|
Records |
Links |
|
Author |
Mohan, N.; Minaeva, O.; Gol'tsman, G. N.; Nasr, M. B.; Saleh, B. E.; Sergienko, A. V.; Teich, M. C. |
|
|
Title |
Photon-counting optical coherence-domain reflectometry using superconducting single-photon detectors |
Type |
Journal Article |
|
Year |
2008 |
Publication |
Opt. Express |
Abbreviated Journal |
Opt. Express |
|
|
Volume |
16 |
Issue |
22 |
Pages |
18118-18130 |
|
|
Keywords |
SSPD, SNSPD |
|
|
Abstract |
We consider the use of single-photon counting detectors in coherence-domain imaging. Detectors operated in this mode exhibit reduced noise, which leads to increased sensitivity for weak light sources and weakly reflecting samples. In particular, we experimentally demonstrate the possibility of using superconducting single-photon detectors (SSPDs) for optical coherence-domain reflectometry (OCDR). These detectors are sensitive over the full spectral range that is useful for carrying out such imaging in biological samples. With counting rates as high as 100 MHz, SSPDs also offer a high rate of data acquisition if the light flux is sufficient. |
|
|
Address |
Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA. nm82@bu.edu |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1094-4087 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
PMID:18958090 |
Approved |
no |
|
|
Call Number |
|
Serial |
1407 |
|
Permanent link to this record |
|
|
|
|
Author |
Nasr, M. B.; Minaeva, O.; Goltsman, G. N.; Sergienko, A. V.; Saleh, B. E.; Teich, M. C. |
|
|
Title |
Submicron axial resolution in an ultrabroadband two-photon interferometer using superconducting single-photon detectors |
Type |
Journal Article |
|
Year |
2008 |
Publication |
Opt. Express |
Abbreviated Journal |
Opt. Express |
|
|
Volume |
16 |
Issue |
19 |
Pages |
15104-15108 |
|
|
Keywords |
SSPD, SNSPD |
|
|
Abstract |
We generate ultrabroadband biphotons via the process of spontaneous parametric down-conversion in a quasi-phase-matched nonlinear grating that has a linearly chirped poling period. Using these biphotons in conjunction with superconducting single-photon detectors (SSPDs), we measure the narrowest Hong-Ou-Mandel dip to date in a two-photon interferometer, having a full width at half maximum (FWHM) of approximately 5.7 fsec. This FWHM corresponds to a quantum optical coherence tomography (QOCT) axial resolution of 0.85 µm. Our results indicate that a high flux of nonoverlapping biphotons may be generated, as required in many applications of nonclassical light. |
|
|
Address |
Departments of Electrical & Computer Engineering and Physics, Quantum Imaging Laboratory, Boston University, Boston, MA 02215, USA. boshra@bu.edu |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1094-4087 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
PMID:18795048 |
Approved |
no |
|
|
Call Number |
|
Serial |
1408 |
|
Permanent link to this record |
|
|
|
|
Author |
Morozov, P.; Lukina, M.; Shirmanova, M.; Divochiy, A.; Dudenkova, V.; Gol'tsman, G. N.; Becker, W.; Shcheslavskiy, V. I. |
|
|
Title |
Singlet oxygen phosphorescence imaging by superconducting single-photon detector and time-correlated single-photon counting |
Type |
Journal Article |
|
Year |
2021 |
Publication |
Opt. Lett. |
Abbreviated Journal |
Opt. Lett. |
|
|
Volume |
46 |
Issue |
6 |
Pages |
1217-1220 |
|
|
Keywords |
SSPD, SNSPD, applications |
|
|
Abstract |
