|
Samsonova A, Zolotov P, Baeva E, Lomakin A, Titova N, Kardakova A, et al. Signatures of surface magnetic disorder in thin niobium films. IEEE Trans. Appl. Supercond.. 2021:1.
Abstract: We present our studies on the evolution of the normal and superconducting properties with thickness of thin Nb films with a low level of non-magnetic disorder (kFl 150 for the thickest film in the set). The analysis of the superconducting behavior points to the presence of magnetic moments, hidden in the native oxide on the surface of Nb films. Using the Abrikosov-Gorkov theory, we obtain the density of surface magnetic moments of 1013 cm-2, which is in agreement with the previously reported data for Nb films.
|
|
|
Shcherbatenko M, Lobanov Y, Finkel M, Maslennikov S, Pentin I, Semenov A, et al. Development of a 30 THz heterodyne receiver based on a hot-electron-bolometer mixer [abstract]. In: Proc. 25th Int. Symp. Space Terahertz Technol.; 2014. 122.
Abstract: We present new Hot-Electron-Bolometer (HEB) mixers designed for mid-IR spectroscopy targeting astrophysical and geophysical observations where high sensitivity and spectral resolution are required. The mixers are made of an ultrathin NbN film deposited on GaAs substrates. Two entirely different types of the devices have been fabricated. The first type is based on a direct radiation coupling concept and the mixing devices are shaped as squares of 5×5 μm 2 (which corresponds to the diffraction limit at the chosen wavelength) and 10×10 μm 2 (which was used to establish a possible influence of the contact pads on the radiation absorption). The second type utilizes a spiral antenna designed with HFSS. The fabrication and layout of the devices as well as the performance comparison will be presented. During the experiments, the HEB mixer was installed on the cold plate of a LHe cryostat. A germanium window and an extended semi-spherical germanium lens are used to couple the radiation. The cryostat is equipped with a germanium optical filter of thickness 0.5 mm and with a center wavelength of 10.6 mμ. The incident power absorption is measured by using the isothermal method. As a Local Oscillator, a 10.6 micrometers line of a CO2 gas laser is used. We further characterize the frequency response of the spiral antenna with a FIR-spectrometer. The noise characteristics of the mixers are determined from a room temperature cold load and a heated black body at ~600 K as a hot load.
|
|
|
Bell M, Sergeev A, Goltsman G, Bird J, Verevkin A. Transition-edge sensors based on superconducting nanowires [abstract]. In: Proc. APS March Meeting.; 2006. B38.00001.
Abstract: We present our experimental study of superconducting NbN nanowire-based sensor. The responsivity of the sensor is strongly affected by the superconducting transition width of the nanostructure, which, in turn, is determined by the phase slip centers (PCSs) dynamics. The fluctuations and noise properties of the sensor are also discussed, as well as the devices' behavior at high magnetic fields. The ultimate performance of the sensor and prospects of the devices will be discussed, as well.
|
|
|
Gershenzon EM, Gol'tsman GN, Ptitsyna NG. Carrier lifetime in excited states of shallow impurities in germanium. JETP Lett. 1977;25(12):539–43.
|
|
|
Gershenzon EM, Gol'tsman GN. Transitions of electrons between excited states of donors in germanium. JETP Lett. 1971;14(2):63–5.
|
|
|
Gershenzon EM, Orlov LA, Ptitsina NG. Absorption spectra in electron transitions between excited states of impurities in germanium. JETP Lett. 1975;22(4):95–7.
|
|
|
Gorokhov G, Bychanok D, Gayduchenko I, Rogov Y, Zhukova E, Zhukov S, et al. THz spectroscopy as a versatile tool for filler distribution diagnostics in polymer nanocomposites. Polymers (Basel). 2020;12(12):3037 (1 to 14).
Abstract: Polymer composites containing nanocarbon fillers are under intensive investigation worldwide due to their remarkable electromagnetic properties distinguished not only by components as such, but the distribution and interaction of the fillers inside the polymer matrix. The theory herein reveals that a particular effect connected with the homogeneity of a composite manifests itself in the terahertz range. Transmission time-domain terahertz spectroscopy was applied to the investigation of nanocomposites obtained by co-extrusion of PLA polymer with additions of graphene nanoplatelets and multi-walled carbon nanotubes. The THz peak of permittivity's imaginary part predicted by the applied model was experimentally shown for GNP-containing composites both below and above the percolation threshold. The physical nature of the peak was explained by the impact on filler particles excluded from the percolation network due to the peculiarities of filler distribution. Terahertz spectroscopy as a versatile instrument of filler distribution diagnostics is discussed.
|
|
|
Gershenzon EM, Goltsman GN, Ptitsyna NG. Investigation of excited donor states in GaAs. Sov Phys Semicond. 1974;7(10):1248–50.
|
|
|
Steudle GA, Schietinger S, Höckel D, Dorenbos SN, Zadeh IE, Zwiller V, et al. Measuring the quantum nature of light with a single source and a single detector. Phys. Rev. A. 2012;86(5):053814.
Abstract: An elementary experiment in optics consists of a light source and a detector. Yet, if the source generates nonclassical correlations such an experiment is capable of unambiguously demonstrating the quantum nature of light. We realized such an experiment with a defect center in diamond and a superconducting detector. Previous experiments relied on more complex setups, such as the Hanbury Brown and Twiss configuration, where a beam splitter directs light to two photodetectors, creating the false impression that the beam splitter is a fundamentally required element. As an additional benefit, our results provide a simplification of the widely used photon-correlation techniques.
|
|
|
Stellari F, Song P. Testing of ultra low voltage CMOS microprocessors using the superconducting single-photon detector (SSPD). In: Proc. 12th IPFA. IEEE; 2005. 2.
Abstract: In F. Stellari and P. Song (2004) the authors have shown a comparison among different detectors used for diagnosing integrated circuits (ICs) by means of the PICA method. In their experiments they used two versions of the SSPD detector (p-SSPD is a prototype version, while c-SSPD is the first commercially available generation of the detector as presented in W. K. Lo et al. (2002), as well as the imaging detector (S-25 photo-multiplier tube (PMT) as discussed in W. G. McMullan (1987)) used in the conventional PICA technique. A microprocessor chip fabricated in a 0.13 μm 1.2 V technology is used to show that c-SSPD provides a significant reduction in acquisition time for the collection of optical waveforms from chips running at very low. In this paper, the authors summarize the main results.
|
|