|
Gershenzon EM, Gol'tsman GN, Potapov VD, Sergeev AV. Restriction of microwave enhancement of superconductivity in impure superconductors due to electron-electron interaction. Solid State Communications. 1990;75(8):639–41.
Abstract: Transition from microwave enhancement of supercurrent to superconductivity suppression is investigated in impure superconductors. It is demonstrated that the frequency range of the enhancement effect narrows with the decrease of the electron mean free path, l, and at l ⩽ 1 nm electron heating is observed in the whole frequency range. Dependences of frequency boundaries on l are explained by taking into account strong electron-electron interaction in impure metals.
|
|
|
Gershenzon EM, Gol'tsman GN, Emtsev VV, Mashovets TV, Ptitsyna NG, Ryvkin SM. Role of impurities of groups III and V in the formation of defects following γ irradiation of germanium. JETP Lett. 1971;14(6):241.
|
|
|
Gershenzon EM, Gol'tsman GN, Dzardanov AL, Elant'ev AI, Zorin MA, Markin AG, et al. S-N switching of niobium and YBCO films: limit time and perspective of fast key element creation. Sverkhprovodimost': Fizika, Khimiya, Tekhnika. 1992;5(12):2386–402.
Abstract: A study was made on processes of switching of thin niobium film strips between superconducting and normal states under the effect of optical radiation pulse and voltage step. The results are described satisfactorily by the model of spatial homogeneous electron heating. It is shown that limiting switching times can be equal to several shares of nanosecond at 4.2 K. Preliminary results for YBa2Cu3O-7-x films are presented. Prospects and advantages of creation of ducting structures of narrow streps, are discussed.
|
|
|
Gol'tsman GN, Semenov AD, Gousev YP, Zorin MA, Gogidze IG, Gershenzon EM, et al. Sensitive picosecond NbN detector for radiation from millimetre wavelengths to visible light. Supercond Sci Technol. 1991;4(9):453–6.
Abstract: The authors report on the application of a broad-band NbN film detector which has high sensitivity and picosecond response time for detection of radiation from millimetre wavelengths to visible light. From a study of amplitude modulated radiation of backward-wave tubes and picosecond pulses from gas and solid state lasers at wavelengths between 2 mm and 0.53 mu m, they found a detectivity of 1010 W-1 cm Hz-1/2 and a response time of less than 50 ps at T=10 K. The characteristics were provided by using a 150 AA thick NbN film patterned into a structure of micron strips. According to the proposed detection mechanism, namely electron heating, they expect an intrinsic response time of approximately 20 ps at the same temperature.
|
|
|
Korneev A, Kouminov P, Matvienko V, Chulkova G, Smirnov K, Voronov B, et al. Sensitivity and gigahertz counting performance of NbN superconducting single-photon detectors. Appl Phys Lett. 2004;84(26):5338–40.
Abstract: We have measured the quantum efficiencysQEd, GHz counting rate, jitter, and noise-equivalentpowersNEPdof nanostructured NbN superconducting single-photon detectorssSSPDsdin thevisible to infrared radiation range. Our 3.5-nm-thick and 100- to 200-nm-wide meander-typedevices(total area 10310mm2), operating at 4.2 K, exhibit an experimental QE of up to 20% inthe visible range and,10% at 1.3 to 1.55mm wavelength and are potentially sensitive up tomidinfrareds,10mmdradiation. The SSPD counting rate was measured to be above 2 GHz withjitter,18 ps, independent of the wavelength. The devices’ NEP varies from,10−17W/Hz1/2for1.55mm photons to,10−20W/Hz1/2for visible radiation. Lowering the SSPD operatingtemperature to 2.3 K significantly enhanced its performance, by increasing the QE to,20% andlowering the NEP level to,3310−22W/Hz1/2, both measured at 1.26mm wavelength.
|
|
|
Sclafani M, Marksteiner M, Keir FML, Divochiy A, Korneev A, Semenov A, et al. Sensitivity of a superconducting nanowire detector for single ions at low energy. Nanotechnol. 2012;23(6):065501 (1 to 5).
Abstract: We report on the characterization of a superconducting nanowire detector for ions at low kinetic energies. We measure the absolute single-particle detection efficiency eta and trace its increase with energy up to eta = 100%. We discuss the influence of noble gas adsorbates on the cryogenic surface and analyze their relevance for the detection of slow massive particles. We apply a recent model for the hot-spot formation to the incidence of atomic ions at energies between 0.2 and 1 keV. We suggest how the differences observed for photons and atoms or molecules can be related to the surface condition of the detector and we propose that the restoration of proper surface conditions may open a new avenue for SSPD-based optical spectroscopy on molecules and nanoparticles.
|
|
|
Morozov P, Lukina M, Shirmanova M, Divochiy A, Dudenkova V, Gol'tsman GN, et al. Singlet oxygen phosphorescence imaging by superconducting single-photon detector and time-correlated single-photon counting. Opt Lett. 2021;46(6):1217–20.
