|
Polyakova MI, Florya IN, Semenov AV, Korneev AA, Goltsman GN. Extracting hot-spot correlation length from SNSPD tomography data. In: J. Phys.: Conf. Ser. Vol 1410.; 2019. 012166 (1 to 4).
Abstract: We present data of quantum detector tomography for the samples specifically optimized for this problem. Using this method, we take results of hot-spot correlation length of 17 ± 2 nm.
|
|
|
Dryazgov M, Semenov A, Manova N, Korneeva Y, Korneev A. Modelling of normal domain evolution after single-photon absorption of a superconducting strip of micron width. In: J. Phys.: Conf. Ser. Vol 1695.; 2020. 012195 (1 to 4).
Abstract: The present paper describes a modelling of normal domain evolution in superconducting strip of micron width using solving differential equations describing the temperature and current changes. The solving results are compared with experimental data. This comparison demonstrates the high accuracy of the model. In future, it is possible to employ this model for improvement of single photon detector based on micron-scale superconducting strips.
|
|
|
Polyakova MI, Korneev AA, Semenov AV. Comparison single- and double- spot detection efficiencies of SSPD based to MoSi and NbN films. In: J. Phys.: Conf. Ser. Vol 1695.; 2020. 012146 (1 to 3).
Abstract: In this work, we present results of quantum detector tomography of superconducting single photon detector (SSPD) based on MoSi film, and compare them with previously reported data on NbN. We find that for both materials hot spot interaction length coincides with the strip width, and the dependence of single and double-spot detection efficiencies on bias current are compatible with sufficiently large hot-spot size, approaching the strip width.
|
|
|
Elezov MS, Semenov AV, An PP, Tarkhov MA, Goltsman GN, Kardakova AI, et al. Investigating the detection regimes of a superconducting single-photon detector. J Opt Technol. 2013;80(7):435.
Abstract: The detection regimes of a superconducting single-photon detector have been investigated. A technique is proposed for determining the regions in which “pure regimes” predominate. Based on experimental data, the dependences of the internal quantum efficiency on the bias current are determined in the one-, two-, and three-photon detection regimes.
|
|
|
Gousev YP, Gol'tsman GN, Semenov AD, Gershenzon EM, Nebosis RS, Heusinger MA, et al. Broadband ultrafast superconducting NbN detector for electromagnetic radiation. J Appl Phys. 1994;75(7):3695–7.
Abstract: An ultrafast detector that is sensitive to radiation in a broad spectral range from submillimeter waves to visible light is reported. It consists of a structured NbN thin film cooled to a temperature below Tc (∼11 K). Using 20 ps pulses of a GaAs laser, we observed signal pulses with both rise and decay time of about 50 ps. From the analysis of a mixing experiment with submillimeter radiation we estimate an intrinsic response time of the detector of ∼12 ps. The sensitivity was found to be similar for the near‐infrared and submillimeter radiation. Broadband sensitivity and short response time are attributed to a quasiparticle heating effect.
|
|