|
Gol'tsman GN, Elant'iev AI, Karasik BS, Gershenzon EM. Antenna – coupled superconducting electron-heating bolometer. In: Proc. 4th Int. Symp. Space Terahertz Technol.; 1993. p. 623–8.
Abstract: We propose a novel antenna-coupled superconducting bolometer based on electron-heating in the resistive state. A short narrow ultrathin super- conducting film strip (sized approximately 4x1x0.01 pm 3 ), which is in good thermal contact with the thermostat, serves as a resistive load for infrared or submillimeter current. In contrast to conventional isothermal super- conducting bolometers electron-heating ones can have a higher sensitivity which grows when filni. thickness is reduced. Response time of electron- heating bolometer does not depend on heat transfer from the film to the enviroment. To calculate the sensitivity (NEP), we have used experimental data on wideband Al, Nb and NbN bolometers which have the same un- derlying physical mechanism. The bolom.eters have been made in the form of a structure composed of a number of long narrow strips. The values of for Al, NEP have been found to be 1.5 . 113 -16 1 140 -15 ) and 2 . 10 – 14werT,-1/2 – Nb and NbN respectively. In the paper, the prospects are also discussed of improving the picosecond YBaCuO detector, developed recently. NEP value of the detector, if combined with a microantenna, can reach the order of 10- •ilz-v2.
|
|
|
Nebosis RS, Steinke R, Lang PT, Schatz W, Heusinger MA, Renk KF, et al. Picosecond YBa2Cu3O7−δdetector for far‐infrared radiation. J Appl Phys. 1992;72(11):5496–9.
Abstract: We report on a picosecond YBa2Cu3O7−δ detector for far‐infrared radiation. The detector, consisting of a current carrying structure cooled to liquid‐nitrogen temperature, was studied by use of ultrashort laser pulses from an optically pumped far‐infrared laser in the frequency range from 25 to 215 cm−1. We found that the sensitivity (1 mV/W) was almost constant in this frequency range. We estimated a noise equivalent power of less than 5×10−7 W Hz−1/2. Taking into account the results of a mixing experiment (in the frequency range from 4 to 30 cm−1) we suggest that the response time of the detector was few picoseconds.
|
|
|
Karasik BS, Zorin MA, Milostnaya II, Elantev AI, Gol’tsman GN, Gershenzon EM. Evidence of subnanosecond transition stage in S-N current switching of YBaCuO films. In: Buhrman RA, Clarke JT, Daly K, Koch RH, Luine JA, Simon RW, editors. Proc. SPIE. Vol 2160. SPIE; 1994. p. 74–82.
Abstract: We report on a study of S-N and N-S current switching in high quality YBaCuO films deposited onto ZrO2 and NdGaO3 substrates. The films 60-120 nm thick prepared by laser ablation were structured into single strips and were provided with gold contacts. We monitored the time dependence of the resistance upon application of the voltage step on the film. Experiment performed within certain ranges of voltage amplitudes and temperatures showed the occurrence of the fast stage both in S-N (shorter than 300 ps) and N-S transition. We discuss the mechanism of switching taking into account the hot electron phenomena in YBaCuO. The contributions of various thermal processes in the subsequent stage of the resistance dynamic are also discussed. The basic limiting characteristics (average dissipated power, minimum work done for switching, maximum repetition rate) of a picosecond switch which is proposed to be developed are estimated.
|
|
|
Gousev YP, Gol'tsman GN, Karasik BS, Gershenzon EM, Semenov AD, Barowski HS, et al. Quasioptical superconducting hot electron bolometer for submillmeter waves. Int J of Infrared and Millimeter Waves. 1996;17(2):317–31.
Abstract: We report on a superconducting hot electron bolometer coupled to radiation via a broadband antenna. The bolometer, a structured NbN film, was patterned on a thin dielectric membrane between terminals of a gold slotline antenna. We investigated the response to submillimeter radiation (wave-lengths ∼ 0.1 mm to 0.7 mm) in the fundamental Gaussian mode. We found that the directivity of the antenna was constant within a factor of 2.5 through the whole experimental range. The noise equivalent power of the bolometer at 119 µm was ∼ 3 · 10−13 W/Hz1/2; a time constant of ∼ 160 ps was estimated.
|
|
|
Gousev YP, Olsson HK, Gol'tsman GN, Voronov BM, Gershenzon EM. NbN hot-electron mixer at radiation frequencies between 0.9 THz and 1.2 THz. In: Proc. 9th Int. Symp. Space Terahertz Technol.; 1998. p. 121–9.
Abstract: We report on noise temperature measurements for a NbN phonon-cooled hot-electron mixer at radiation frequencies between 0.9 THz and 1.2 THz. Radiation was coupled to the mixer, placed in a vacuum chamber of He cryostat, by means of a planar spiral antenna and a Si immersion lens. A backward-wave oscillator, tunable throughout the spectral range, delivered an output power of few 1.1W that was enough for optimum operation of the mixer. At 4.2 K ambient temperature and 1.025 THz radiation frequency, we obtained a receiver noise temperature of 1550 K despite of using a relatively noisy room-temperature amplifier at the intermediate frequency port. The noise temperature was fairly constant throughout the entire operation range and for intermediate frequencies from 1 GHz to 2 GHz.
|
|
|
Semenov AD, Gousev YP, Nebosis RS, Renk KF, Yagoubov P, Voronov BM, et al. Heterodyne detection of THz radiation with a superconducting hot‐electron bolometer mixer. Appl Phys Lett. 1996;69(2):260–2.
Abstract: We report on the use of a superconducting hot‐electron bolometer mixer for heterodyne detection of terahertz radiation. Radiation with a wavelength of 119 μm was coupled to the mixer, a NbN microbridge, by a hybrid quasioptical antenna consisting of an extended hyperhemispherical lens and a planar logarithmic spiral antenna. We found, at an intermediate frequency of 1.5 GHz, a system double side band noise temperature of ≊40 000 K and conversion losses of 25 dB. We also discuss the possibilities of further improvement of the mixer performance.
|
|
|
Nebosis RS, Heusinger MA, Semenov AD, Lang PT, Schatz W, Steinke R, et al. Ultrafast photoresponse of an YBa2Cu3O7-δ film to far-infrared radiation pulses. Opt Lett. 1993;18(2):96–7.
Abstract: We report the observation of an ultrafast photoresponse of a high-T(c), film to far-infrared radiation pulses. The response of a sample, consisting of a current-carrying structured YBa(2)Cu(3)O(7-delta) film cooled to liquid-nitrogen temperature, was studied by use of ultrashort laser pulses from an optically pumped far-infrared laser in the frequency range from 0.7 to 7 THz. We found that the response time was limited by the time resolution, 120 ps, of our electronic registration equipment.
|
|
|
Il'in KS, Lindgren M, Currie MA, Semenov D, Gol'tsman GN, Sobolewski R, et al. Picosecond hot-electron energy relaxation in NbN superconducting photodetectors. Appl Phys Lett. 2000;76(19):2752–4.
Abstract: We report time-resolved characterization of superconducting NbN hot-electron photodetectors using an electro-optic sampling method. Our samples were patterned into micron-size microbridges from 3.5-nm-thick NbN films deposited on sapphire substrates. The devices were illuminated with 100 fs optical pulses, and the photoresponse was measured in the ambient temperature range between 2.15 and 10.6 K (superconducting temperature transition TC). The experimental data agreed very well with the nonequilibrium hot-electron, two-temperature model. The quasiparticle thermalization time was ambient temperature independent and was measured to be 6.5 ps. The inelastic electron–phonon scattering time Ï„e–ph tended to decrease with the temperature increase, although its change remained within the experimental error, while the phonon escape time Ï„es decreased almost by a factor of two when the sample was put in direct contact with superfluid helium. Specifically, Ï„e–ph and Ï„es, fitted by the two-temperature model, were equal to 11.6 and 21 ps at 2.15 K, and 10(±2) and 38 ps at 10.5 K, respectively. The obtained value of Ï„e–ph shows that the maximum intermediate frequency bandwidth of NbN hot-electron phonon-cooled mixers operating at TC can reach 16(+4/–3) GHz if one eliminates the bolometric phonon-heating effect.
|
|
|
Voevodin EI, Gershenzon EM, Goltsman GN, Ptitsina NG. Energy-spectrum of shallow acceptors in Ge deformed strongly by a uniaxial pressure. Sov Phys and Technics of Semiconductors. 1989;23(8):843–6.
Abstract: Проведены исследования спектров фототермической ионизации мелких акцепторов (В, Аl) в Ge, предельно сжатом вдоль кристаллографической оси [100]. Из данных измерений с учетом теории построен энергетический спектр примесей. Показано, что энергии большого числа уровней четных и нечетных состояний хорошо соответствуют расчету, выполненному для примесей в анизотропном полупроводнике с параметром анизотропии γ=m∗⊥/m∗∥>1.
|
|
|
Gershenzon EM, Goltsman GN, Semenov AD, Sergeev AV. Limiting characteristic of fast superconducting bolometers. Sov Phys-Tech Phys. 1989;34:195–9.
Abstract: Теоретически и экспериментально исследовано физическое ограничение быстродействия сверхпроводящего болометра. Показано, что минимальная постоянная времени реализуется в условиях электронного разогрева и определяется процессом неупругого электрон-фонон- ного взаимодействия. Сформулированы требования кконструкции «электронного болометра» для достижения предельной чувствительности. Проведено сравнение характеристик электронного болометра и обычных болометров различных типов.
|
|