|
Romanov NR, Zolotov PI, Vakhtomin YB, Divochiy AV, Smirnov KV. Electron diffusivity measurements of VN superconducting single-photon detectors. In: J. Phys.: Conf. Ser. Vol 1124.; 2018. 051032.
Abstract: The research of ultrathin vanadium nitride (VN) films as a promising candidate for superconducting single-photon detectors (SSPD) is presented. The electron diffusivity measurements are performed for such devices. Devices that were fabricated out from 9.9 nm films had diffusivity coefficient of 0.41 cm2/s and from 5.4 nm – 0.54 cm2/s. Obtained values are similar to other typical SSPD materials. The diffusivity that increases along with decreasing of the film thickness is expected to allow fabrication of the devices with improved characteristics. Fabricated VN SSPDs showed prominent single-photon response in the range 0.9-1.55 µm.
|
|
|
Zolotov PI, Divochiy AV, Vakhtomin YB, Morozov PV, Seleznev VA, Smirnov KV. Development of high-effective superconducting single-photon detectors aimed for mid-IR spectrum range. In: J. Phys.: Conf. Ser. Vol 917.; 2017. 062037.
Abstract: We report on development of superconducting single-photon detectors (SSPD) with high intrinsic quantum efficiency in the wavelength range 1.31 – 3.3 μm. By optimization of the NbN film thickness and its compound, we managed to improve detection efficiency of the detectors in the range up to 3.3 μm. Optimized devices showed intrinsic quantum efficiencies as high as 10% at mid-IR range.
|
|
|
Simonov NO, Korneeva YP, Korneev AA, Goltsman GN. Enhance of the superconducting properties of the NbN/Au bilayer bridges. In: J. Phys.: Conf. Ser. Vol 1695.; 2020. 012132 (1 to 4).
Abstract: We experimentally demonstrate strong temperature dependence of the critical current of the superconducting 600-nm-wide and 5-μm-long bridge made of NbN/Au bilayer. The result is achieved due to the proximity effect realized between the highly disordered superconducting NbN layer and low resistive normal-metal Au layer.
|
|
|
Elezov MS, Shcherbatenko ML, Sych DV, Goltsman GN. Development of control method for an optimal quantum receiver. In: J. Phys.: Conf. Ser. Vol 1695.; 2020. 012126.
Abstract: We propose a method for optimal displacement controlling of an optimal quantum receiver for registrations a binary coherent signal. An optimal receiver is able to distinguish between two phase-modulated states of a coherent signal. The optimal receiver controlling method can be used later in practice in various physical implementations of the optimal receiver.
|
|
|
Shcherbatenko M, Elezov M, Sych D, Goltsman GN. Optimal fiber optic scheme for sub-SQL quantum receiver realization. In: J. Phys.: Conf. Ser. Vol 1695.; 2020. 012140.
Abstract: Practical implementation of high-precision quantum measurements is an important problem in modern science. One of the main parts of the quantum receiver is the optical scheme. We developed and tested several optical circuits based on different types of interferometers, namely Sagnac-based scheme, Mach-Zehnder-based scheme, and Michelson-based scheme. All these schemes are assembled with optical fibers and fiber-optic components, since the fiber-optic implementation is closest to application in practical devices. Schemes were evaluated according to two main criteria: extinction and interference stability. On the basis of the obtained data, it can be concluded that the most suitable is the scheme based on the Mach-Zehnder interferometer. In continuous mode, we were able to obtain an interference extinction about 30 dB with acceptable temporal stability.
|
|
|
Titova N, Gayduchenko IA, Moskotin MV, Fedorov GF, Goltsman GN. Carbon nanotube based terahertz radiation detectors. In: J. Phys.: Conf. Ser. Vol 1410.; 2019. 012208 (1 to 5).
Abstract: In this paper, we study terahertz detectors based on single quasimetallic carbon nanotubes (CNT) with asymmetric contacts and different metal pairs. We demonstrate that, depending on the contact metallization of the device, various detection mechanisms are manifested.
|
|
|
Manova NN, Smirnov EO, Korneeva YP, Korneev AA, Goltsman GN. Superconducting photon counter for nanophotonics applications. In: J. Phys.: Conf. Ser. Vol 1410.; 2019. 012147 (1 to 5).
Abstract: We develop large area superconducting single-photon detector SSPD with a micron-wide strip suitable for free-space coupling or packaging with multi-mode optical fibres. The detector sensitive area is 20 μm in diameter. In near infrared (1330 nm wavelength) our SSPD exhibits above 30% detection efficiency with low dark counts and 45 ps timing jitter.
|
|
|
Baksheeva K, Vdovydchenko A, Gorshkov K, Ozhegov R, Kinev N, Koshelets V, et al. Study of human skin radiation in the terahertz frequency range. In: J. Phys.: Conf. Ser. Vol 1410.; 2019. 012076 (1 to 5).
Abstract: The radiation of human skin in the terahertz frequency range under the influence of mental stresses has been studied in the current work. An experimental setup for observation of changes in human skin radiation, which occur under the influence of psychological stresses, by means of a superconducting integrated receiver has been developed. More than 30 volunteers participate in these studies, which allows us to verify presence of correlation between the signals from the superconducting integrated terahertz receiver and other sensors that monitor human mental stress.
|
|
|
Polyakova MI, Florya IN, Semenov AV, Korneev AA, Goltsman GN. Extracting hot-spot correlation length from SNSPD tomography data. In: J. Phys.: Conf. Ser. Vol 1410.; 2019. 012166 (1 to 4).
Abstract: We present data of quantum detector tomography for the samples specifically optimized for this problem. Using this method, we take results of hot-spot correlation length of 17 ± 2 nm.
|
|
|
Matyushkin YE, Gayduchenko IA, Moskotin MV, Goltsman GN, Fedorov GE, Rybin MG, et al. Graphene-layer and graphene-nanoribbon FETs as THz detectors. In: J. Phys.: Conf. Ser. Vol 1124.; 2018. 051054.
Abstract: We report on detection of sub-THz radiation (129-430 GHz) using graphene based asymmetric field-effect transistor (FET) structures with different channel geometry: monolayer graphene, graphene nanoribbons. In all devices types we observed the similar trends of response on sub-THz radiation. The response fell with increasing frequency at room temperature, but increased with increasing frequency at 77 K. Our calculations show that the change in the trend of the frequency dependence at 77 K is associated with the appearance of plasma waves in the graphene channel. Unusual properties of p-n junctions in graphene are highlighted using devices of special geometry.
|
|