Vachtomin YB, Antipov SV, Maslennikov SN, Smirnov KV, Polyakov SL, Kaurova NS, et al. Noise temperature measurements of NbN phonon-cooled hot electron bolometer mixer at 2.5 and 3.8 THz. In: Proc. 15th Int. Symp. Space Terahertz Technol. Northampton, Massachusetts, USA; 2004. p. 236–41.
Abstract: We present the results of noise temperature measurements of NbN phonon-cooled HEB mixers based on a 3.5 nm NbN film deposited on a high-resistivity Si substrate with a 200 nm – thick MgO buffer layer. The mixer element was integrated with a log-periodic spiral antenna. The noise temperature measurements were performed at 2.5 THz and at 3.8 THz local oscillator frequencies for the 3 µm x 0.2 µm active area devices. The best uncorrected receiver noise temperatures found for these frequencies are 1300 K and 3100 K, respectively. A water vapour discharge laser was used as the LO source. We also present the results of direct detection contribution to the measured Y-factor and of a possible error of noise temperature calculation. This error was more than 8% for the mixer with in-plane dimensions of 2.4 x 0.16 µm 2 at the optimal noise temperature point. The use of a mesh filter enabled us to avoid the effect of direct detection and decrease optical losses by 0.5 dB. The paper is concluded by the investigation results of the mixer polarization response. It was shown that the polarization can differ from the circular one at 3.8 THz by more than 2 dB.
|
|
|
Ozhegov R, Morozov D, Maslennikov S, Okunev O, Smirnov K, Gol'tsman G. Submillimeter wave range imaging system for registering human body radiation and finding out the things covered under clothes. In: Proc. 3rd Int. exhibition and conf. Non-Destructive Testing Equipment and Devices. Moscow; 2004.
|
|
|
Ozhegov R, Maslennikov S, Morozov D, Okunev O, Smirnov K, Gol'tsman G. Imaging system for submillimeter wave range. In: Proc. Tenth All-Russian sceintific conference of student-physicists and young sceintists (VNKSF-10). Moscow; 2004.
|
|
|
Maslennikov S, Vachtomin Y, Antipov S, Smirnov K, Kaurova N, Grishina E, et al. NbN HEB mixers for frequencies of 2.5 and 3.8 THz. In: Proc. Tenth All-Russian sceintific conference of student-physicists and young sceintists (VNKSF-10). Moscow; 2004.
|
|
|
Antipov SV, Vachtomin YB, Maslennikov SN, Smirnov KV, Kaurova NS, Grishina EV, et al. Noise performance of quasioptical ultrathin NbN hot electron bolometer mixer at 2.5 and 3.8 THz. In: Proc. 5-th MSMW. Vol 2. Kharkov, Ukraine; 2004. p. 592–4.
Abstract: To put space-based and airborne heterodyne instruments into operation at frequencies above 1 THz the superconducting NbN hot-electron bolometer (HEB) will be incorporated into heterodyne receiver as a mixer. At frequencies above 1.3 THz the sensitivity of the NbN HEB mixers outperform the one of the Schottky diodes and SIS-mixers, and the receiver noise temperature of the NbN HEB mixers increase with frequency. In this paper we present the results of the noise temperature measurements within one batch of NbN HEB mixers based on 3.5 mn thick superconducting NbN film grown on Si substrate with MgO buffer layer at the LO frequencies 2.5 THz and 3.8 THz.
|
|
|
Vachtomin YB, Antipov SV, Kaurova NS, Maslennikov SN, Smirnov KV, Polyakov SL, et al. Noise temperature, gain bandwidth and local oscillator power of NbN phonon-cooled HEB mixer at terahertz frequenciess. In: Proc. 29th IRMMW / 12th THz. Karlsruhe, Germany; 2004. p. 329–30.
