|
Finkel MI, Maslennikov SN, Vachtomin YB, Svechnikov SI, Smirnov KV, Seleznev VA, et al. Hot electron bolometer mixer for 20 – 40 THz frequency range. In: Proc. 16th Int. Symp. Space Terahertz Technol. Göteborg, Sweden; 2005. p. 393–7.
Abstract: The developed HEB mixer was based on a 5 nm thick NbN film deposited on a GaAs substrate. The active area of the film was patterned as a 30×20 μm 2 strip and coupled with a 50 Ohm coplanar line deposited in situ. An extended hemispherical germanium lens was used to focus the LO radiation on the mixer. The responsivity of the mixer was measured in a direct detection mode in the 25÷64 THz frequency range. The noise performance of the mixer and the directivity of the receiver were investigated in a heterodyne mode. A 10.6 μm wavelength CW CO 2 laser was utilized as a local oscillator.
|
|
|
Gao JR, Hajenius M, Baselmans JJA, Klapwijk TM, de Korte PAJ, Voronov B, et al. NbN hot electron bolometer mixers with superior performance for space applications. In: Armandillo E, Leone B, editors. Proc. Int. workshop on low temp. electronics. Noordwijk; 2004. p. 11–7.
|
|
|
Gao JR, Hajenius M, Baselmans JJA, Yang ZQ, Baryshev AM, Barends R, et al. Twin-slot antenna coupled NbN hot electron bolometer mixers for space applications. In: Proc. 9-th WMSCI. Vol 9. International Institute of Informatics and Systemics; 2005. p. 148–53.
|
|
|
Gao JR, Hajenius M, Tichelaar FD, Voronov B, Grishina E, Klapwijk TM, et al. Can NbN films on 3C-SiC/Si change the IF bandwidth of hot electron bolometer mixers? In: Proc. 17th Int. Symp. Space Terahertz Technol.; 2006. p. 187–9.
Abstract: We realized ultra thin NbN films sputtered grown on a 3C-SiC/Si substrate. The film with a thickness of 3.5-4.5 nm shows a 1', of 11.8 K, which is the highest I`, observed among ultra thin NbN films on different substrates. The high-resolution transmission electron microscopy (HRTEM) studies show that the film has a monocrystalline structure, confirming the epitaxial growth on the 3C-SiC. Based on a two-temperature model and input parameters from standard NbN films on Si, simulations predict that the new film can increase the IF bandwidth of a HEB mixer by about a factor of 2 in comparison to the standard films. In addition, we find standard NbN films on Si with a T c of 9.4 K have a thickness of around 5.5 nm, being thicker than expected (3.5 nm).
|
|
|
Gao JR, Hiajenius M, Yang ZQ, Klapwijk TM, Miao W, Shi SC, et al. Direct comparison of the sensitivity of a spiral and a twin-slot antenna coupled HEB mixer at 1.6 THz. In: Proc. 17th Int. Symp. Space Terahertz Technol.; 2006. p. 59–62.
Abstract: To make a direct comparison of the sensitivity between a spiral and a twin slot antenna coupled HEB mixer, we designed both types of mixers and fabricated them in a single processing run and on the same wafer. Both mixers have similar dimensions of NbN bridges (1.5-2 pm x0.2 pm). At 1.6 THz we obtained a nearly identical receiver noise temperature from both mixers (only 5% difference), which is in a good agreement with the simulation based on semi analytical models for both antennas. In addition, by using a bandpass filter to reduce the direct detection effect and lowering the bath temperature to 2.4 K, we measured the lowest receiver noise temperature of 700 K at 1.63 THz using the twin-slot antenna mixer.
|
|