Records |
Author |
Lobanov, Y.V.; Tong, C.-Y.E.; Hedden, A.S.; Blundell, R.; Voronov, B.M.; Gol'tsman, G.N. |
Title |
Direct measurement of the gain and noise bandwidths of HEB mixers |
Type |
Journal Article |
Year |
2011 |
Publication |
IEEE Trans. Appl. Supercond. |
Abbreviated Journal |
IEEE Trans. Appl. Supercond. |
Volume |
21 |
Issue |
3 |
Pages |
645-648 |
Keywords |
waveguide NbN HEB mixers |
Abstract |
The intermediate frequency (IF) bandwidth of a hot electron bolometer (HEB) mixer is an important parameter of the mixer, in that it helps to determine its suitability for a given application. With the availability of wideband low noise amplifiers, it is simple to measure the performance of an HEB mixer over a wide range of IF at a fixed LO frequency using the standard Y-factor method. This in-situ method allows us to measure both the gain and noise bandwidths simultaneously. We have also measured mixer output impedance with a vector network analyser. Intrinsic time constant has been extracted from the impedance data and compared to the mixer's bandwidths determined from receiver Y-factor measurement. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
RPLAB @ gujma @ |
Serial |
720 |
Permanent link to this record |
|
|
|
Author |
Ожегов, Роман Викторович |
Title |
Флуктуационная чувствительность и стабильность приемников с СИС и HEB смесителями для терагерцового тепловидения |
Type |
Journal Article |
Year |
2011 |
Publication |
Радиофизика |
Abbreviated Journal |
|
Volume |
|
Issue |
|
Pages |
135 |
Keywords |
HEB |
Abstract |
|
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
RPLAB @ gujma @ |
Serial |
731 |
Permanent link to this record |
|
|
|
Author |
Kawakami, A; Saito, S.; Hyodo, M. |
Title |
Fabrication of nano-antennas for superconducting Infrared detectors |
Type |
Journal Article |
Year |
2011 |
Publication |
IEEE Trans. Appl. Supercond. |
Abbreviated Journal |
|
Volume |
21 |
Issue |
3 |
Pages |
632-635 |
Keywords |
optical antennas, NbN/MgO/NbN/TiN/Al HEB, dipole antennas, IR, infrared |
Abstract |
To improve the response performance of superconducting infrared detectors, we have developed a fabrication process for nano-antennas. A nano-antenna consists of a dipole antenna, and a superconducting thin film strip placed in the antenna's center. By measuring the transition temperature of the superconducting strips, we confirmed that their superconductivity maintained a good condition after the nano-antenna fabrication process. We also evaluated nano-antenna characteristics using Fourier transform infrared spectroscopy. The evaluated antenna length and width were respectively set at around 2400 nm and 400 nm, and the antennas were placed at intervals of several micrometers around the area of 1 mm2 . In an evaluation of spectral transmission characteristics, clear absorption caused by antenna effects was observed at around 1400 cm-1. High polarization dependencies were also observed. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
761 |
Permanent link to this record |
|
|
|
Author |
Pentin, I. V.; Smirnov, A. V.; Ryabchun, S. A.; Gol’tsman, G. N.; Vaks, V. L.; Pripolzin, S. I.; Paveliev, D. G. |
Title |
Heterodyne source of THz range based on semiconductor superlattice multiplier |
Type |
Conference Article |
Year |
2011 |
Publication |
IRMMW-THz |
Abbreviated Journal |
IRMMW-THz |
Volume |
|
Issue |
|
Pages |
1-2 |
Keywords |
NbN HEB mixer, superlattice |
Abstract |
We present the results of our studies of the possibility of developing a heterodyne receiver incorporating a hot-electron bolometer mixer as the detector and a semiconductor superlattice multiplier driven by a reference synthesizer as the local oscillator. We observe that such a local oscillator offers enough power in the terahertz range to pump the HEB into the operating state. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
6105209 |
Serial |
1384 |
Permanent link to this record |
|
|
|
Author |
Maslennikova, A.; Larionov, P.; Ryabchun, S.; Smirnov, A.; Pentin, I.; Vakhtomin, Yu.; Smirnov, K.; Kaurova, N.; Voronov, B.; Goltsman, G. |
Title |
Noise equivalent power and dynamic range of NBN hot-electron bolometers |
Type |
Conference Article |
Year |
2011 |
Publication |
Proc. MLPLIT |
Abbreviated Journal |
Proc. MLPLIT |
Volume |
|
Issue |
|
Pages |
146-148 |
Keywords |
NbN HEB |
Abstract |
|
Address |
Suzdal / Vladimir (Russia) |
Corporate Author |
|
Thesis |
|
Publisher |
Modern laser physics and laser-information technologies for science and manufacture |
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
1st international russian-chinese conference / youthschool-workshop |
Notes |
September 23-28, 2011 |
Approved |
no |
Call Number |
|
Serial |
1386 |
Permanent link to this record |
|
|
|
Author |
Bruderer, S.; Benz, A. O.; van Dishoeck, E. F.; Melchior, M.; Doty, S. D.; van der Tak, F.; Stäuber, P.; Wampfler, S. F.; Dedes, C.; Yıldız, U. A.; Pagani, L.; Giannini, T.; de Graauw, Th.; Whyborn, N.; Teyssier, D.; Jellema, W.; Shipman, R.; Schieder, R.; Honingh, N.; Caux, E.; Bächtold, W.; Csillaghy, A.; Monstein, C.; Bachiller, R.; Baudry, A.; Benedettini, M.; Bergin, E.; Bjerkeli, P.; Blake, G. A.; Bontemps, S.; Braine, J.; Caselli, P.; Cernicharo, J.; Codella, C.; Daniel, F.; di Giorgio, A. M.; Dominik, C.; Encrenaz, P.; Fich, M.; Fuente, A.; Goicoechea, J. R.; Helmich, F.; Herczeg, G. J.; Herpin, F.; Hogerheijde, M. R.; Jacq, T.; Johnstone, D.; Jørgensen, J. K.; Kristensen, L. E.; Larsson, B.; Lis, D.; Liseau, R.; Marseille, M.; McCoey, C.; Melnick, G.; Neufeld, D.; Nisini, B.; Olberg, M.; Parise, B.; Pearson, J. C.; Plume, R.; Risacher, C.; Santiago-García, J.; Saraceno, P.; Shipman, R.; Tafalla, M.; van Kempen, T. A.; Visser, R.; Wyrowski, F. |
Title |
Herschel/HIFI detections of hydrides towards AFGL 2591. Envelope emission versus tenuous cloud absorption |
Type |
Journal Article |
Year |
2010 |
Publication |
Astron. Astrophys. |
Abbreviated Journal |
|
Volume |
521 |
Issue |
|
Pages |
L44 (1 to 7) |
Keywords |
HEB mixer applications, HIFI, Herschel |
Abstract |
The Heterodyne Instrument for the Far Infrared (HIFI) onboard the Herschel Space Observatory allows the first observations of light diatomic molecules at high spectral resolution and in multiple transitions. Here, we report deep integrations using HIFI in different lines of hydrides towards the high-mass star forming region AFGL 2591. Detected are CH, CH+, NH, OH+, H2O+, while NH+ and SH+ have not been detected. All molecules except for CH and CH+ are seen in absorption with low excitation temperatures and at velocities different from the systemic velocity of the protostellar envelope. Surprisingly, the CH(JF,P = 3/22,- – 1/21,+ ) and CH+(J = 1–0, J = 2–1) lines are detected in emission at the systemic velocity. We can assign the absorption features to a foreground cloud and an outflow lobe, while the CH and CH+ emission stems from the envelope. The observed abundance and excitation of CH and CH+ can be explained in the scenario of FUV irradiated outflow walls, where a cavity etched out by the outflow allows protostellar FUV photons to irradiate and heat the envelope at larger distances driving the chemical reactions that produce these molecules. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1083 |
Permanent link to this record |
|
|
|
Author |
Karasik, Boris S.; Cantor, Robin |
Title |
Optical NEP in hot-electron nanobolometers |
Type |
Journal Article |
Year |
2010 |
Publication |
|
Abbreviated Journal |
|
Volume |
|
Issue |
|
Pages |
1-7 |
Keywords |
HEB, Ti, NEP, femtowatt, SAFARI, SPICA, 650 GHz, 0.65 THz, 460 um, twin slot antenna, SQUID readout |
Abstract |
For the first time, we have measured the optical noise equivalent power (NEP) in titanium (Ti) superconducting hot-electron nanobolometers (nano-HEBs). The bolometers were 2{\mu}mx1{\mu}mx20nm and 1{\mu}mx1{\mu}mx20nm planar antenna-coupled devices. The measurements were done at {\lambda} = 460 {\mu}m using a cryogenic black body radiation source delivering optical power from a fraction of a femtowatt to a few 100s of femtowatts. A record low NEP = 3x10^{-19} W/Hz^{1/2} at 50 mK has been achieved. This sensitivity meets the requirements for SAFARI instrument on the SPICA telescope. The ways for further improvement of the nano-HEB detector sensitivity are discussed. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
To appear in Proc. 21st Int. Symp. on Spc. THz Technol., Oxford, UK, 23-25 March, 2010 |
Approved |
no |
