |
Phonon cooled hot-electron bolometric mixer for 1-5 THz |
Type |
Conference Article |
Year |
2004 |
Publication |
Proc. 29th IRMMW / 12th THz |
Abbreviated Journal |
Proc. 29th IRMMW / 12th THz |
Volume ![sorted by Volume (numeric) field, ascending order (up)](img/sort_asc.gif) |
|
Issue |
|
Pages |
241-242 |
Keywords |
NbN HEB mixers |
Abstract |
Heterodyne receivers for applications in astronomy and planetary research need quantum limited sensitivity. In instruments which are currently built for SOFIA and Herschel, superconducting hot electron bolometers (HEB) are used to achieve this goal at frequencies above 1.4 THz. In order to optimize the performance for this frequency of hot electron bolometer mixers with different in-plane dimensions and logarithmic-spiral feed antennas have been investigated. Their noise temperatures and beam patterns were measured. Above 3 THz the best performance was achieved with a superconducting bridge of 2.0/spl times/0.2 /spl mu/m/sup 2/ incorporated in a logarithmic spiral antenna. The DSB noise temperatures were 2700 K, 4700 and 6400 K at 3.1 THz, 4.3 THz and 5.2 THz, respectively. The results demonstrate that the NbN HEB is very well suited as a mixer for THz heterodyne receivers up to at least 5 THz. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1506 |
Permanent link to this record |
|
|
|
Author |
Hübers, Heinz-Wilhelm; Semenov, A.; Richter, H.; Smirnov, K.; Gol'tsman, G.; Voronov, B. |
Title |
Phonon cooled far-infrared hot electron bolometer mixer |
Type |
Abstract |
Year |
2002 |
Publication |
NASA/ADS |
Abbreviated Journal |
NASA/ADS |
Volume ![sorted by Volume (numeric) field, ascending order (up)](img/sort_asc.gif) |
|
Issue |
|
Pages |
|
Keywords |
NbN HEB mixers |
Abstract |
Heterodyne receivers for applications in astronomy need quantum-limited sensitivity. At frequencies above 1.4 THz superconducting hot electron bolometers (HEB) can be used to achieve this goal. We present results of the development of a quasi-optical phonon-cooled NbN HEB mixer for GREAT, the German heterodyne receiver for SOFIA. Different mixers with logarithmic spiral and double slot feed antennas have been investigated with respect to their noise temperature, conversion loss, linearity and beam pattern at several frequencies between 0.7 THz and 5.2 THz. At 2.5 THz a double sideband noise temperature of 2200 K was achieved. The conversion loss was 16 dB. The response of the mixer was linear up to 400 K load temperature. This performance was verified by measuring an emission line of methanol at 2.5 THz. The results demonstrate that the NbN HEB is very well suited as a mixer for FIR heterodyne receivers. |
Address |
Monterey, CA |
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
Far-IR, Sub-mm & MM Detector Technology Workshop, 1-3 April 2002 |
Notes |
id.37 |
Approved |
no |
Call Number |
|
Serial |
1534 |
Permanent link to this record |
|
|
|
Author |
Hübers, H.-W.; Semenov, A.; Richter, H.; Birk, M.; Krocka, M.; Mair, U.; Smirnov, K.; Gol’tsman, G.; Voronov, B. |
Title |
Terahertz Heterodyn Receiver with a hot-electron bolometer mixer |
Type |
Conference Article |
Year |
2002 |
Publication |
Far-IR, Sub-mm & MM Detector Technology Workshop |
Abbreviated Journal |
Far-IR, Sub-mm & MM Detector Technology Workshop |
Volume ![sorted by Volume (numeric) field, ascending order (up)](img/sort_asc.gif) |
|
Issue |
|
Pages |
3-24 |
Keywords |
NbN HEB mixers |
Abstract |
During the past decade major advances have been made regarding low noise mixers for terahertz (THz) heterodyne receivers. State of the art hot-electron-bolometer (HEB) mixers have noise temperatures close to the quantum limit and require less than a µW power from the local oscillator (LO). The technology is now at a point where the performance of a practical receiver employing such mixer, rather than the figures of merit of the mixer itself, are of major concern. We have incorporated a phonon-cooled NbN HEB mixer in a 2.5 THz heterodyne receiver and investigated the performance of the receiver. This yields important information for the development of heterodyne receivers such as GREAT (German receiver for astronomy at THz frequencies aboard SOFIA) [1] and TELIS (Terahertz limb sounder), a balloon borne heterodyne receiver for atmospheric research [2]. Both are currently under development at DLR. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
