|
Yang Y, Fedorov G, Shafranjuk SE, Klapwijk TM, Cooper BK, Lewis RM, et al. Electronic transport and possible superconductivity at Van Hove singularities in carbon nanotubes. Nano Lett. 2015;15(12):7859–66.
Abstract: Van Hove singularities (VHSs) are a hallmark of reduced dimensionality, leading to a divergent density of states in one and two dimensions and predictions of new electronic properties when the Fermi energy is close to these divergences. In carbon nanotubes, VHSs mark the onset of new subbands. They are elusive in standard electronic transport characterization measurements because they do not typically appear as notable features and therefore their effect on the nanotube conductance is largely unexplored. Here we report conductance measurements of carbon nanotubes where VHSs are clearly revealed by interference patterns of the electronic wave functions, showing both a sharp increase of quantum capacitance, and a sharp reduction of energy level spacing, consistent with an upsurge of density of states. At VHSs, we also measure an anomalous increase of conductance below a temperature of about 30 K. We argue that this transport feature is consistent with the formation of Cooper pairs in the nanotube.
|
|
|
Korneeva Y, Vodolazov D, Florya I, Manova N, Smirnov E, Korneev A, et al. Single photon detection in micron scale NbN and α-MoSi superconducting strips. In: EPJ Web Conf. Vol 190.; 2018. 04010 (1 to 2).
Abstract: We experimentally demonstrate the single photon detection in straight micrometer-wide NbN and α-MoSi bridges. Width of the bridges is 2 µm, while the wavelength of the photon changes from 408 to 1550 nm and critical current exceeds 50% of the depairing current. Obtained results offer the alternative route for design of detectors without resonator and meander structure and indirectly confirm vortex assisted mechanism of single photon detection.
|
|
|
Floet DW, Baselmans JJA, Klapwijk TM, Gao JR. Resistive transition of niobium superconducting hot-electron bolometer mixers. Appl Phys Lett. 1998;73(19):2826.
|
|
|
Ganzevles WFM, Gao JR, de Korte PAJ, Klapwijk TM. Direct response of microstrip line coupled Nb THz hot-electron bolometer mixers. Appl Phys Lett. 2001;79(15):2483–5.
|
|
|
Baselmans JJA, Hajenius M, Gao JR, Klapwijk TM, de Korte PAJ, Voronov B, et al. Doubling of sensitivity and bandwidth in phonon cooled hot electron bolometer mixers. Appl Phys Lett. 2004;84(11):1958–60.
Abstract: We demonstrate that the performance of NbN lattice cooled hot electron bolometer mixers depends strongly on the interface quality between the bolometer and the contact structure. We show experimentally that both the receiver noise temperature and the gain bandwidth can be improved by more than a factor of 2 by cleaning the interface and adding an additional superconducting interlayer to the contact pad. Using this we obtain a double sideband receiver noise temperature TN,DSB=950 K
at 2.5 THz and 4.3 K, uncorrected for losses in the optics. At the same bias point, we obtain an IF gain bandwidth of 6 GHz.
|
|
|
Baselmans JJA, Baryshev A, Reker SF, Hajenius M, Gao JR, Klapwijk TM, et al. Direct detection effect in small volume hot electron bolometer mixers. Appl Phys Lett. 2005;86(16):163503 (1 to 3).
Abstract: We measure the direct detection effect in a small volume (0.15μm×1μm×3.5nm)(0.15μm×1μm×3.5nm) quasioptical NbN phonon cooled hot electronbolometermixer at 1.6THz1.6THz. We find that the small signal sensitivity of the receiver is underestimated by 35% due to the direct detection effect and that the optimal operating point is shifted to higher bias voltages when using calibration loads of 300K300K and 77K77K. Using a 200GHz200GHzbandpass filter at 4.2K4.2K the direct detection effect virtually disappears. This has important implications for the calibration procedure of these receivers in real telescope systems.
|
|
|
Baselmans JJA, Baryshev A, Reker SF, Hajenius M, Gao JR, Klapwijk TM, et al. Influence of the direct response on the heterodyne sensitivity of hot electron bolometer mixers. J Appl Phys. 2006;100(8):084510 (1 to 7).
Abstract: We present a detailed experimental study of the direct detection effect in a small volume (0.15μm×1μm×3.5nm) quasioptical NbN phonon cooled hot electron bolometer mixer at 673GHz. We find that the small signal noise temperature, relevant for an astronomical observation, is 20% lower than the noise temperature obtained using 300 and 77K calibration loads. In a separate set of experiments we show that the direct detection effect is caused by a combination of bias current reduction when switching from the 77 to the 300K
load in combination with the bias current dependence of the receiver gain. The bias current dependence of the receiver gain is shown to be mainly caused by the current dependence of the mixer gain.
|
|
|
Kooi JW, Baselmans JJA, Baryshev A, Schieder R, Hajenius M, Gao JR, et al. Stability of heterodyne terahertz receivers. J Appl Phys. 2006;100(6):064904 (1 to 9).
Abstract: In this paper we discuss the stability of heterodyne terahertz receivers based on small volume NbN phonon cooled hot electron bolometers (HEBs). The stability of these receivers can be broken down in two parts: the intrinsic stability of the HEB mixer and the stability of the local oscillator (LO) signal injection scheme. Measurements show that the HEB mixer stability is limited by gain fluctuations with a 1∕f spectral distribution. In a 60MHz noise bandwidth this results in an Allan variance stability time of ∼0.3s. Measurement of the spectroscopic Allan variance between two intermediate frequency (IF) channels results in a much longer Allan variance stability time, i.e., 3s between a 2.5 and a 4.7GHz channel, and even longer for more closely spaced channels. This implies that the HEB mixer 1∕f noise is strongly correlated across the IF band and that the correlation gets stronger the closer the IF channels are spaced. In the second part of the paper we discuss atmospheric and mechanical system stability requirements on the LO-mixer cavity path length. We calculate the mixer output noise fluctuations as a result of small perturbations of the LO-mixer standing wave, and find very stringent mechanical and atmospheric tolerance requirements for receivers operating at terahertz frequencies.
|
|
|
Hajenius M, Baselmans JJA, Baryshev A, Gao JR, Klapwijk TM, Kooi JW, et al. Full characterization and analysis of a terahertz heterodyne receiver based on a NbN hot electron bolometer. J. Appl. Phys.. 2006;100(7):074507.
|
|
|
Kooi JW, Baselmans JJA, Hajenius M, Gao JR, Klapwijk TM, Dieleman P, et al. IF impedance and mixer gain of NbN hot electron bolometers. J. Appl. Phys.. 2007;101(4):044511.
|
|