toggle visibility Search & Display Options

Select All    Deselect All
 |   | 
Details
   print
  Records Links
Author Gershenzon, E. M.; Gol'tsman, G. N.; Karasik, B. S.; Semenov, A. D. url  openurl
  Title Measurement of the energy gap in the compound YBaCu3O9-δ on the basis of the IR absorption spectrum Type Journal Article
  Year 1987 Publication JETP Lett. Abbreviated Journal JETP Lett.  
  Volume (down) 46 Issue 5 Pages 237-238  
  Keywords YBCO HTS detectors  
  Abstract For the first time the long-wave infrared absorption spectrum has been measured by means of the bolometric effect and energy gap for high-temperature superconducting ceramics YBa/sub 2/Cu/sub 3/O/sub 9-delta/ has been determined from absorption threshold. 2delta/kT/sub c/ value is equal to 0.6.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number Serial 1703  
Permanent link to this record
 

 
Author Zhang, Zijing; Zhang, Jianlong; Wu, Long; Zhang, Yong; Zhao, Yuan; Su, Jianzhong doi  openurl
  Title Photon-counting chirped amplitude modulation lidar using a smart premixing method Type Journal Article
  Year 2013 Publication Opt. Lett. Abbreviated Journal Opt. Lett.  
  Volume (down) 38 Issue 21 Pages 4389-4392  
  Keywords photon-counting detector, lidar, Geiger mode APD, Geiger mode lidar  
  Abstract We proposed a new premixing method for photon-counting chirped amplitude modulation lidar (PCCAML). Earlier studies used the counting results of the returned signal detected by a Geiger mode avalanche photodiode detector (Gm-APD) to mix with the reference signal, called the postmixing method. We use an alternative method known as the premixing method, in which the reference signal is used to directly modulate the sampling gate width of the Gm-APD, and the mixing of the returned signal and the reference signal is completed before the Gm-APD. This premixing method is more flexible and may perform better than the postmixing method in terms of signal-to-noise ratio by cutting down a separated mixer commonly used in the postmixing lidar system. Furthermore, this premixing method lowers the demand for the sampling frequency of the Gm-APD. It allows the use of a much wider modulation bandwidth to improve the range accuracy and resolution. To the best of our knowledge, this is the first report to use the premixing method in the PCCAML system, which will benefit future lidar applications.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number Serial 1006  
Permanent link to this record
 

 
Author Gordon, N. T.; Lees, D. J.; Bowen, G.; Phillips, T. S.; Haigh, M.; Jones, C. L.; Maxey, C. D.; Hipwood, L.; Catchpole, R. A. url  doi
openurl 
  Title HgCdTe detectors operating above 200 K Type Journal Article
  Year 2006 Publication J. Electron. Mater. Abbreviated Journal  
  Volume (down) 35 Issue 6 Pages 1140-1144  
  Keywords HgCdTe detector  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0361-5235 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number Serial 467  
Permanent link to this record
 

 
Author Lubzens, D.; Rosenfeld, D.; Nemirovsky, Y. url  doi
openurl 
  Title The noise equivalent temperature difference performance of HgCdTe photodiode array Type Journal Article
  Year 1988 Publication Infrared Physics Abbreviated Journal Infrared Physics  
  Volume (down) 28 Issue 6 Pages 417-423  
  Keywords HgCdTe detector array  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0020-0891 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number Serial 469  
Permanent link to this record
 

 
Author Gershenzon, E. M.; Gershenzon, M. E.; Goltsman, G. N.; Semenov, A. D.; Sergeev, A. V. url  doi
openurl 
  Title Wide-band highspeed Nb and YBaCuO detectors Type Journal Article
  Year 1991 Publication IEEE Trans. Magn. Abbreviated Journal IEEE Trans. Magn.  
  Volume (down) 27 Issue 2 Pages 2836-2839  
  Keywords YBCO, HTS, Nb detectors  
  Abstract The physical limitations on the response time and the nature of nonequilibrium detection of radiation were investigated for Nb and YBCO film in a wide spectral range from millimeter to near-infrared wavelengths. In the case of ideal heat removal from the film, the detection mechanism is connected with an electron heating effect which is not selective over a wide spectral interval. For Nb, the dependence of the response time on the electron mean free path l and temperature T is tau varies as T/sup -2/l/sup -1/. The values of detectivity D* and tau are 3*10/sup 11/ W/sup -1/ Hz/sup 1/2/ cm and 5*10/sup -9/ s at T=1.6 K, respectively. For YBCO film the tau value of 1-2 ps at T=77 K was obtained; the NEP value of 3*10/sup -11/ W-Hz/sup -1/2/ can be obtained at T=77 K in the case of the optimal film matching to the radiation.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0018-9464 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number Serial 239  
Permanent link to this record
 

