Kampfrath, T., Perfetti, L., von Volkmann, K., Aguirre, C. M., Desjardins, P., Martel, R., et al. (2007). Optical response of single-wall carbon nanotube sheets in the far-infrared spectral range from 1 THz to 40 THz. Phys. Stat. Sol. (B), 244(11), 3950–3954.
Abstract: The optical properties of single-wall carbon nanotube sheets in the far-infrared have been investigated with THz time-domain spectroscopy. Over a wide frequency range from 1 THz to 40 THz, the complex dielectric function of the nanotube sample has been derived. Our data can be excellently reproduced by a Drude-Lorentz model function. The extracted fit parameters such as Lorentz resonance frequency and plasma frequency are consistent with values obtained by scanning tunneling techniques. We discuss the origin of both the Lorentz and Drude contribution in terms of direct and indirect optical transitions.
|
|
|
Fu, K., Zannoni, R., Chan, C., Adams, S. H., Nicholson, J., Polizzi, E., et al. (2008). Terahertz detection in single wall carbon nanotubes. Appl. Phys. Lett., 92(3), 033105.
Abstract: It is reported that terahertz radiation from 0.69 to 2.54 THz has been sensitively detected in a device consisting of bundles of carbon nanotubes containing single wall metallic carbon nanotubes, quasioptically coupled through a lithographically fabricated antenna, and a silicon lens. The measured data are consistent with a bolometric detection process in the metallic tubes and the devices show promise for operation well above 4.2 K.
|
|
|
Fedorov, G., Kardakova, A., Gayduchenko, I., Charayev, I., Voronov, B. M., Finkel, M., et al. (2013). Photothermoelectric response in asymmetric carbon nanotube devices exposed to sub-terahertz radiation. Appl. Phys. Lett., 103(18), 181121 (1 to 5).
Abstract: We report on the voltage response of carbon nanotube devices to sub-terahertz (THz) radiation. The devices contain carbon nanotubes (CNTs), which are over their length partially suspended and partially Van der Waals bonded to a SiO2 substrate, causing a difference in thermal contact. We observe a DC voltage upon exposure to 140 GHz radiation. Based on the observed gate voltage and power dependence, at different temperatures, we argue that the observed signal is both thermal and photovoltaic. The room temperature responsivity in the microwave to THz range exceeds that of CNT based devices reported before. Authors thank Professor P. Barbara for providing the catalyst for CNT growth and Dr. N. Chumakov and V. Rylkov for stimulating discussions. The work was supported by the RFBR (Grant No. 12-02-01291-a) and by the Ministry of Education and Science of the Russian Federation (Contract No. 14.B25.31.0007). G.F. acknowledges support of the RFBR grant 12-02-01005-a.
|
|
|
Fedorov, G., Kardakova, A., Gayduchenko, I., Voronov, B. M., Finkel, M., Klapwijk, T. M., et al. (2014). Photothermoelectric response in asymmetric carbon nanotube devices exposed to sub-THz radiation. In Proc. 25th Int. Symp. Space Terahertz Technol. (71).
Abstract: This work reports on the voltage response of asymmetric carbon nanotube devices to sub-THz radiation at the frequency of 140 GHz. The devices contain CNT’s, which are over their length partially suspended and partially Van der Waals bonded to a SiO 2 substrate, causing a difference in thermal contact. Different heat sinking of CNTs by source and drain gives rise to temperature gradient and consequent thermoelectric power (TEP) as such a device is exposed to the sub-THz radiation. Sign of the DC signal, its power and gate voltage dependence observed at room temperature are consistent with this scenario. At liquid helium temperature the observed response is more complex. DC voltage signal of an opposite sign is observed in a narrow range of gate voltages at low temperatures and under low radiation power. We argue that this may indicate a true photovoltaic response from small gap (less than 10meV) CNT’s, an effect never reported before. While it is not clear if the observed effects can be used to develop efficient THz detectors we note that the responsivity of our devices exceeds that of CNT based devices in microwave or THz range reported before at room temperature. Besides at 4.2 K notable increase of the sample conductance (at least four-fold) is observed. Our recent results with asymmetric carbon nanotube devices response to THz radiation (2.5 THz) will also be presented.
|
|
|
Gayduchenko, I., Kardakova, A., Fedorov, G., Voronov, B., Finkel, M., Jiménez, D., et al. (2015). Response of asymmetric carbon nanotube network devices to sub-terahertz and terahertz radiation. J. Appl. Phys., 118(19), 194303.
Abstract: Demand for efficient terahertz radiation detectors resulted in intensive study of the asymmetric carbon nanostructures as a possible solution for that problem. It was maintained that photothermoelectric effect under certain conditions results in strong response of such devices to terahertz radiation even at room temperature. In this work, we investigate different mechanisms underlying the response of asymmetric carbon nanotube (CNT) based devices to sub-terahertz and terahertz radiation. Our structures are formed with CNT networks instead of individual CNTs so that effects probed are more generic and not caused by peculiarities of an individual nanoscale object. We conclude that the DC voltage response observed in our structures is not only thermal in origin. So called diode-type response caused by asymmetry of the device IV characteristic turns out to be dominant at room temperature. Quantitative analysis provides further routes for the optimization of the device configuration, which may result in appearance of novel terahertz radiation detectors.
|
|