Abstract: This Letter presents, to the best of our knowledge, a novel optical configuration for direct time-resolved measurements of luminescence from singlet oxygen, both in solutions and from cultured cells on photodynamic therapy. The system is based on the superconducting single-photon detector, coupled to the confocal scanner that is modified for the near-infrared measurements. The recording of a phosphorescence signal from singlet oxygen at 1270 nm has been done using time-correlated single-photon counting. The performance of the system is verified by measuring phosphorescence from singlet oxygen generated by the photosensitizers commonly used in photodynamic therapy: methylene blue and chlorin e6. The described system can be easily upgraded to the configuration when both phosphorescence from singlet oxygen and fluorescence from the cells can be detected in the imaging mode. Thus, co-localization of the signal from singlet oxygen with the areas inside the cells can be done.
|
|
|
Gol'tsman G, Jacobsson S, Ekstrom H, Karasik B, Kollberg E, Gershenzon E. Slot-line tapered antenna with NbN hot electron mixer for 300-360 GHz operation. In: Proc. 5th Int. Symp. Space Terahertz Technol.; 1994. p. 209–213a.
Abstract: NbN hot-electron mixers combined with slot-line tapered antennas on Si wdnitride membranes had been fabricated. Several strips of 1 gm wide and 5 tan long made from 100 A NbN film are inserted into the slot antenna. IV-curves under local oscillator power in 300-350 GHz frequency range and conversion gain dependencies on intermediate fre- quency in the 0.1-1 GHz range are measured and compared with that for 100 GHz frequency band. Our results show that pumped IV-curves and intermediate frequency bands are different for 100 GHz and 300 GHz frequency ranges. The interpretation exploits the fact that for the lowest radiation frequency the superconducting energy gap is larger than the radiation quantum energy while they are comparable at the higher frequency. Tha results show that such mixers have good perspectives for terahertz receiving technology.
|
|
|
Verevkin A, Zhang J, Slysz W, Sobolewski R, Lipatov A, Okunev O, et al. Spectral sensitivity and temporal resolution of NbN superconducting single-photon detectors. In: Proc. 13th Int. Symp. Space Terahertz Technol.; 2002. p. 105–11.
Abstract: We report our studies on spectral sensitivity and time resolution of superconducting NbN thin film single-photon detectors (SPDs). Our SPDs exhibit an everimentally measured detection efficiencies (DE) from — 0.2% at 2=1550 nm up to —3% at lambda=405 nm wavelength for 10-nm film thickness devices and up to 3.5% at lambda=1550 nm for 3.5-nm film thickness devices. Spectral dependences of detection efficiency (DE) at 2=0.4 —3.0 pm range are presented. With variable optical delay setup, it is shown that NbN SPD potentially can resolve optical pulses with the repetition rate up to 10 GHz at least. The observed full width at the half maximum (FWHM) of the signal pulse is about 150-180 ps, limited by read-out electronics. The jitter of NbN SPD is measured to be —35 ps at optimum biasing.
|
|
|
Reiger E, Pan D, Slysz W, Jukna A, Sobolewski R, Dorenbos S, et al. Spectroscopy with nanostructured superconducting single photon detectors. IEEE J Select Topics Quantum Electron. 2007;13(4):934–43.
Abstract: Superconducting single-photon detectors (SSPDs) are nanostructured devices made from ultrathin superconducting films. They are typically operated at liquid helium temperature and exhibit high detection efficiency, in combination with very low dark counts, fast response time, and extremely low timing jitter, within a broad wavelength range from ultraviolet to mid-infrared (up to 6 mu m). SSPDs are very attractive for applications such as fiber-based telecommunication, where single-photon sensitivity and high photon-counting rates are required. We review the current state-of-the-art in the SSPD research and development, and compare the SSPD performance to the best semiconducting avalanche photodiodes and other superconducting photon detectors. Furthermore, we demonstrate that SSPDs can also be successfully implemented in photon-energy-resolving experiments. Our approach is based on the fact that the size of the hotspot, a nonsuperconducting region generated upon photon absorption, is linearly dependent on the photon energy. We introduce a statistical method, where, by measuring the SSPD system detection efficiency at different bias currents, we are able to resolve the wavelength of the incident photons with a resolution of 50 nm.
|
|