|
Semenov AD, Hübers H–W, Schubert J, Gol'tsman GN, Elantiev AI, Voronov BM, et al. Frequency dependent noise temperature of the lattice cooled hot-electron terahertz mixer. In: Proc. 11th Int. Symp. Space Terahertz Technol.; 2000. p. 39–48.
Abstract: We present the measurements and the theoretical model on the frequency dependent noise temperature of a lattice cooled hot electron bolometer (HEB) mixer in the terahertz frequency range. The experimentally observed increase of the noise temperature with frequency is a cumulative effect of the non-uniform distribution of the high frequency current in the bolometer and the charge imbalance, which occurs near the edges of the normal domain and contacts with normal metal. In addition, we present experimental results which show that the noise temperature of a HEB mixer can be reduced by about 30% due to a Parylene antireflection coating on the Silicon hyperhemispheric lens.
|
|
|
Kroug M, Cherednichenko S, Merkel H, Kollberg E, Voronov B, Gol'tsman G, et al. NbN hot electron bolometric mixers for terahertz receivers. IEEE Trans Appl Supercond. 2001;11(1):962–5.
Abstract: Sensitivity and gain bandwidth measurements of phonon-cooled NbN superconducting hot-electron bolometer mixers are presented. The best receiver noise temperatures are: 700 K at 1.6 THz and 1100 K at 2.5 THz. Parylene as an antireflection coating on silicon has been investigated and used in the optics of the receiver. The dependence of the mixer gain bandwidth (GBW) on the bias voltage has been measured. Starting from low bias voltages, close to operating conditions yielding the lowest noise temperature, the GBW increases towards higher bias voltages, up to three times the initial value. The highest measured GBW is 9 GHz within the same bias range the noise temperature increases by a factor of two.
|
|
|
Gershenson ME, Gong D, Sato T, Karasik BS, Sergeev AV. Millisecond electron-phonon relaxation in ultrathin disordered metal films at millikelvin temperatures. Appl. Phys. Lett.. 2001;79:2049–51.
|
|
|
Cherednichenko S, Kroug M, Merkel H, Kollberg E, Loudkov D, Smirnov K, et al. Local oscillator power requirement and saturation effects in NbN HEB mixers. In: Jet Propulsion Laboratory CIit.u.t.e of T, editor. Proc. 12th Int. Symp. Space Terahertz Technol. San Diego, CA, USA; 2001. p. 273–85.
Abstract: The local oscillator power required for NbN hot-electron bolometric mixers (P LO ) was investigated with respect to mixer size, critical temperature and ambient temperature. P LO can be decreased by a factor of 10 as the mixer size decreases from 4×0.4 µm 2 to 0.6×0.13 µm 2 . For the smallest volume mixer the optimal local oscillator power was found to be 15 nW. We found that for such mixer no signal compression was observed up to an input signal of 2 nW which corresponds to an equivalent input load of 20,000 K. For a constant mixer volume, reduction of T c can decrease optimal local oscillator power at least by a factor of 2 without a deterioration of the receiver noise temperature. Bath temperature was found to have minor effect on the receiver characteristics.
|
|
|
Kroug M, Cherednichenko S, Choumas M, Merkel H, Kollberg E, Hübers H-W, et al. HEB quasi-optical heterodyne receiver for THz frequencies. In: Proc. 12th Int. Symp. Space Terahertz Technol. San Diego, CA, USA; 2001. p. 244–52.
|
|
|
Kawamura J, Hunter TR, Tong CYE, Blundell R, Papa DC, Patt F, et al. Ground-based terahertz CO spectroscopy towards Orion. A&A. 2002;394(1):271–4.
Abstract: Using a superconductive hot-electron bolometer heterodyne receiver on the 10-m Heinrich Hertz Telescope on Mount Graham, Arizona, we have obtained velocity-resolved 1.037 THz CO () spectra toward several positions along the Orion Molecular Cloud (OMC-1) ridge. We confirm the general results of prior observations of high-J CO lines that show that the high temperature, , high density molecular gas, , is quite extended, found along a ~ region centered on BN/KL. However, our observations have significantly improved angular resolution, and with a beam size of we are able to spatially and kinematically discriminate the emission originating in the extended quiescent ridge from the very strong and broadened emission originating in the compact molecular outflow. The ridge emission very close to the BN/KL region appears to originate from two distinct clouds along the line of sight with and ≈ . The former component dominates the emission to the south of BN/KL and the latter to the north, with a turnover point coincident with or near BN/KL. Our evidence precludes a simple rotation of the inner ridge and lends support to a model in which there are multiple molecular clouds along the line of sight towards the Orion ridge.
|
|
|
Maslennikov S, Antipov S, Shishkov A, Svechnikov S, Voronov B, Smirnov K, et al. NbN HEB mixer noise temperature measurements with hot/cold load mounted inside the helium cryostat at 300 GHz. In: Proc. Int. Student Seminar on Microwave Appl. of Novel Physical Phenomena supported by IEEE. St.-Petersburg: LETI; 2002.
|
|
|
Hübers H-W, Semenov AD, Richter H, Schubert J, Hadjiloucas S, Bowen JW, et al. Antenna pattern of the quasi-optical hot-electron bolometric mixer at terahertz frequencies. In: Proc. 12th Int. Symp. Space Terahertz Technol. San Diego, CA, USA; 2001. p. 286–96.
|
|
|
Ferrari S, Kovalyuk V, Hartmann W, Vetter A, Kahl O, Lee C, et al. Hot-spot relaxation time current dependence in niobium nitride waveguide-integrated superconducting nanowire single-photon detectors. Opt Express. 2017;25(8):8739–50.
Abstract: We investigate how the bias current affects the hot-spot relaxation dynamics in niobium nitride. We use for this purpose a near-infrared pump-probe technique on a waveguide-integrated superconducting nanowire single-photon detector driven in the two-photon regime. We observe a strong increase in the picosecond relaxation time for higher bias currents. A minimum relaxation time of (22 +/- 1)ps is obtained when applying a bias current of 50% of the switching current at 1.7 K bath temperature. We also propose a practical approach to accurately estimate the photon detection regimes based on the reconstruction of the measured detector tomography at different bias currents and for different illumination conditions.
|
|
|
Vahtomin YB, Finkel MI, Antipov SV, Voronov BM, Smirnov KV, Kaurova NS, et al. Gain bandwidth of phonon-cooled HEB mixer made of NbN thin film with MgO buffer layer on Si. In: Harvard university, editor. Proc. 13th Int. Symp. Space Terahertz Technol. Cambridge, MA, USA; 2002. p. 259–70.
Abstract: We present recently obtained values for gain bandwidth of NbN HEB mixers for different substrates and film thicknesses and for MgO buffer layer on Si at LO frequency of 0.85-1 THz. The maximal bandwidth, 5.2 GHz, was achieved for the device on MgO buffer layer on Si with a 2 nm thick NbN film. Functional devices based on NbN films of such thickness were fabricated for the first time due to an improvement of superconducting properties of NbN film deposited on MgO buffer layer on Si substrate.
|
|