0kunev 0., Dzardanov A, Ekstrom H, Jacobsson S, Kollberg E, Gol'tsman G, et al. NbN hot electron waveguide mixer for 100 GHz operation. In: Proc. 5th Int. Symp. Space Terahertz Technol.; 1994. p. 214–24.
Abstract: NbN is a promising superconducting material used to develope hot- electron superconducting mixers with an IF bandwidth over 1 GHz. In the 100 GHz frequency range, the following parameters were obtained for NbN films 50 A thick: the noise temperature of the receiver (DSB) 1000 K; the conversion losses 10 d13, the IF bandwidth 1 GHz; the local oscillator power 1 /LW. An increase of NbN film thickness up to 80-100 A and increase of working temperature up to 7-8 K, and a better mixer matching may allow to broader the IF band up to 3 Gllz, to reduce the conversion losses down to 3-5 dB and the noise tempera- ture down to 200-300 K.
|
Anfertev V, Vaks V, Revin L, Pentin I, Tretyakov I, Goltsman G, et al. High resolution THz gas spectrometer based on semiconductor and superconductor devices. In: EPJ Web Conf. Vol 132.; 2017. 02001 (1 to 2).
Abstract: The high resolution THz gas spectrometer consists of a synthesizer based on Gunn generator with a semiconductor superlattice frequency multiplier as a radiation source, and an NbN hot electron bolometer in a direct detection mode as a THz radiation receiver was presented. The possibility of application of a quantum cascade laser as a local oscillator for a heterodyne receiver which is based on an NbN hot electron bolometer mixer is shown. The ways for further developing of the THz spectroscopy were outlined.
|
Antipov AV, Seleznev VA, Vakhtomin YB, Morozov PV, Vasilev DD, Malevannaya EI, et al. Investigation of WSi and NbN superconducting single-photon detectors in mid-IR range. In: IOP Conf. Ser.: Mater. Sci. Eng. Vol 781.; 2020. 012011 (1 to 5).
Abstract: Spectral characteristics of WSi and NbN superconducting single-photon detectors with different surface resistance and width of nanowire strips have been investigated in the wavelength range of 1.3-2.5 μm. WSi structures with narrower strips demonstrated better performance for detection of single photons in longer wavelength range. The difference in normalized photon count rate for such structures reaches one order of magnitude higher in comparison with structures based on NbN thin films at 2.5 μm.
|
Antipov SV, Vachtomin YB, Maslennikov SN, Smirnov KV, Kaurova NS, Grishina EV, et al. Noise performance of quasioptical ultrathin NbN hot electron bolometer mixer at 2.5 and 3.8 THz. In: Proc. 5-th MSMW. Vol 2. Kharkov, Ukraine; 2004. p. 592–4.
Abstract: To put space-based and airborne heterodyne instruments into operation at frequencies above 1 THz the superconducting NbN hot-electron bolometer (HEB) will be incorporated into heterodyne receiver as a mixer. At frequencies above 1.3 THz the sensitivity of the NbN HEB mixers outperform the one of the Schottky diodes and SIS-mixers, and the receiver noise temperature of the NbN HEB mixers increase with frequency. In this paper we present the results of the noise temperature measurements within one batch of NbN HEB mixers based on 3.5 mn thick superconducting NbN film grown on Si substrate with MgO buffer layer at the LO frequencies 2.5 THz and 3.8 THz.
|
Antipov SV, Svechnikov SI, Smirnov KV, Vakhtomin YB, Finkel MI, Goltsman GN, et al. Noise temperature of quasioptical NbN hot electron bolometer mixers at 900 GHz. Physics of Vibrations. 2001;9(4):242–5.
|