Records |
Author |
Milostnaya, I.; Korneev, A.; Tarkhov, M.; Divochiy, A.; Minaeva, O.; Seleznev, V.; Kaurova, N.; Voronov, B.; Okunev, O.; Chulkova, G.; Smirnov, K.; Gol’tsman, G. |
Title |
Superconducting single photon nanowire detectors development for IR and THz applications |
Type |
Journal Article |
Year |
2008 |
Publication |
J. Low Temp. Phys. |
Abbreviated Journal |
J. Low Temp. Phys. |
Volume |
151 |
Issue |
1-2 |
Pages |
591-596 |
Keywords |
NbN SSPD, SNSPD |
Abstract |
We present our progress in the development of superconducting single-photon detectors (SSPDs) based on meander-shaped nanowires made from few-nm-thick superconducting films. The SSPDs are operated at a temperature of 2–4.2 K (well below T c ) being biased with a current very close to the nanowire critical current at the operation temperature. To date, the material of choice for SSPDs is niobium nitride (NbN). Developed NbN SSPDs are capable of single photon counting in the range from VIS to mid-IR (up to 6 μm) with a record low dark counts rate and record-high counting rate. The use of a material with a low transition temperature should shift the detectors sensitivity towards longer wavelengths. We present state-of-the art NbN SSPDs as well as the results of our recent approach to expand the developed SSPD technology by the use of superconducting materials with lower T c , such as molybdenum rhenium (MoRe). MoRe SSPDs first were made and tested; a single photon response was obtained. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0022-2291 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1244 |
Permanent link to this record |
|
|
|
Author |
Tikhonov, V. V.; Polyakova, O. N.; Gol’tsman, G. N.; Dzardanov, A. L.; Boyarskiy, D. A. |
Title |
Determination of dielectric properties of ore minerals in the microwave band |
Type |
Journal Article |
Year |
2008 |
Publication |
Radiophys. Quant. Electron. |
Abbreviated Journal |
Radiophys. Quant. Electron. |
Volume |
51 |
Issue |
12 |
Pages |
966-974 |
Keywords |
ore complex permittivity, chalcopyrite, magnetite, sphalerite, labradorite |
Abstract |
We consider a method for determining the complex dielectric permittivity of ore and nonmetal minerals in the microwave band of electromagnetic radiation. The results of measuring the reflectivity and transmittivity of chalcopyrite, magnetite, sphalerite, and labradorite samples in the frequency range 77–300 GHz are presented. A method for calculation of the complex dielectric permittivity of minerals on the basis of the obtained experimental data is proposed. The approximation formulas for calculation of the complex dielectric permittivity of the studied minerals are given. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0033-8443 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1404 |
Permanent link to this record |
|
|
|
Author |
Polyakova, O. N.; Tikhonov, V. V.; Dzardanov, A. L.; Boyarskii, D. A.; Gol’tsman, G. N. |
Title |
Dielectric characteristics of ore minerals in a 10–40 GHz frequency range |
Type |
Journal Article |
Year |
2008 |
Publication |
Tech. Phys. Lett. |
Abbreviated Journal |
Tech. Phys. Lett. |
Volume |
34 |
Issue |
11 |
Pages |
967-970 |
Keywords |
ore minerals, complex permittivity, sphalerite, magnetite, labradorite |
Abstract |
A new approach to investigation of the complex dielectric permittivity of both nonmetallic and ore minerals in the microwave frequency range is proposed. Using this approach, data on the complex permittivity of sphalerite, magnetite, and labradorite in a 10–40 GHz frequency range have been obtained for the first time. A method is proposed for calculating the complex permittivity from experimentally measured frequency dependences of the reflection and transmission coefficients of a plane-parallel plate of a given mineral. Approximate expressions that can be used for calculations of the complex refractive index and permittivity of minerals are presented. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1063-7850 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1406 |
Permanent link to this record |
|
|
|
Author |