 
Author Korneeva, Yuliya; Florya, Irina; Vdovichev, Sergey; Moshkova, Mariya; Simonov, Nikita; Kaurova, Natalia; Korneev, Alexander; Goltsman, Gregory doi  openurl
  Title Comparison of hot-spot formation in NbN and MoN thin superconducting films after photon absorption Type Conference Article
  Year 2017 Publication IEEE Transactions on Applied Superconductivity Abbreviated Journal IEEE Transactions on Applied Superconductiv  
  Volume (down) 27 Issue 4 Pages 5  
  Keywords Thin film devices, Superconducitng photoncounting devices, Nanowire single-photon detectors  
  Abstract In superconducting single-photon detectors SSPD

the efficiency of local suppression of superconductivity and hotspot

formation is controlled by diffusivity and electron-phonon

interaction time. Here we selected a material, 3.6-nm-thick MoNx

film, which features diffusivity close to those of NbN traditionally

used for SSPD fabrication, but with electron-phonon interaction

time an order of magnitude larger. In MoNx detectors we study

the dependence of detection efficiency on bias current, photon

energy, and strip width and compare it with NbN SSPD. We

observe non-linear current-energy dependence in MoNx SSPD

and more pronounced plateaus in dependences of detection

efficiency on bias current which we attribute to longer electronphonon

interaction time.
 
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number RPLAB @ kovalyuk @ Serial 1114  
Permanent link to this record
 

 
Author Gershenzon, E. M.; Gol’tsman, G. N.; Semenov, A. D.; Sergeev, A. V. url  doi
openurl 
  Title Mechanism of picosecond response of granular YBaCuO films to electromagnetic radiation Type Journal Article
  Year 1991 Publication IEEE Trans. Magn. Abbreviated Journal IEEE Trans. Magn.  
  Volume (down) 27 Issue 2 Pages 1321-1324  
  Keywords YBCO HTS detectors  
  Abstract Ultrafast mechanisms of radiation detection in granular YBaCuO films are studied in the wide wavelength range from millimeter waves to near infrared. With an increase in radiation frequency, the Josephson detection at the grain-boundary weak links is replaced by electron heating into the grains. This change occurs in the submillimeter wavelength range. The electron-phonon relaxation time tau /sub eph/ is determined from direct measurements, quasi-stationary electron heating measurements, and the frequency dependence of the current at which maximum voltage shift is observed. The temperature dependence of tau /sub eph/ at T<or=40 K was found to be tau /sub eph/ approximately T/sup -1/. The results show that detectors with a response time of a few picoseconds at nitrogen temperature are attainable.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1941-0069 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number Serial 1679  
Permanent link to this record
 

 
Author Ferrari, S.; Kovalyuk, V.; Hartmann, W.; Vetter, A.; Kahl, O.; Lee, C.; Korneev, A.; Rockstuhl, C.; Gol'tsman, G.; Pernice, W. openurl 
  Title Hot-spot relaxation time current dependence in niobium nitride waveguide-integrated superconducting nanowire single-photon detectors Type Journal Article
  Year 2017 Publication Opt. Express Abbreviated Journal Opt. Express  
  Volume (down) 25 Issue 8 Pages 8739-8750  
  Keywords SSPD, SNSPD, photon counting; Infrared; Quantum detectors; Integrated optics; Multiphoton processes; Photon statistics  
  Abstract We investigate how the bias current affects the hot-spot relaxation dynamics in niobium nitride. We use for this purpose a near-infrared pump-probe technique on a waveguide-integrated superconducting nanowire single-photon detector driven in the two-photon regime. We observe a strong increase in the picosecond relaxation time for higher bias currents. A minimum relaxation time of (22 +/- 1)ps is obtained when applying a bias current of 50% of the switching current at 1.7 K bath temperature. We also propose a practical approach to accurately estimate the photon detection regimes based on the reconstruction of the measured detector tomography at different bias currents and for different illumination conditions.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number RPLAB @ kovalyuk @ Serial 1118  
Permanent link to this record
 

