|
Casaburi A, Ejrnaes M, Quaranta O, Gaggero A, Mattioli F, Leoni R, et al. Experimental characterization of NbN nanowire optical detectors with parallel stripline configuration. In: J. Phys.: Conf. Ser. Vol 97. IOP Publishing; 2008. 012265 (1 to 6).
Abstract: We have developed a novel geometrical configuration for NbN-based superconducting single photon optical detector (SSPD) that achieves two goals: a much lower intrinsic impedance, and a consequently greater bandwidth, and a much larger signal amplitude compared to the standard meandered configuration. This has been obtained by implementing a properly designed parallel stripline structure where a cascade switching mechanism occurs when one of the striplines is hit by an optical photon. The overall switching occurs synchronously and in a very short time, giving rise to a strong and fast voltage pulse. The SSPD have been realized using state of the art NbN deposition technology and e-beam lithography. The strips are 100 nm wide and 5 μm long and have been realized with 4 nm NbN film on sapphire and Si substrate. We report on experimental characterization of such novel devices. The performances of the proposed novel type of SSPD are compared with standard SSPD design and results in terms of signal amplitude, risetime and effective detection area.
|
|
|
Slysz W, Wegrzecki M, Bar J, Grabiec P, Gol'tsman GN, Verevkin M, et al. NbN superconducting single-photon detectors coupled with a communication fiber. Vol 37.; 2004.
|
|
|
Slysz W, Wegrzecki M, Papis E, Gol'tsman GN, Verevkin A, Sobolewski R. A method of optimization of the NbN superconducting single-photon detector. Vol 36.; 2004.
|
|
|
Gershenzon EM, Gol'tsman GN. Effect of electromagnetic radiation on a superconductor in a magnetic field. In: Izv. Akad. Nauk SSSR, Seriya Fizicheskaya. Vol 52.; 1988. p. 449–51.
Abstract: The effect of electromagnetic radiation on thin superconducting films of Nb with a large number of static defects is investigated experimentally for the case where the film is in the resistive state due to an applied magnetic field and transport current. The results obtained are found to be well described by a model of spatially homogeneous electron heating. It is noted that the results obtained here for Nb films are also valid for Al, NbN, and MoRe films.
|
|
|
Yagoubov P, Kroug M, Merkel H, Kollberg E, Schubert J, Hubers HW, et al. Hot electron bolometric mixers based on NbN films deposited on MgO substrates. In: Inst. Phys. Conf. Ser. Vol 167. Barcelona, Spain; 1999. p. 687–90.
|
|
|
Schubert J, Semenov A, Hübers H-W, Gol'tsman G, Schwaab G, Voronov B, et al. Broad-band terahertz NbN hot-electron bolometric mixer. In: Inst. Phys. Conf. Vol 167.; 1999. p. 663–6.
|
|
|
Kroug M, Yagoubov P, Gol'tsman G, Kollberg E. NbN quasioptical phonon cooled hot electron bolometric mixers at THz frequencies. In: Inst. Phys. Conf. Ser. Vol 1. Bristol; 1997. p. 405–8.
|
|
|
Cherednichenko S, Yagoubov P, Il'in K, Gol'tsman G, Gershenzon E. Large bandwidth of NbN phonon-cooled hot-electron bolometer mixers. In: Proc. 27th Eur. Microwave Conf. Vol 2. IEEE; 1997. p. 972–7.
Abstract: The bandwidth of NbN phonon-cooled hot electron bolometer mixers has been systematically investigated with respect to the film thickness and film quality variation. The films, 2.5 to 10 nm thick, were fabricated on sapphire substrates using DC reactive magnetron sputtering. All devices consisted of several parallel strips, each 1 um wide and 2 um long, placed between Ti-Au contact pads. To measure the gain bandwidth we used two identical BWOs operating in the 120-140 GHz frequency range, one functioning as a local oscillator and the other as a signal source. The majority of the measurements were made at an ambient temperature of 4.2 K with optimal LO and DC bias. The maximum 3 dB bandwidth (about 4 GHz) was achieved for the devices made of films which were 2.5-3.5 nm thick, had a high critical temperature, and high critical current density. A theoretical analysis of bandwidth for these mixers based on the two-temperature model gives a good description of the experimental results if one assumes that the electron temperature is equal to the critical temperature.
|
|
|
Semenov AD, Sergeev AV, Kouminov P, Goghidze IG, Heusinger MA, Nebosis RS, et al. Transparency of YBCO film/substrate interfaces for thermal phonons determined by photoresponse measurements. In: Freyhardt HC, editor. Proc. 1st European Conf. on Appl. Supercond. Vol 2.; 1993. p. 1443–6.
Abstract: Direct measurements of the thermal boundary resistance were performed by means of the stationary method. In this approach the temperature of an electrically heated film is controlled by its dc resistance while an additional film on the same substrate is used as a thermometer monitoring substrate temperature. The temperature field in the substrate is then calculated to deduce the Kapitza temperature step at the interface between the heated strip and the substrate. The main statement of all afore-said papers is that experimental values of the thermal boundary resistance are too large to be explained by the acoustic mismatch model. In this paper we investigate transparency of YBaCuO film/substrate interfaces for thermal phonons by means of photoresponse measurements. We show that our data are in reasonable agreement with the acoustic mismatch theory.
|
|
|
Danerud M, Winkler D, Zorin M, Trifonov V, Karasik B, Gershenzon EM, et al. Picosecond detection of infrared radiation with YBa2Cu3O7-δ thin films. In: Birch JR, Parker TJ, editors. Proc. SPIE. Vol 2104. Spie; 1993. p. 183–4.
Abstract: Picosecond nonequilibrium and slow bolometric responses from a patterned high-Tc superconducting (HTS) film due toinfrared radiation were investigated using both modulation and pulse techniques. Measurements at A, = 0.85 [tm andA, = 10.6 lim have shown a similar behaviour of the response vs modulation frequency f. The responsivity of the HTS filmbased detector at f ..- 0.6-1 GHz is estimated to be 10-2 – 10-1 V/W.
|
|