Lobanov YV, Tong C-YE, Hedden AS, Blundell R, Gol'tsman GN. Microwave-assisted슠measurement슠of the슠frequency슠response슠of슠terahertz슠HEB슠mixers슠with a슠fourier슠transform슠spectrometer. In: 21st International Symposium on Space Terahertz Technology.; 2010. p. 420–3.
Abstract: We describe a novel method of operation of the HEB direct detector for use with a Fourier Transform Spectrometer. Instead of elevating the bath temperature, we have measured the RF response of waveguide HEB mixers by applying microwave radiation to select appropriate bias conditions. In our experiment, a microwave signal is injected into the HEB mixer via its IF port. By choosing an appropriate injection level, the device can be operated close to the desired operating point. Furthermore, we have shown that both thermal biasing and microwave injection can reproduce the same spectral response of the HEB mixer. However, with the use of microwave injection, there is no need to wait for the mixer to reach thermal equilibrium, so characterisation can be done in less time. Also, the liquid helium consumption for our wet cryostat is also reduced. We have demonstrated that the signalto-noise ratio of the FTS measurements can be improved with microwave injection.
|
|
|
Lobanov YV, Tong C-yu E, Hedden AS, Blundell R, Gol’tsman GN. Microwave-assisted measurement of the frequency response of terahertz HEB mixers with a Fourier transform spectrometer. In: Proc. 21th Int. Symp. Space Terahertz Technol.; 2010. p. 420–3.
Abstract: We describe a novel method of operation of the HEB direct detector for use with a Fourier Transform Spectrometer. Instead of elevating the bath temperature, we have measured the RF response of waveguide HEB mixers by applying microwave radiation to select appropriate bias conditions. In our experiment, a microwave signal is injected into the HEB mixer via its IF port. By choosing an appropriate injection level, the device can be operated close to the desired operating point. Furthermore, we have shown that both thermal biasing and microwave injection can reproduce the same spectral response of the HEB mixer. However, with the use of microwave injection, there is no need to wait for the mixer to reach thermal equilibrium, so characterisation can be done in less time. Also, the liquid helium consumption for our wet cryostat is also reduced. We have demonstrated that the signal- to-noise ratio of the FTS measurements can be improved with microwave injection.
|
|
|
Gershenzon EM, Gol'tsman GN, Elantiev AI, Karasik BS, Potoskuev SE. Intense electromagnetic radiation heating of electrons of a superconductor in the resistive state. Sov J Low Temp Phys. 1988;14(7):414–20.
|
|
|
Hajenius M, Baselmans JJA, Gao JR, Klapwijk TM, de Korte PAJ, Voronov B, et al. Improved NbN phonon cooled hot electron bolometer mixers. In: Proc. 14th Int. Symp. Space Terahertz Technol. Tucson, USA; 2003. p. 413–23.
Abstract: NbN phonon-cooled hot electron bolometer mixers (HEBs) have been realized with negligible contact resistance to Au pads. By adding either a 5 nm Nb or a 10 nm NbTiN layer between the Au and NbN, to preserve superconductivity in the NbN under the Au contact pad, superior noise temperatures have been obtained. Using DC I,V curves and resistive transitions in combination with process parameters we analyze the nature of these improved devices and determine interface transparencies.
|
|
|
Huebers H-W, Schubert J, Semenov A, Gol’tsman GN, Voronov BM, Gershenzon EM, et al. NbN phonon-cooled hot-electron bolometer as a mixer for THz heterodyne receivers. In: Chamberlain JM, editor. Proc. SPIE. Vol 3828. Spie; 1999. p. 410–6.
Abstract: We have investigated a phonon-cooled NbN hot electron bolometric (HEB) mixer in the frequency range from 0.7 THz to 5.2 THz. The device was a 3.5 nm thin film with an in- plane dimension of 1.7 X 0.2 micrometers 2 integrated in a complementary logarithmic spiral antenna. The measured DSB receiver noise temperatures are 1500 K, 2200 K, 2600 K, 2900 K, 4000 K, 5600 K and 8800 K. The sensitivity fluctuation, the long term stability, and the antenna pattern were measured and the suitability of the mixer for a practical heterodyne receiver is discussed.
|
|
|
Симонов НО, Флоря ИН, Корнеева ЮП, Корнеев АА, Гольцман ГН. Однофотонный отклик в тонких сверхпроводящих MoNx пленках. In: Сборн. науч. труд. VII международн. конф. по фотонике и информац. опт.; 2018. p. 408–9.
Abstract: Продемонстрирован однофотонный отклик, при токе близком к критическому, в MoNx сверхпроводящих полосках шириной 70-104 нм. MoNx детекторы, имеющие коэффициент диффузии D≈0.32 см2/с и время электрон-фононного взаимодействия ηe-ph≈300 пс, достигают квантовой эффективности QE≈20% на длине волны λ=1550 нм. Возможность реализации однофотонного детектора в данном материале, подтверждает существующую теорию вихревого механизма возникновения фотоотклика в узких сверхпроводящих полосках.
|
|
|
Boyarskii DA, Gershenzon VE, Gershenzon EM, Gol'tsman GN, Ptitsina NG, Tikhonov VV, et al. On the possibility of determining the microstructural parameters of an oil-bearing layer from radiophysical measurement data. J of Communications Technology and Electronics. 1996;41(5):408–14.
Abstract: A method for the reconstruction of microstructural properties of an oil-bearing rock from the spectral dependence of the transmission factor of submillimeter waves is proposed.
|
|
|
Kroug M, Yagoubov P, Gol'tsman G, Kollberg E. NbN quasioptical phonon cooled hot electron bolometric mixers at THz frequencies. In: Inst. Phys. Conf. Ser. Vol 1. Bristol; 1997. p. 405–8.
|
|
|
Smirnov KV, Vachtomin YB, Antipov SV, Maslennikov SN, Kaurova NS, Drakinsky VN, et al. Noise and gain performance of spiral antenna coupled HEB mixers at 0.7 THz and 2.5 THz. In: Proc. 14th Int. Symp. Space Terahertz Technol.; 2003. p. 405–12.
Abstract: Noise and gain performance of hot electron bolometer (HEB) mixers based on ultrathin superconducting NbN films integrated with a spiral antenna was studied. The noise temperature measurements for two samples with different active area of 3 p.m x 0.24 .tni and 1.3 1..tm x 0.12 1.tm were performed at frequencies 0.7 THz and 2.5 THz. The best receiver noise temperatures 370 K and 1600 K, respectively, have been found at these frequencies. The influence of contact resistance between the superconductor and the antenna terminals on the noise temperature of HEB is discussed. The noise and gain bandwidth of 5GHz and 4.2 GHz, respectively, are demonstrated for similar HEB mixer at 0.75 THz.
|
|
|
Sergeev AV, Aksaev EE, Gogidze IG, Gol’tsman GN, Semenov AD, Gershenzon EM. Thermal boundary resistance at YBaCuO film-substrate interface. In: Meissner M, Pohl RO, editors. Phonon Scattering in Condensed Matter VII. Springer Series in Solid-State Sciences. Vol 112.; 1993. p. 405–6.
Abstract: The nanosecond voltage response of YBaCuo films on Al2O3, MgO and ZrO2 substrates to electromagnetic radiation of millimeter and visible ranges has been investigated. The analysis of experimental conditions for Al2O3 and MgO substrates shows that the resistance change is monitored by the Kapitza boundary shift of temperature during the temporal interval ~ 100 ns limited by the time of phonon return from a substrate into a film. The observed exponential voltage decay is described by the phonon escape time which is proportional to the film thickness and is weakly temperature dependent.
|
|