Call Number |
|
Serial |
623 |
Permanent link to this record |
|
|
|
Author |
Zhang, W.; Khosropanah, P.; Gao, J. R.; Kollberg, E. L.; Yngvesson, K. S.; Bansal, T.; Barends, R.; Klapwijk, T. M. |
Title |
Quantum noise in a terahertz hot electron bolometer mixer |
Type |
Journal Article |
Year |
2010 |
Publication |
Applied Physics Letters |
Abbreviated Journal |
Appl. Phys. Lett. |
Volume |
96 |
Issue |
11 |
Pages |
111113-(1-3) |
Keywords |
HEB mixer, quantum limit, quantum noise, vacuum box, THz, Terahertz |
Abstract |
We have measured the noise temperature of a single, sensitive superconducting NbN hot electron bolometer (HEB) mixer in a frequency range from 1.6 to 5.3 THz, using a setup with all the key components in vacuum. By analyzing the measured receiver noise temperature using a quantum noise (QN) model for HEB mixers, we confirm the effect of QN. The QN is found to be responsible for about half of the receiver noise at the highest frequency in our measurements. The beta-factor (the quantum efficiency of the HEB) obtained experimentally agrees reasonably well with the calculated value. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
624 |
Permanent link to this record |
|
|
|
Author |
Tret’yakov, I. V.; Ryabchun, S. A.; Kaurova, N. S.; Larionov, P. A.; Lobastova, A. A.; Voronov, B. M.; Finkel, M. I.; Gol’tsman, G. N. |
Title |
Optimum absorbed heterodyne power for superconducting NbN hot-electron bolometer mixer |
Type |
Journal Article |
Year |
2010 |
Publication |
Tech. Phys. Lett. |
Abbreviated Journal |
Tech. Phys. Lett. |
Volume |
36 |
Issue |
12 |
Pages |
1103-1105 |
Keywords |
NbN HEB mixer |
Abstract |
Absorbed heterodyne power has been measured in a low-noise broadband hot-electron bolometer (HEB) mixer for the terahertz range, operating on the effect of electron heating in the resistive state of an ultrathin superconducting NbN film. It is established that the optimum absorbed heterodyne power for the HEB mixer operating at 2.5 THz is about 100 nW. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1063-7850 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1389 |
Permanent link to this record |
|
|
|
Author |
Братман, В.Л.; Литвак, А.Г.; Суворов, Е.В. |
Title |
Освоение терагерцевого диапазона: источники и приложения |
Type |
Journal Article |
Year |
2010 |
Publication |
Успехи физических наук |
Abbreviated Journal |
Успехи физ. наук |
Volume |
181 |
Issue |
8 |
Pages |
867–874 |
Keywords |
HEB |
Abstract |
|
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
RPLAB @ gujma @ |
Serial |
674 |
Permanent link to this record |
|
|
|
Author |
Korneev, A.; Finkel, M.; Maslennikov, S.; Korneeva, Yu.; Florya, I.; Tarkhov, M.; Elezov, M.; Ryabchun, S.; Tretyakov, I.; Isupova, A.; Voronov, B.; Goltsman, G. |
Title |
Superconducting NbN terahertz detectors and infrared photon counters |
Type |
Journal Article |
Year |
2010 |
Publication |
Вестник НГУ. Серия: физ. |
Abbreviated Journal |
Вестник НГУ. Серия: физ. |
Volume |
5 |
Issue |
4 |
Pages |
68-72 |
Keywords |
HEB; HEB mixer |
Abstract |
We present our recent achievements in the development of sensitive and ultrafast thin-film superconducting sensors: hot-electron bolometers (HEB), HEB-mixers for terahertz range and infrared single-photon counters. These sensors have already demonstrated a performance that makes them devices-of-choice for many terahertz and optical applications. Keywords: Hot electron bolometer mixers, infrared single-photon detectors, superconducting device fabrication, superconducting NbN films. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1818-7994 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
УДК 538.9 |
Approved |
no |
Call Number |
RPLAB @ gujma @ |
Serial |
708 |
Permanent link to this record |
|
|
|
Author |
Lobanov, Y. V.; Tong, Cheuk-Yu E.; Hedden, A. S.; Blundell, R.; Gol'tsman, G. N. |
Title |
Microwave-assisted슠measurement슠of the슠frequency슠response슠of슠terahertz슠HEB슠mixers슠with a슠fourier슠transform슠spectrometer |
Type |
Conference Article |
Year |
2010 |
Publication |
21st International Symposium on Space Terahertz Technology |
Abbreviated Journal |
21st ISSTT |
Volume |
|
Issue |
|
Pages |
420-423 |
Keywords |
HEB mixer |
Abstract |
We describe a novel method of operation of the HEB direct detector for use with a Fourier Transform Spectrometer. Instead of elevating the bath temperature, we have measured the RF response of waveguide HEB mixers by applying microwave radiation to select appropriate bias conditions. In our experiment, a microwave signal is injected into the HEB mixer via its IF port. By choosing an appropriate injection level, the device can be operated close to the desired operating point. Furthermore, we have shown that both thermal biasing and microwave injection can reproduce the same spectral response of the HEB mixer. However, with the use of microwave injection, there is no need to wait for the mixer to reach thermal equilibrium, so characterisation can be done in less time. Also, the liquid helium consumption for our wet cryostat is also reduced. We have demonstrated that the signalto-noise ratio of the FTS measurements can be improved with microwave injection. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
RPLAB @ gujma @ |
Serial |
725 |
Permanent link to this record |
|
|
|
Author |
Ozhegov, R. V.; Gorshkov, K. N.; Okunev, O. V.; Gol’tsman, G. N. |
Title |
Superconducting hot-electron bolometer mixer as element of thermal imager matrix |
Type |
Journal Article |
Year |
2010 |
Publication |
Tech. Phys. Lett. |
Abbreviated Journal |
Tech. Phys. Lett. |
Volume |
36 |
Issue |
11 |
Pages |
1006-1008 |
Keywords |
HEB mixers |
Abstract |
The possibility of using a matrix of sensitive elements on a 12-mm-diameter hyperhemispherical lens in a thermal imager operating in the terahertz range has been studied. Dimensions of a lens region acceptable for arrangement of the matrix, in which the receiver noise temperature varies within 16% of the mean value, are determined to be 3.3% of the lens diameter. Deviations of the main lobe of the directivity pattern are evaluated, which amount to ±1.25° relative to the direction toward the optimum position of a mixer. The fluctuation sensitivity of the receiver measured in experiment is 0.5 K at a frequency of 300 GHz. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1063-7850 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1390 |
Permanent link to this record |
|
|
|
Author |
Palma, F.; Teppe, F.; Fatimy, A. E.; Green, R.; Xu, J.; Vachontin, Y.; Tredicucci, A.; Goltsman, G.; Knap, W. |
Title |
THz communication system based on a THz quantum cascade laser and a hot electron bolometer |
Type |
Conference Article |
Year |
2010 |
Publication |
35th Int. Conf. Infrared, Millimeter, and Terahertz Waves |
Abbreviated Journal |
35th Int. Conf. Infrared, Millimeter, and Terahertz Waves |
Volume |
|
Issue |
|
Pages |
11623798 (1 to 2) |
Keywords |
QCL, HEB detector |
Abstract |
We present the experimental study of the direct emission – detection system based on the THz Quantum Cascade Laser as a source and Hot Electron Bolometer (HEB) detector – in view of its application as an optical communication system. We show that the system can efficiently transmit the QCL Terahertz pulses. We estimate the maximal modulation speed of the system to be about several GHz and show that it is limited only by the QCL pulse power supply, detector amplifier and connection line/wires parameters. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1391 |
Permanent link to this record |
|
|
|
Author |
Smirnov, K. V.; Vakhtomin, Yu. B.; Divochiy, A. V.; Ozhegov, R. V.; Pentin, I. V.; Gol'tsman, G. N. |
Title |
Infrared and terahertz detectors on basis of superconducting nanostructures |
Type |
Conference Article |
Year |
2010 |
Publication |
Microwave and Telecom. Technol. (CriMiCo), 20th Int. Crimean Conf. |
Abbreviated Journal |
|
Volume |
|
Issue |
|
Pages |
823-824 |
Keywords |
SSPD, SNSPD, HEB |
Abstract |
Results of development of single-photon receiving systems of visible, infrared and terahertz range based on thin-film superconducting nanostructures are presented. The receiving systems are produced on the basis of superconducting nanostructures, which function by means of hot-electron phenomena. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
IEEE |
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
RPLAB @ sasha @ smirnov2010infrared |
Serial |
1025 |
Permanent link to this record |