Mohan, N.; Minaeva, O.; Gol'tsman, G. N.; Nasr, M. B.; Saleh, B. E.; Sergienko, A. V.; Teich, M. C. |
Title |
Photon-counting optical coherence-domain reflectometry using superconducting single-photon detectors |
Type |
Journal Article |
Year |
2008 |
Publication |
Opt. Express |
Abbreviated Journal |
Opt. Express |
Volume |
16 |
Issue |
22 |
Pages |
18118-18130 |
Keywords |
SSPD, SNSPD |
Abstract |
We consider the use of single-photon counting detectors in coherence-domain imaging. Detectors operated in this mode exhibit reduced noise, which leads to increased sensitivity for weak light sources and weakly reflecting samples. In particular, we experimentally demonstrate the possibility of using superconducting single-photon detectors (SSPDs) for optical coherence-domain reflectometry (OCDR). These detectors are sensitive over the full spectral range that is useful for carrying out such imaging in biological samples. With counting rates as high as 100 MHz, SSPDs also offer a high rate of data acquisition if the light flux is sufficient. |
Address |
Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA. nm82@bu.edu |
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1094-4087 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
PMID:18958090 |
Approved |
no |
Call Number |
|
Serial |
1407 |
Permanent link to this record |
|
|
|
Author |
Nasr, M. B.; Minaeva, O.; Goltsman, G. N.; Sergienko, A. V.; Saleh, B. E.; Teich, M. C. |
Title |
Submicron axial resolution in an ultrabroadband two-photon interferometer using superconducting single-photon detectors |
Type |
Journal Article |
Year |
2008 |
Publication |
Opt. Express |
Abbreviated Journal |
Opt. Express |
Volume |
16 |
Issue |
19 |
Pages |
15104-15108 |
Keywords |
SSPD, SNSPD |
Abstract |
We generate ultrabroadband biphotons via the process of spontaneous parametric down-conversion in a quasi-phase-matched nonlinear grating that has a linearly chirped poling period. Using these biphotons in conjunction with superconducting single-photon detectors (SSPDs), we measure the narrowest Hong-Ou-Mandel dip to date in a two-photon interferometer, having a full width at half maximum (FWHM) of approximately 5.7 fsec. This FWHM corresponds to a quantum optical coherence tomography (QOCT) axial resolution of 0.85 µm. Our results indicate that a high flux of nonoverlapping biphotons may be generated, as required in many applications of nonclassical light. |
Address |
Departments of Electrical & Computer Engineering and Physics, Quantum Imaging Laboratory, Boston University, Boston, MA 02215, USA. boshra@bu.edu |
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1094-4087 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
PMID:18795048 |
Approved |
no |
Call Number |
|
Serial |
1408 |
Permanent link to this record |
|
|
|
Author |
de Lara, D. Perez; Ejrnaes, M.; Casaburi, A.; Lisitskiy, M.; Cristiano, R.; Pagano, S.; Gaggero, A.; Leoni, R.; Golt’sman, G.; Voronov, B. |
Title |
Feasibility investigation of NbN nanowires as detector in time-of-flight mass spectrometers for macromolecules of interest in biology (proteins) |
Type |
Journal Article |
Year |
2008 |
Publication |
J. Low Temp. Phys. |
Abbreviated Journal |
J. Low Temp. Phys. |
Volume |
151 |
Issue |
3-4 |
Pages |
771-776 |
Keywords |
NbN SSPD, SNSPD, nanowires |
Abstract |
We are investigating the possibility of using NbN nanowires as detectors in time-of-flight mass spectrometers for investigation of macromolecules of interest in biology (proteins). NbN nanowires could overcome the two major drawbacks encountered so far by cryogenic detectors, namely the low working temperature in the mK region and the slow temporal response. In fact, NbN nanowires can work at 5 K and the response time is at least a factor 10–100 better than that of other cryogenic detectors. We present a feasibility study based on a numerical code to calculate the response of a NbN nanowire. The parameter space is investigated at different energies from IR to macromolecules (i.e. from eV to keV) in order to understand if larger value of film thickness and width can be used for the keV energy region. We also present preliminary experimental results of irradiation with X-ray photons of NbN to simulate the effect of macromolecules of the same energy. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0022-2291 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1410 |
