Lobanov YV, Vakhtomin YB, Pentin IV, Khabibullin RA, Shchavruk NV, Smirnov KV, et al. Characterization of the THz quantum cascade laser using fast superconducting hot electron bolometer. EPJ Web Conf. 2018;195:04004 (1 to 2).
|
|
|
Schroeder E, Mauskopf P, Pilyavsky G, Sinclair A, Smith N, Bryan S, et al. On the measurement of intensity correlations from laboratory and astronomical sources with SPADs and SNSPDs. In: Malbet F, Creech-Eakman MJ, Tuthill PG, editors. Proc. SPIE. Vol 9907. SPIE; 2016. 99070P (1 to 13).
Abstract: We describe the performance of detector modules containing silicon single photon avalanche photodiodes (SPADs) and superconducting nanowire single photon detectors (SNSPDs) to be used for intensity interferometry. The SPADs are mounted in fiber-coupled and free-space coupled packages. The SNSPDs are mounted in a small liquid helium cryostat coupled to single mode fiber optic cables which pass through a hermetic feed-through. The detectors are read out with microwave amplifiers and FPGA-based coincidence electronics. We present progress on measurements of intensity correlations from incoherent sources including gas-discharge lamps and stars with these detectors. From the measured laboratory performance of the correlation system, we estimate the sensitivity to intensity correlations from stars using commercial telescopes and larger existing research telescopes.
|
|
|
Shcheslavskiy V, Morozov P, Divochiy A, Vakhtomin Y, Smirnov K, Becker W. Erratum: “Ultrafast time measurements by time-correlated single photon counting coupled with superconducting single photon detector” [Rev. Sci. Instrum. 87, 053117 (2016)]. Vol 87.; 2016.
Abstract: In the original paper1the Ref. 10 should be M. Sanzaro, N. Calandri, A. Ruggeri, C. Scarcella, G. Boso, M. Buttafava, and A. Tosi, Proc. SPIE9370, 93701T (2015).
|
|
|
Smirnov K, Vachtomin Y, Divochiy A, Antipov A, Goltsman G. The limitation of noise equivalent power by background radiation for infrared superconducting single photon detectors coupled to standard single mode optical fibers. Rus J Radio Electron. 2015;(5).
Abstract: We investigated the minimum level of the dark count rates and noise equivalent power of superconducting single photon detectors coupled to standard single mode optical fibers. We found that background radiation limits the minimum level of the dark count rates. We also proposed the effective method for reducing background radiation out of the required spectral range of the detector. Measured noise equivalent power of detector reaches 8.9×10-19 W×Hz1/2 at a wavelength of 1.55 μm and quantum efficiency 35%.
|
|
|
Smirnov AV, Karmantsov MS, Smirnov KV, Vakhtomin YB, Masterov DV, Tarkhov MA, et al. Terahertz response of thin-film YBCO bolometers. Tech Phys. 2012;57(12):1716–9.
Abstract: The bolometric response of high-temperature thin-film YBCO superconducting detectors to an electromagnetic radiation with a frequency of 2.5 THz is measured for the first time. The minimum value of the noise-equivalent power of the detectors is 3.5 × 10−9 W/Hz−−−√. The feasibility of further increasing the sensitivity of the detectors is discussed.
|
|
|
Semenov AV, Devyatov IA, Korneev AA, Smirnov KV, Goltsman GN, Melnikov AP. Derivation of expression for thermodynamic potential of “dirty” superconductor. Rus J Radio Electron. 2012;(4).
Abstract: We derive a formula for thermodynamic potential of dirty superconductor which express it via isotropic quasiclassical Green functions of Usadel theory. Our result allows unify description of dynamic processes and fluctuations in superconducting nano-electronic devices.
|
|
|
Korneeva YP, Trifonov AV, Vakhtomin YB, Smirnov KV. Design of resonator for superconducting single-photon detector. Rus J Radio Electron. 2011;(12).
Abstract: A resonator for superconducting single-photon detector is designed. Near 60% coupling with a radiation propagating from a dielectric substrate of optical fiber is demonstrated to be achieved for typical values of the detector’s film sheet resistance.
|
|
|
Hübers H-W, Semenov A, Richter H, Birk M, Krocka M, Mair U, et al. Terahertz heterodyne receiver with a hot-electron bolometer mixer. In: Wold J, Davidson J, editors. Proc. Far-IR, Sub-mm, and mm Detector Technology Workshop.; 2002.
Abstract: During the past decade major advances have been made regarding low noise mixers for terahertz (THz) heterodyne receivers. State of the art hot-electron-bolometer (HEB) mixers have noise temperatures close to the quantum limit and require less than a µW power from the local oscillator (LO). The technology is now at a point where the performance of a practical receiver employing such mixer, rather than the figures of merit of the mixer itself, are of major concern. We have incorporated a phonon-cooled NbN HEB mixer in a 2.5 THz heterodyne receiver and investigated the performance of the receiver. This yields important information for the development of heterodyne receivers such as GREAT (German receiver for astronomy at THz frequencies aboard SOFIA)[1] and TELIS (Terahertz limb sounder), a balloon borne heterodyne receiver for atmospheric research [2]. Both are currently under development at DLR.
|
|
|
Semenov A, Richter H, Hübers H-W, Smirnov K, Voronov B, Gol'tsman G. Development of terahertz superconducting hot-electron bolometer mixers. In: Proc. 6th European Conf. Appl. Supercond. Vol 181.; 2003. p. 2960–5.
Abstract: We present recent results of the development of phonon cooled hot-electron bolometric (HEB) mixers for airborne and balloon borne terahertz heterodyne receivers. Three iomportant issues have been addresses: the quality of NbN films the HEB mixers were made from, the spectral properties of the HEB mixers and the local oscillator power required for optical operation. Studies with an atomic force microscope indicate, that the performance of the HEB mixer might have been effected by the microstructure of the NbN film. Antenna gain and noise temperature were investigated at terahertz frequencies for a HEB embedded in either log-spiral or twin-slot feed antenna. Comparison suggests that at frequencies above 3 THz the spiral feed provides better overall performance. At 1.6 THz, a power of 2.5 µW was required from the local oscillator for optimal operation of the HEB mixer.
|
|
|
Semenov AD, Hübers H-W, Gol’tsman GN, Smirnov K. Superconducting quantum detector for astronomy and X-ray spectroscopy. In: Pekola J, Ruggiero B, Silvestrini P, editors. Proc. Int. Workshop on Supercond. Nano-Electronics Devices. : Springer; 2002. p. 201–10.
Abstract: We propose the novel concept of ultra-sensitive energy-dispersive superconducting quantum detectors prospective for applications in astronomy and X-ray spectroscopy. Depending on the superconducting material and operation conditions, such detector may allow realizing background limited noise equivalent power 10−21 W Hz−1/2 in the terahertz range when exposed to 4-K background radiation or counting of 6-keV photon with almost 10—4 energy resolution. Planar layout and relatively simple technology favor integration of elementary detectors into a detector array.
|
|