Tong C-YE, Kawamura J, Todd RH, Papa DC, Blundell R, Smith M, et al. Successful operation of a 1 THz NbN hot-electron bolometer receiver. In: Proc. 11th Int. Symp. Space Terahertz Technol.; 2000. p. 49–59.
Abstract: A phonon-cooled NbN superconductive hot-electron bolometer receiver covering the frequency range 0.8-1.04 THz has successfully been used for astronomical observation at the Sub-Millimeter Telescope Observatory on Mount Graham, Arizona. This waveguide heterodyne receiver is a modified version of our fixed-tuned 800 GHz HEB receiver to allow for operation beyond 1 THz. The measured noise temperature of this receiver is about 1250 K at 0.81 THz, 560 K at 0.84 THz, and 1600 K at 1.035 THz. It has a 1 GHz wide IF bandwidth, centered at 1.8 GHz. This receiver has recently been used to detect the CO (9-8) molecular line emission at 1.037 THz in the Orion nebula. This is the first time a ground-based heterodyne receiver has been used to detect a celestial source above 1 THz.
|
Tong C-YE, Trifonov A, Shurakov A, Blundell R, Gol’tsman G. A microwave-operated hot-electron-bolometric power detector for terahertz radiation. IEEE Trans Appl Supercond. 2015;25(3):2300604 (1 to 4).
Abstract: A new class of microwave-operated THz power detectors based on the NbN hot-electron-bolometer (HEB) mixer is proposed. The injected microwave signal ( 1 GHz) serves the dual purpose of pumping the HEB element and enabling the read-out of the internal state of the device. A cryogenic amplifier amplifies the reflected microwave signal from the device and a homodyne scheme recovers the effects of the incident THz radiation. Two modes of operation have been identified, depending on the level of incident radiation. For weak signals, we use a chopper to chop the incident radiation against a black body reference and a lock-in amplifier to perform synchronous detection of the homodyne readout. The voltage measured is proportional to the incident power, and we estimate an optical noise equivalent power of 5pW/ √Hz at 0.83 THz. At higher signal levels, the homodyne circuit recovers the stream of steady relaxation oscillation pulses from the HEB device. The frequency of these pulses is in the MHz frequency range and bears a linear relationship with the incident THz radiation over an input power range of 15 dB. A digital frequency counter is used to measure THz power. The applicable power range is between 1 nW and 1 μW.
|
Kawamura J, Blundell R, Tong C-YE, Papa DC, Hunter TR, Paine St. N, et al. Superconductive hot-electron bolometer mixer receiver for 800 GHz operation. Vol 48.; 2000.
|
Loudkov D, Tong CYE, Blundell R, Kaurova N, Grishina E, Voronov B, et al. An investigation of the performance of the superconducting HEB슠mixer as a function of its RF슠embedding impedance. IEEE Trans. Appl. Supercond.. 2005;15(2):472–5.
|
Tong CYE, Blundell R, Bumble B, Stern JA, LeDuc HG. Sub-Millimeter distributed quasiparticle receiver employing a non-Linear transmission line. In: Proc. 7th Int. Symp. Space Terahertz Technol.; 1996. 47.
|