Permanent link to this record |
|
|
|
Author |
Jukna, A.; Kitaygorsky, J.; Pan, D.; Cross, A.; Perlman, A.; Komissarov, I.; Sobolewski, R.; Okunev, O.; Smirnov, K.; Korneev, A.; Chulkova, G.; Milostnaya, I.; Voronov, B.; Gol'tsman, G. |
Title |
Dynamics of hotspot formation in nanostructured superconducting stripes excited with single photons |
Type |
Journal Article |
Year |
2008 |
Publication |
Acta Physica Polonica A |
Abbreviated Journal |
Acta Physica Polonica A |
Volume |
113 |
Issue |
3 |
Pages |
955-958 |
Keywords |
SSPD, SNSPD |
Abstract |
Dynamics of a resistive hotspot formation by near-infrared-wavelength single photons in nanowire-type superconducting NbN stripes was investigated. Numerical simulations of ultrafast thermalization of photon-excited nonequilibrium quasiparticles, their multiplication and out-diffusion from a site of the photon absorption demonstrate that 1.55 μm wavelength photons create in an ultrathin, two-dimensional superconducting film a resistive hotspot with the diameter which depends on the photon energy, and the nanowire temperature and biasing conditions. Our hotspot model indicates that under the subcritical current bias of the 2D stripe, the electric field penetrates the superconductor at the hotspot boundary, leading to suppression of the stripe superconducting properties and accelerated development of a voltage transient across the stripe. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1414 |
Permanent link to this record |
|
|
|
Author |
Chen, J.; Kang, L.; Jin, B. B.; Xu, W. W.; Wu, P. H.; Zhang, W.; Jiang, L.; Li, N.; Shi, S. C.; Gol'tsman, G. N. |
Title |
Properties of terahertz superconducting hot electron bolometer mixers |
Type |
Journal Article |
Year |
2008 |
Publication |
Int. J. Terahertz Sci. Technol. |
Abbreviated Journal |
Int. J. Terahertz Sci. Technol. |
Volume |
1 |
Issue |
1 |
Pages |
37-41 |
Keywords |
NbN HEB mixers, noise temperature |
Abstract |
A quasi-optical superconducting niobium nitride (NbN) hot electron bolometer (HEB) mixer has been fabricated and measured in the terahertz (THz) frequency range of 0.5~2.52 THz. A receiver noise temperature of 2000 K at 2.52 THz has been obtained for the mixer without corrections. Also, the effect of a Parylene C anti-reflection (AR) coating on the silicon (Si) lens has been studied. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1417 |
Permanent link to this record |
|
|
|
Author |
Meledin, Denis; Pavolotsky, Alexey; Desmaris, Vincent.; Lapkin, Igor; Risacher, Christophe; Perez, Victor; Henke, Douglas; Nystrom, Olle; Sundin, Erik; Dochev, Dimitar; Pantaleev, Miroslav; Fredrixon, Mathias; Strandberg, Magnus; Voronov, Boris; Goltsman, Gregory; Belitsky, Victor |
Title |
A 1.3-THz balanced waveguide HEB mixer for the APEX telescope |
Type |
Journal Article |
Year |
2009 |
Publication |
IEEE Trans. Microw. Theory Techn. |
Abbreviated Journal |
|
Volume |
57 |
Issue |
1 |
Pages |
89-98 |
Keywords |
HEB, mixer, waveguide, balanced, NbN |
Abstract |
In this paper, we report about the development, fabrication, and characterization of a balanced waveguide hot electron bolometer (HEB) receiver for the Atacama Pathfinder EXperiment telescope covering the frequency band of 1.25–1.39 THz. The receiver uses a quadrature balanced scheme and two HEB mixers, fabricated from 4- to 5-nm-thick NbN film deposited on crystalline quartz substrate with an MgO buffer layer in between. We employed a novel micromachining method to produce all-metal waveguide parts at submicrometer accuracy (the main-mode waveguide dimensions are 90×180 μm). We present details on the mixer design and measurement results, including receiver noise performance, stability and “first-light†at the telescope site. The receiver yields a double-sideband noise temperature averaged over the RF band below 1200 K, and outstanding stability with a spectroscopic Allan time more than 200 s. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0018-9480 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