NASA |
Place of Publication |
|
Editor |
Wolf, U.; Farhoomand, J.; McCreight, C.R. |
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
NASA CP |
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
Volume: 211408 |
Approved |
no |
Call Number |
|
Serial |
1537 |
Permanent link to this record |
|
|
|
Author |
Cherednichenko, S.; Kroug, M.; Yagoubov, P.; Merkel, H.; Kollberg, E.; Yngvesson, K. S.; Voronov, B.; Gol’tsman, G. |
Title |
IF bandwidth of phonon cooled HEB mixers made from NbN films on MgO substrates |
Type |
Conference Article |
Year |
2000 |
Publication |
Proc. 11th Int. Symp. Space Terahertz Technol. |
Abbreviated Journal |
Proc. 11th Int. Symp. Space Terahertz Technol. |
Volume ![sorted by Volume (numeric) field, ascending order (up)](img/sort_asc.gif) |
|
Issue |
|
Pages |
219-227 |
Keywords |
NbN HEB mixers, cinversion gain bandwidth, IF bandwidth |
Abstract |
An investigation of gain and noise bandwidth of phonon-cooled hot-electron bolometric (HEB) mixers is presented. The radiation coupling to the mixers is quasioptical through either a spiral or twin-slot antenna. A maximum gain bandwidth of 4.8 GHz is obtained for mixers based on a 3.5 nm thin NbN film with Tc= 10 K. The noise bandwidth is 5.6 GHz, at the moment limited by parasitic elements in the, device mount fixture. At 0.65 THz the DSB receiver noise temperature is 700-800 К in the IF band 1-2 GHz, and 1150-2700 К in the band 3.5-7 GHz. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1557 |
Permanent link to this record |
|
|
|
Author |
Schubert, J.; Semenov, A.; Gol'tsman, G.; Hübers, H.-W.; Schwaab, G.; Voronov, B.; Gershenzon, E. |
Title |
Noise temperature and sensitivity of a NbN hot-electron mixer at frequencies from 0.7 THz to 5.2 THz |
Type |
Conference Article |
Year |
1999 |
Publication |
Proc. 10th Int. Symp. Space Terahertz Technol. |
Abbreviated Journal |
Proc. 10th Int. Symp. Space Terahertz Technol. |
Volume ![sorted by Volume (numeric) field, ascending order (up)](img/sort_asc.gif) |
|
Issue |
|
Pages |
190-199 |
Keywords |
NbN HEB mixers |
Abstract |
We report on noise temperature measurements of a NbN phonon-cooled hot-electron bolometric mixer at different bias regimes. The device was a 3 nm thick bridge with in-plane dimensions of 1.7 x 0.2 gm 2 integrated in a complementary logarithmic spiral antenna. Measurements were performed at frequencies ranging from 0.7 THz up to 5.2 THz. The measured DSB noise temperatures are 1500 K (0.7 THz), 2200 K (1.4 THz), 2600 K (1.6 THz), 2900 K (2.5 THz), 4000 K (3.1 THz) 5600 K (4.3 THz) and 8800 K (5.2 THz). Two bias regimes are possible in order to achieve low noise temperatures. But only one of them yields sensitivity fluctuations close to the theoretical limit. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1573 |
Permanent link to this record |
|
|
|
Author |
Gerecht, E.; Musante, C. F.; Jian, H.; Zhuang, Y.; Yngvesson, K. S.; Dickinson, J.; Goyette, T.; Waldman, J.; Yagoubov, P. A.; Gol'tsman, G. N.; Voronov, B. M.; Gershenzon, E. M. |
Title |
Improved characteristics of NbN HEB mixers integrated with log-periodic antennas |
Type |
Conference Article |
Year |
1999 |
Publication |
Proc. 10th Int. Symp. Space Terahertz Technol. |
Abbreviated Journal |
Proc. 10th Int. Symp. Space Terahertz Technol. |
Volume ![sorted by Volume (numeric) field, ascending order (up)](img/sort_asc.gif) |
|
Issue |
|
Pages |
200-207 |
Keywords |
NbN HEB mixers |
Abstract |
|
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1574 |
Permanent link to this record |