|
Gershenzon EM, Goltsman GN, Orlov L. Investigation of population and ionization of donor excited states in Ge. In: Physics of Semiconductors. North-Holland Publishing Co.; 1976. p. 631–4.
|
|
|
Miller AJ, Lita AE, Calkins B, Vayshenker I, Gruber SM, Nam SW. Compact cryogenic self-aligning fiber-to-detector coupling with losses below one percent. Opt Express. 2011;19(10):9102–10.
Abstract: We present a compact packaging technique for coupling light from a single-mode telecommunication fiber to cryogenic single-photon sensitive devices. Our single-photon detectors are superconducting transition-edge sensors (TESs) with a collection area only a factor of a few larger than the area of the fiber core which presents significant challenges to low-loss fiber-to-detector coupling. The coupling method presented here has low loss, cryogenic compatibility, easy and reproducible assembly and low component cost. The system efficiency of the packaged single-photon counting detectors is verified by the “triplet method†of power-source calibration along with the “multiple attenuator†method that produces a calibrated single-photon flux. These calibration techniques, when used in combination with through-wafer imaging and fiber back-reflection measurements, give us confidence that we have achieved coupling losses below 1 % for all devices packaged according to the self-alignment method presented in this paper.
|
|
|
Gershenzon EM, Goltsman GN, Ptitsyna NG. Investigation of excited donor states in GaAs. Sov Phys Semicond. 1974;7(10):1248–50.
|
|
|
Gershenzon EM, Gol'tsman GN, Ptitsyna NG. Carrier lifetime in excited states of shallow impurities in germanium. JETP Lett. 1977;25(12):539–43.
|
|
|
Gorokhov G, Bychanok D, Gayduchenko I, Rogov Y, Zhukova E, Zhukov S, et al. THz spectroscopy as a versatile tool for filler distribution diagnostics in polymer nanocomposites. Polymers (Basel). 2020;12(12):3037 (1 to 14).
Abstract: Polymer composites containing nanocarbon fillers are under intensive investigation worldwide due to their remarkable electromagnetic properties distinguished not only by components as such, but the distribution and interaction of the fillers inside the polymer matrix. The theory herein reveals that a particular effect connected with the homogeneity of a composite manifests itself in the terahertz range. Transmission time-domain terahertz spectroscopy was applied to the investigation of nanocomposites obtained by co-extrusion of PLA polymer with additions of graphene nanoplatelets and multi-walled carbon nanotubes. The THz peak of permittivity's imaginary part predicted by the applied model was experimentally shown for GNP-containing composites both below and above the percolation threshold. The physical nature of the peak was explained by the impact on filler particles excluded from the percolation network due to the peculiarities of filler distribution. Terahertz spectroscopy as a versatile instrument of filler distribution diagnostics is discussed.
|
|
|
Prober DE. Superconducting terahertz mixer using a transition-edge microbolometer. Appl Phys Lett. 1993;62(17):2119–21.
|
|
|
Gershenzon EM, Gol'tsman GN. Transitions of electrons between excited states of donors in germanium. JETP Lett. 1971;14(2):63–5.
|
|
|
Hoevers HFC, Bento AC, Bruijn MP, Gottardi L, Korevaar MAN, Mels WA, et al. Thermal fluctuation noise in a voltage biased superconducting transition edge thermometer. Appl Phys Lett. 2000;77(26):4421–4.
Abstract: The current noise at the output of a microcalorimeter with a voltage biased superconducting transition edge thermometer is studied in detail. In addition to the two well-known noise sources: thermal fluctuation noise from the heat link to the bath and Johnson noise from the resistive thermometer, a third noise source strongly correlated with the steepness of the thermometer is required to fit the measured noise spectra. Thermal fluctuation noise, originating in the thermometer itself, fully explains the additional noise. A simple model provides quantitative agreement between the observed and calculated noise spectra for all bias points in the superconducting transition.
|
|
|
Galeazzi M. Fundamental noise processes in TES devices. IEEE Trans Appl Supercond. 2011;21(3):267–71.
Abstract: Microcalorimeters and bolometers are noise-limited devices, therefore, a proper understanding of all noise sources is essential to predict and interpret their performance. In this paper, I review the fundamental noise processes contributing to Transition Edge Sensor (TES) microcalorimeters and bolometers and their effect on device performance. In particular, I will start with a simple, monolithic device model, moving to a more complex one involving discrete components, to finally move to today's more realistic, comprehensive model. In addition to the basic noise contribution (equilibrium Johnson noise and phonon noise), TES are significantly affected by extra noise, which is commonly referred to as excess noise. Different fundamental processes have been proposed and investigated to explain the origin of this excess noise, in particular near equilibrium non-linear Johnson noise, flux-flow noise, and internal thermal fluctuation noise. Experimental evidence shows that all three processes are real and contribute, at different levels, to the TES noise, although different processes become important at different regimes. It is therefore time to discard the term “excess noise” and consider these terms part of the “fundamental noise processes” instead.
|
|
|
Gershenzon EM, Orlov LA, Ptitsina NG. Absorption spectra in electron transitions between excited states of impurities in germanium. JETP Lett. 1975;22(4):95–7.
|
|