RPLAB @ lobanovyury @ |
Serial |
554 |
Permanent link to this record |
|
|
|
Author |
Ryabchun, Sergey; Tong, Cheuk-Yu Edward; Blundell, Raymond; Gol'tsman, Gregory |
Title |
Stabilization scheme for hot-electron bolometer receivers using microwave radiation |
Type |
Journal Article |
Year |
2009 |
Publication |
IEEE Trans. Appl. Supercond. |
Abbreviated Journal |
IEEE Trans. Appl. Supercond. |
Volume |
19 |
Issue |
1 |
Pages |
14-19 |
Keywords |
HEB, mixer, Allan variance, stabilization, radiometer equation |
Abstract |
We present the results of a stabilization scheme for terahertz receivers based on NbN hot-electron bolometer (HEB) mixers that uses microwave radiation with a frequency much lower than the gap frequency of NbN to compensate for mixer current fluctuations. A feedback control loop, which actively controls the power level of the injected microwave radiation, has successfully been implemented to stabilize the operating point of the HEB mixer. This allows us to increase the receiver Allan time to 10 s and also improve the temperature resolution of the receiver by about 30% in the total power mode of operation. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1051-8223 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
RPLAB @ lobanovyury @ |
Serial |
559 |
Permanent link to this record |
|
|
|
Author |
Ryabchun, S. A.; Tretyakov, I. V.; Pentin, I. V.; Kaurova, N. S.; Seleznev, V. A.; Voronov, B. M.; Finkel, M. I.; Maslennikov, S. N.; Gol'tsman, G. N. |
Title |
Low-noise wide-band hot-electron bolometer mixer based on an NbN film |
Type |
Journal Article |
Year |
2009 |
Publication |
Radiophys. Quant. Electron. |
Abbreviated Journal |
|
Volume |
52 |
Issue |
8 |
Pages |
576-582 |
Keywords |
HEB mixer, in-situ contacts, noise temperature, conversion gain bandwidth, diffusion cooling channel |
Abstract |
We develop and study a hot-electron bolometer mixer made of a two-layer NbN–Au film in situ deposited on a silicon substrate. The double-sideband noise temperature of the mixer is 750 K at a frequency of 2.5 THz. The conversion efficiency measurements show that at the superconducting transition temperature, the intermediate-frequency bandwidth amounts to about 6.5 GHz for a mixer 0.112 μm long. These record-breaking characteristics are attributed to the improved contacts between a sensitive element and a helical antenna and are reached due to using the in situ deposition of NbN and Au layers at certain stages of the process. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
599 |
Permanent link to this record |
|
|
|
Author |
Рябчун, С. А.; Третьяков, И. В.; Пентин, И. В; Каурова, Н. С.; Селезнев, В. А; Воронов, Б. М.; Финкель, М. И.; Масленников, С. Н.; Гольцман, Г. Н. |
Title |
Малошумящий широкополосный терагерцовый смеситель на эффекте электронного разогрева в плёнке NbN |
Type |
Journal Article |
Year |
2009 |
Publication |
Известия высших учебных заведений. Радиофизика |
Abbreviated Journal |
|
Volume |
52 |
Issue |
8 |
Pages |
641-648 |
Keywords |
HEB mixer, in-situ contacts, noise temperature, conversion gain bandwidth, diffusion cooling channel |
Abstract |
Разработан и исследован смеситель на горячих электронах, изготовленный из двуслойной плёнки NbN-Au, осаждённой на кремневую подложку in situ. Двухполосная шумовая температура устройства составила 750 К на частоте 2.5 ТГц. Измерения эффективности преобразования для смесителя длиной 0.112 мкм вблизи температуры сверхпроводящего перехода показали полосу промежуточных частот около 6.5 ГГц. Эти результаты являются рекордными и были получены за счёт улучшения контактов между чувствительным элементом и спиральной антенной при замене технологического маршрута с нанесением слоёв NbN и Au в отдельных процессах на технологический процесс, в котором данные слои наносятся in situ без нарушения вакуума. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
600 |
Permanent link to this record |
|
|
|
Author |
Goltsman, G.; Korneev, A.; Divochiy, A.; Minaeva, O.; Tarkhov, M.; Kaurova, N.; Seleznev, V.; Voronov, B.; Okunev, O.; Antipov, A.; Smirnov, K.; Vachtomin, Yu.; Milostnaya, I.; Chulkova, G. |