 
Author Seliverstov, S.; Maslennikov, S.; Ryabchun, S.; Finkel, M.; Klapwijk, T. M.; Kaurova, N.; Vachtomin, Yu.; Smirnov, K.; Voronov, B.; Goltsman, G. doi  openurl
  Title Fast and sensitive terahertz direct detector based on superconducting antenna-coupled hot electron bolometer Type Journal Article
  Year 2015 Publication IEEE Trans. Appl. Supercond. Abbreviated Journal IEEE Trans. Appl. Supercond.  
  Volume (down) 25 Issue 3 Pages 2300304  
  Keywords HEB detector responsivity, HEB model, numerical calculations, numerical model  
  Abstract We characterize superconducting antenna-coupled hot-electron bolometers for direct detection of terahertz radiation operating at a temperature of 9.0 K. The estimated value of responsivity obtained from lumped-element theory is strongly different from the measured one. A numerical calculation of the detector responsivity is developed, using the Euler method, applied to the system of heat balance equations written in recurrent form. This distributed element model takes into account the effect of nonuniform heating of the detector along its length and provides results that are in better agreement with the experiment. At a signal frequency of 2.5 THz, the measured value of the optical detector noise equivalent power is 2.0 × 10-13 W · Hz-0.5. The value of the bolometer time constant is 35 ps. The corresponding energy resolution is about 3 aJ. This detector has a sensitivity similar to that of the state-of-the-art sub-millimeter detectors operating at accessible cryogenic temperatures, but with a response time several orders of magnitude shorter.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number Serial 953  
Permanent link to this record
 

 
Author Zhang, W.; Miao, W.; Li, S. L.; Zhou, K. M.; Shi, S. C.; Gao, J. R.; Goltsman, G. N. url  doi
openurl 
  Title Measurement of the spectral response of spiral-antenna coupled superconducting hot electron bolometers Type Journal Article
  Year 2013 Publication IEEE Trans. Appl. Supercond. Abbreviated Journal IEEE Trans. Appl. Supercond.  
  Volume (down) 23 Issue 3 Pages 2300804-2300804  
  Keywords NbN HEB detector  
  Abstract Measured spectral response of spiral-antenna coupled superconducting hot electron bolometers (HEBs) often drops dramatically at frequencies that are still within the frequency range of interest (e.g., ~ 5 THz). This is inconsistent with the implied low receiver noise temperatures from the same measurements. To understand this discrepancy, we exhaustively test and calibrate the thermal sources used in Fourier transform spectrometer measurements. We first investigate the absolute emission spectrum of high-pressure Hg arc lamp, then measure the spectral response of two spiral-antenna coupled NbN HEBs with a Martin-Puplett interferometer as spectrometer and 77 K blackbody as broadband signal source. The measured absolute emission spectrum of Hg arc lamp is proportional to frequency, corresponding to an equivalent blackbody temperature of 4000 K at 1 THz, 1500 K at 3 THz, and 800 K at 5 THz, respectively. Measured spectral response of spiral-antenna coupled NbN HEBs, corrected for air absorption, is nearly flat in the frequency range of 0.5-4 THz, consistent with simulated coupling efficiency between HEB and spiral-antenna. These results explain the discrepancy, and prove that spiral-antenna coupled superconducting NbN HEBs work well in a wide frequency range. In addition, this calibration method and these results are broadly applicable to other quasi-optical THz receivers.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1051-8223 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number Serial 1371  
Permanent link to this record
Select All    Deselect All
 |   | 
Details
   print

Save Citations:
Export Records: