Cherednichenko S, Kroug M, Khosropanah P, Adam A, Merkel H, Kolberg E, et al. A broadband terahertz heterodyne receiver with an NbN HEB mixer. In: Harward University, editor. Proc. 13th Int. Symp. Space Terahertz Technol. Cambridge, MA, USA; 2002. p. 85–95.
Abstract: We present a broadband and low noise heterodyne receiver for 1.4-1.7 THz designed for the Hershel Space Observatory. A phonon- cooled NbN HEB mixer was integrated with a normal metal double- slot antenna and an elliptical silicon lens. DSB receiver noise temperature Tr was measured from 1 GHz through 8GHz intermediate frequency band with 50 MHz instantaneous bandwidth. At 4.2 K bath temperature and at 1.6 THz LO frequency Tr is 800 K with the receiver noise bandwidth of 5 GHz. While at 2 K bath temperature Tr was as low as 700 K. At 0.6 THz and 1.1 THz a spiral antenna integrated NbN HEB mixer showed the receiver noise temperature 500 K and 800 K, though no antireflection coating was used in this case. Tr of 1100 K was achieved at 2.5 THz while the receiver noise bandwidth was 4 GHz.
|
|
|
Hajenius M, Baselmans JJA, Gao JR, Klapwijk TM, de Korte PAJ, Voronov B, et al. Improved NbN phonon cooled hot electron bolometer mixers. In: Proc. 14th Int. Symp. Space Terahertz Technol. Tucson, USA; 2003. p. 413–23.
Abstract: NbN phonon-cooled hot electron bolometer mixers (HEBs) have been realized with negligible contact resistance to Au pads. By adding either a 5 nm Nb or a 10 nm NbTiN layer between the Au and NbN, to preserve superconductivity in the NbN under the Au contact pad, superior noise temperatures have been obtained. Using DC I,V curves and resistive transitions in combination with process parameters we analyze the nature of these improved devices and determine interface transparencies.
|
|
|
Vachtomin YB, Antipov SV, Maslennikov SN, Smirnov KV, Polyakov SL, Kaurova NS, et al. Noise temperature measurements of NbN phonon-cooled hot electron bolometer mixer at 2.5 and 3.8 THz. In: Proc. 15th Int. Symp. Space Terahertz Technol. Northampton, Massachusetts, USA; 2004. p. 236–41.
Abstract: We present the results of noise temperature measurements of NbN phonon-cooled HEB mixers based on a 3.5 nm NbN film deposited on a high-resistivity Si substrate with a 200 nm – thick MgO buffer layer. The mixer element was integrated with a log-periodic spiral antenna. The noise temperature measurements were performed at 2.5 THz and at 3.8 THz local oscillator frequencies for the 3 µm x 0.2 µm active area devices. The best uncorrected receiver noise temperatures found for these frequencies are 1300 K and 3100 K, respectively. A water vapour discharge laser was used as the LO source. We also present the results of direct detection contribution to the measured Y-factor and of a possible error of noise temperature calculation. This error was more than 8% for the mixer with in-plane dimensions of 2.4 x 0.16 µm 2 at the optimal noise temperature point. The use of a mesh filter enabled us to avoid the effect of direct detection and decrease optical losses by 0.5 dB. The paper is concluded by the investigation results of the mixer polarization response. It was shown that the polarization can differ from the circular one at 3.8 THz by more than 2 dB.
|
|
|
Ozhegov R, Morozov D, Maslennikov S, Okunev O, Smirnov K, Gol'tsman G. Submillimeter wave range imaging system for registering human body radiation and finding out the things covered under clothes. In: Proc. 3rd Int. exhibition and conf. Non-Destructive Testing Equipment and Devices. Moscow; 2004.
|
|
|
Ожегов РВ, Морозов ДВ, Масленников СН, Смирнов КВ, Окунев ОВ, Гольцман ГН. Тепловизор субмиллиметрового диапазона волн для регистрации теплового излучения тела человека и обнаружения скрытых под одеждой предметов. In: 3-я Международная выставка и конференция Неразрушающий контроль и техническая диагностика в промышленности. Москва; 2004.
|
|
|
Ozhegov R, Maslennikov S, Morozov D, Okunev O, Smirnov K, Gol'tsman G. Imaging system for submillimeter wave range. In: Proc. Tenth All-Russian sceintific conference of student-physicists and young sceintists (VNKSF-10). Moscow; 2004.
|
|
|
Ожегов РВ, Масленников СН, Морозов ДВ, Окунев ОВ, Смирнов КВ, Гольцман ГН. Тепловизор субмиллиметрового диапазона длин волн. In: Десятая всероссийская научная конференция студентов-физиков и молодых ученых (ВНКСФ-10). Москва; 2004.
|
|
|
Maslennikov S, Vachtomin Y, Antipov S, Smirnov K, Kaurova N, Grishina E, et al. NbN HEB mixers for frequencies of 2.5 and 3.8 THz. In: Proc. Tenth All-Russian sceintific conference of student-physicists and young sceintists (VNKSF-10). Moscow; 2004.
|
|
|
Масленников СН, Вахтомин ЮБ, Антипов СВ, Смирнов КВ, Каурова НС, Гришина ЕВ, et al. Смесители на основе электронного разогрева в тонких пленках NbN для частот 2.5 и 3.8 ТГц. In: Десятая всероссийская научная конференция студентов-физиков и молодых ученых (ВНКСФ-10). Москва; 2004.
|
|
|
Vachtomin YB, Antipov SV, Kaurova NS, Maslennikov SN, Smirnov KV, Polyakov SL, et al. Noise temperature, gain bandwidth and local oscillator power of NbN phonon-cooled HEB mixer at terahertz frequenciess. In: Proc. 29th IRMMW / 12th THz. Karlsruhe, Germany; 2004. p. 329–30.
Abstract: We present the performances of HEB mixers based on 3.5 nm thick NbN film integrated with log-periodic spiral antenna. The double side-band receiver noise temperature values are 1300 K and 3100 K at 2.5 THz and at 3.8 THz, respectively. The gain bandwidth of the mixer is 4.2 GHz and the noise bandwidth is 5 GHz. The local oscillator power is 1-3 /spl mu/W for mixers with different active area.
|
|