Title |
Ultrafast superconducting single-photon detector |
Type |
Journal Article |
Year |
2009 |
Publication |
J. Modern Opt. |
Abbreviated Journal |
J. Modern Opt. |
Volume |
56 |
Issue |
15 |
Pages |
1670-1680 |
Keywords |
SSPD, SNSPD |
Abstract |
The state-of-the-art of the NbN nanowire superconducting single-photon detector technology (SSPD) is presented. The SSPDs exhibit excellent performance at 2 K temperature: 30% quantum efficiency from visible to infrared, negligible dark count rate, single-photon sensitivity up to 5.6 µm. The recent achievements in the development of GHz counting rate devices with photon-number resolving capability is presented. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0950-0340 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
RPLAB @ akorneev @ |
Serial |
607 |
Permanent link to this record |
|
|
|
Author |
Ryabchun, Sergey; Tong, Cheuk-Yu Edward; Paine, Scott; Lobanov, Yury; Blundell, Raymond; Goltsman, Gregory |
Title |
Temperature resolution of an HEB receiver at 810 GHz |
Type |
Journal Article |
Year |
2009 |
Publication |
IEEE Trans. Appl. Supercond. |
Abbreviated Journal |
IEEE Trans. Appl. Supercond. |
Volume |
19 |
Issue |
3 |
Pages |
293-296 |
Keywords |
HEB mixer |
Abstract |
We present the results of direct measurements of the temperature resolution of an HEB receiver operating at 810 GHz, in both continuum and spectroscopic modes. In the continuum mode, the input of the receiver was switched between black bodies with different physical temperatures. With a system noise temperature of around 1100 K, the receiver was able to resolve loads which differed in temperature by about 1 K over an integration time of 5 seconds. This resolution is significantly worse than the value of 0.07 K given by the radiometer equation. In the spectroscopic mode, a gas cell filled with carbonyl sulphide (OCS) gas was used and the emission line at 813.3537060 GHz was measured using the receiver in conjunction with a digital spectrometer. From the observed spectra, we determined that the measurement uncertainty of the equivalent emission temperature was 2.8 K for an integration time of 0.25 seconds and a spectral resolution of 12 MHz, compared to a 1.4 K temperature resolution given by the radiometer equation. This relative improvement is due to the fact that at short integration times the contribution from 1/f noise and drift are less dominant. In both modes, the temperature resolution was improved by about 40% with the use of a feedback loop which adjusted the level of an injected microwave radiation to maintain a constant operating current of the HEB mixer. This stabilization scheme has proved to be very effective to keep the temperature resolution of the HEB receiver to close to the theoretical value given by the radiometer equation. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
636 |
Permanent link to this record |
|
|
|
Author |
Ozhegov, R. V.; Okunev, O. V.; Gol’tsman, G. N.; Filippenko, L. V.; Koshelets, V. P. |
Title |
Noise equivalent temperature difference of a superconducting integrated terahertz receiver |
Type |
Journal Article |
Year |
2009 |
Publication |
J. Commun. Technol. Electron. |
Abbreviated Journal |
J. Commun. Technol. Electron. |
Volume |
54 |
Issue |
6 |
Pages |
716-720 |
Keywords |
SIS mixer SIR NETD, FFO, harmonic mixer |
Abstract |
The dependence of the noise equivalent temperature difference (NETD) of a superconducting integrated receiver (SIR) on the receiver noise temperature and the inputsignal level has been investigated. An unprecedented NETD of 13±2 mK has been measured at a SIR noise temperature of 200 K, intermediate-frequency bandwidth of 4 GHz, and time constant of 1 s. With a decrease in the input signal, an improvement in the NETD is observed. This effect is explained by a reduction in the influence of the instabilities of the receiver power supply and the amplification circuit that occur when the input signal is decreased. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1064-2269 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1400 |
Permanent link to this record |