Khosropanah, P., Merkel, H., Yngvesson, S., Adam, A., Cherednichenko, S., & Kollberg, E. (2000). A distributed device model for phonon-cooled HEB mixers predicting IV characteristics, gain, noise and IF bandwidth. In Proc. 11th Int. Symp. Space Terahertz Technol. (pp. 474–488). University of Michigan, Ann Arbor, MI USA.
Abstract: A distributed model for phonon-cooled superconductor hot electron bolometer (HEB) mixers is given, which is based on solving the one-dimensional heat balance equation for the electron temperature profile along the superconductor strip. In this model it is assumed that the LO power is absorbed uniformly along the bridge but the DC power absorption depends on the local resistivity and is thus not uniform. The electron temperature dependence of the resistivity is assumed to be continuous and has a Fermi form. These assumptions are used in setting up the non-linear heat balance equation, which is solved numerically for the electron temperature profile along the bolometer strip. Based on this profile the resistance of the device and the IV curves are calculated. The IV curves are in excellent agreement with measurement results. Using a small signal model the conversion gain of the mixer is obtained. The expressions for Johnson noise and thermal fluctuation noise are derived. The calculated results are in close agreement with measurements, provided that one of the parameters used is adjusted.
|
|
|
Leisawitz, D. T., Danchi, W. C., Dipirro, M. J., Feinberg, L. D., Gezari, D. Y., Hagopian, M., et al. (2000). Scientific motivation and technology requirements for the SPIRIT and SPECS far-infrared/submillimeter space interferometers. In Proc. SPIE (Vol. 4013, pp. 36–46).
Abstract: Far infrared interferometers in space would enable extraordinary measurements of the early universe, the formation of galaxies, stars, and planets, and would have great discovery potential. Since half the luminosity of the universe and 98% of the photons released since the Big Bang are now observable at far IR wavelengths (40 – 500 micrometers ), and the Earth's atmosphere prevents sensitive observations from the ground, this is one of the last unexplored frontiers of space astronomy. We present the engineering and technology requirements that stem from a set of compelling scientific goals and discuss possible configurations for two proposed NASA missions, the Space Infrared Interferometric Telescope and the Submillimeter Probe of the Evolution of Cosmic Structure.
|
|
|
Floet D. W., Gao J. R., Klapwijk T. M., & de Korte P. A. J. (2000). Bias Dependence of the Thermal Time Constant in Nb Superconducting Diffusion-Cooled HEB Mixers. Appl. Phys. Lett., 77, 1719.
Abstract: We present an experimental study of the intermediate frequency bandwidth of a Nb diffusion-cooled hot-electron bolometer mixer for different bias voltages. The measurements show that the bandwidth increases with increasing voltage. Analysis of the data reveals that this effect is mainly caused by a decrease of the intrinsic thermal time of the mixer and that the effect of electrothermal feedback through the intermediate frequency circuit is small. The results are understood using a qualitative model, which takes into account the different effective diffusion constants in the normal and superconducting domains.
|
|
|
Manus, M. K. M., Kash, J. A., Steen, S. E., Polonsky, S., Tsang, J. C., Knebel, D. R., et al. (2000). PICA: Backside failure analysis of CMOS circuits using picosecond imaging circuit analysis. Microelectronics Reliability, 40, 1353–1358.
Abstract: Normal operation of complementary metal-oxide semiconductor (CMOS) devices entails the emission of picosecond pulses of light, which can be used to diagnose circuit problems. The pulses that are observed from submicron sized field effect transistors (FETs) are synchronous with logic state switching. Picosecond Imaging Circuit Analysis (PICA), a new optical imaging technique combining imaging with timing, spatially resolves individual devices at the 0.5 micron level and switching events on a 10 picosecond timescale. PICA is used here for the diagnostics of failures on two VLSI microprocessors.
|
|
|
Cherednichenko, S., Rönnung, F., Gol'tsman, G., Kollberg, E., & Winkler, D. (2000). YBa2Cu3O7−δ hot-electron bolometer mixer. Phys. C: Supercond., 341-348, 2653–2654.
Abstract: We present an investigation of hot-electron bolometric mixer based on YBa2Cu3O7−δ (YBCO) superconducting thin film. Mixer conversion loss, absorbed local oscillator power and intermediate frequency bandwidth was measured at the local oscillator frequency 600 GHz. The fabrication technique for nanoscale YBCO hot-electron bolometer (HEB) mixer integrated into planar antenna structure is described.
|
|