Abstract: We present the performances of HEB mixers based on 3.5 nm thick NbN film integrated with log-periodic spiral antenna. The double side-band receiver noise temperature values are 1300 K and 3100 K at 2.5 THz and at 3.8 THz, respectively. The gain bandwidth of the mixer is 4.2 GHz and the noise bandwidth is 5 GHz. The local oscillator power is 1-3 /spl mu/W for mixers with different active area.
|
|
|
Kaurova NS, Finkel MI, Maslennikov SN, Vahtomin YB, Antipov SV, Smirnov KV, et al. Submillimeter mixer based on YBa2Cu3O7-x thin film. In: Proc. 1-st conf. Fundamental problems of high temperature superconductivity. Moscow-Zvenigorod; 2004. 291.
|
|
|
Ozhegov RV, Gorshkov KN, Smirnov KV, Gol’tsman GN, Filippenko LV, Koshelets VP. Terahertz imaging system based on superconducting integrated receiver. In: Proc. 2-nd Int. Conf. Terahertz and Microwave radiation: Generation, Detection and Applications.; 2010. p. 20–2.
Abstract: The development of terahertz imaging instruments for security systems is on the cutting edge of terahertz technology. We are developing a THz imaging system based on a superconducting integrated receiver (SIR). An SIR is a new type of heterodyne receiver based on an SIS mixer integrated with a flux-flow oscillator (FFO) and a harmonic mixer which is used for phase-locking the FFO. Developing an array of SIRs would allow obtaining amplitude and phase characteristics of incident radiation in the plane of the receiver. Employing an SIR in an imaging system means building an entirely new instrument with many advantages compare to traditional systems: i) high temperature resolution, comparable to the best results for incoherent receivers; ii) high spectral resolution allowing spectral analysis of various substances; iii) the local oscillator frequency can be varied to obtain images at different frequencies, effectively providing “color” images; iv) since a heterodyne receiver preserves the phase of the radiation, it is possible to construct 3D images. The paper presents a prototype THz imaging system using an 1 pixel SIR. We have studied the dependence of the noise equivalent temperature difference (NETD) on the integration time and also possible ways of achieving best possible sensitivity. An NETD of 13 mK was obtained with an integration time of 1 sec a detection bandwidth of 4 GHz at a local oscillator frequency of 520 GHz. An important advantage of an FFO is its wide operation range: 300-700 GHz.
|
|
|
Verevkin A, Slysz W, Pearlman A, Zhang J, Sobolewski R, Okunev O, et al. Real-time GHz-rate counting of infrared photons using nanostructured NbN superconducting detectors. In: CLEO/QELS. Optical Society of America; 2003. CThM8.
Abstract: We demonstrate that our ultrathin, nanometer-width NbN superconducting single-photon detectors are capable of above 1-GHz-frequency, real-time counting of near-infrared photons. The measured system jitter of the detector is below 15 ps.
|
|
|
Ozhegov RV, Gorshkov KN, Vachtomin YB, Smirnov KV, Finkel MI, Goltsman GN, et al. Terahertz imaging system based on superconducting heterodyne integrated receiver. In: Corsi C, Sizov F, editors. Proc. THz and Security Applications. Dordrecht: Springer Netherlands; 2014. p. 113–25.
Abstract: The development of terahertz imaging instruments for security systems is on the cutting edge of terahertz technology. We are developing a THz imaging system based on a superconducting integrated receiver (SIR). An SIR is a new type of heterodyne receiver based on an SIS mixer integrated with a flux-flow oscillator (FFO) and a harmonic mixer which is used for phase-locking the FFO. Employing an SIR in an imaging system means building an entirely new instrument with many advantages compared to traditional systems.
In this project we propose a prototype THz imaging system using an 1 pixel SIR and 2D scanner. At a local oscillator frequency of 500 GHz the best noise equivalent temperature difference (NETD) of the SIR is 10 mK at an integration time of 1 s and a detection bandwidth of 4 GHz. The scanner consists of two rotating flat mirrors placed in front of the antenna consisting of a spherical primary reflector and an aspherical secondary reflector. The diameter of the primary reflector is 0.3 m. The operating frequency of the imaging system is 600 GHz, the frame rate is 0.1 FPS, the scanning area is 0.5 × 0.5 m2, the image resolution is 50 × 50 pixels, the distance from an object to the scanner was 3 m. We have obtained THz images with a spatial resolution of 8 mm and a NETD of less than 2 K.
|
|