This Letter presents, to the best of our knowledge, a novel optical configuration for direct time-resolved measurements of luminescence from singlet oxygen, both in solutions and from cultured cells on photodynamic therapy. The system is based on the superconducting single-photon detector, coupled to the confocal scanner that is modified for the near-infrared measurements. The recording of a phosphorescence signal from singlet oxygen at 1270 nm has been done using time-correlated single-photon counting. The performance of the system is verified by measuring phosphorescence from singlet oxygen generated by the photosensitizers commonly used in photodynamic therapy: methylene blue and chlorin e6. The described system can be easily upgraded to the configuration when both phosphorescence from singlet oxygen and fluorescence from the cells can be detected in the imaging mode. Thus, co-localization of the signal from singlet oxygen with the areas inside the cells can be done. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0146-9592 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
PMID:33720151 |
Approved |
no |
|
|
Call Number |
|
Serial |
1221 |
|
Permanent link to this record |
|
|
|
|
Author |
Vorobyov, V. V.; Kazakov, A. Y.; Soshenko, V. V.; Korneev, A. A.; Shalaginov, M. Y.; Bolshedvorskii, S. V.; Sorokin, V. N.; Divochiy, A. V.; Vakhtomin, Y. B.; Smirnov, K. V.; Voronov, B. M.; Shalaev, V. M.; Akimov, A. V.; Goltsman, G. N. |
|
|
Title |
Superconducting detector for visible and near-infrared quantum emitters [Invited] |
Type |
Journal Article |
|
Year |
2017 |
Publication |
Opt. Mater. Express |
Abbreviated Journal |
Opt. Mater. Express |
|
|
Volume |
7 |
Issue |
2 |
Pages |
513-526 |
|
|
Keywords |
SSPD, SNSPD |
|
|
Abstract |
Further development of quantum emitter based communication and sensing applications intrinsically depends on the availability of robust single-photon detectors. Here, we demonstrate a new generation of superconducting single-photon detectors specifically optimized for the 500–1100 nm wavelength range, which overlaps with the emission spectrum of many interesting solid-state atom-like systems, such as nitrogen-vacancy and silicon-vacancy centers in diamond. The fabricated detectors have a wide dynamic range (up to 350 million counts per second), low dark count rate (down to 0.1 counts per second), excellent jitter (62 ps), and the possibility of on-chip integration with a quantum emitter. In addition to performance characterization, we tested the detectors in real experimental conditions involving nanodiamond nitrogen-vacancy emitters enhanced by a hyperbolic metamaterial. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
2159-3930 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1234 |
|
Permanent link to this record |
|
|
|
|
Author |
Seki, T.; Shibata, H.; Takesue, H.; Tokura, Y.; Imoto, N. |
|
|
Title |
Comparison of timing jitter between NbN superconducting single-photon detector and avalanche photodiode |
Type |
Journal Article |
|
Year |
2010 |
Publication |
Phys. C |
Abbreviated Journal |
Phys. C |
|
|
Volume |
470 |
Issue |
20 |
Pages |
1534-1537 |
|
|
Keywords |
SSPD; APD; jitter |
|
|
Abstract |
We report the pulse-to-pulse timing jitter measurement of a niobium nitride (NbN) superconducting single-photon detector (SSPD) and an InGaAs avalanche photodiode (APD) at 1550-nm wavelength. A direct comparison of their timing jitter was performed by using the same experimental configuration to measure both detectors. The measured jitter of the SSPD and the APD are 75 and 84 ps at full-width at half-maximum (FWHM), and 138 and 384 ps at full-width at tenth-maximum (FWTM), respectively. The jitter of the SSPD remains small at FWTM while that of APD is wide. We also estimated the transmission distances and secure key generation rates for fiber-based quantum key distribution (QKD) which uses these detectors. The estimated transmission distances of the APD are 86 km and 107 km with respect to 1 ns and 100 ps time windows, respectively, and those of the SSPD are 125 km and 172 km with respect to 1 ns and 100 ps time windows, respectively. This estimation indicates the SSPDЃfs advantages for QKD compared to the APD. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
RPLAB @ akorneev @ |
Serial |
613 |
|
Permanent link to this record |