Dube I, Jiménez D, Fedorov G, Boyd A, Gayduchenko I, Paranjape M, et al. Understanding the electrical response and sensing mechanism of carbon-nanotube-based gas sensors. Carbon. 2015;87:330–7.
Abstract: Gas sensors based on carbon nanotube field effect transistors (CNFETs) have outstanding sensitivity compared to existing technologies. However, the lack of understanding of the sensing mechanism has greatly hindered progress on calibration standards and customization of these nano-sensors. Calibration requires identifying fundamental transistor parameters and establishing how they vary in the presence of a gas. This work focuses on modeling the electrical response of CNTFETs in the presence of oxidizing (NO2) and reducing (NH3) gases and determining how the transistor characteristics are affected by gas-induced changes of contact properties, such as the Schottky barrier height and width, and by the doping level of the nanotube. From the theoretical fits of the experimental transfer characteristics at different concentrations of NO2 and NH3, we find that the CNTFET response can be modeled by introducing changes in the Schottky barrier height. These changes are directly related to the changes in the metal work function of the electrodes that we determine experimentally, independently, with a Kelvin probe. Our analysis yields a direct correlation between the ON – current and the changes in the electrode metal work function. Doping due to molecules adsorbed at the carbon-nanotube/metal interface also affects the transfer characteristics.
|
|
|
Akhmadishina KF, Bobrinetskiy II, Komarov IA, Malovichko AM, Nevolin VK, Fedorov GE, et al. Fast-response biological sensors based on single-layer carbon nanotubes modified with specific aptamers. Semicond. 2015;49(13):1749–53.
Abstract: The possibility of the fabrication of a fast-response biological sensor based on a composite of single-layer carbon nanotubes and aptamers for the specific detection of proteins is shown. The effect of modification of the surface of the carbon nanotubes on the selectivity and sensitivity of the sensors is investigated. It is shown that carboxylated nanotubes have a better selectivity for detecting thrombin.
|
|
|
Чулкова ГМ, Корнеев АА, Смирнов КВ, Окунев ОВ. Энергетическая релаксация в примесных металлах, двумерном электронном газе в AlGaAs-GaAs, сверхпроводниковых пленках NbN и детекторы субмиллиметрового и ик излучения на их основе. Прометей, МПГУ; 2012.
Abstract: Монография посвящена обзору исследований влияния эффектов электронного беспорядка на электронное взаимодействие в металлах, сверхпроводниках, полупроводниках, а также в различных низкоразмерных структурах. Актуальность поднятых в монографии вопросов определяется интенсивным развитием нанотехнологий, созданием новых наноструктурированных материалов и уникальных наноэлементов для электроники и фотоники. Упругое электронное рассеяние на границах наноструктур качественно меняет взаимодействие электронов с фонолами, что, безусловно, должно учитываться при проектировании соответствующей элементной базы. Прикладная часть работы посвящена контролируемой модификации электронных процессов для оптимизации новых наносенсоров на основе электронного разогрева в сверхпроводниковых и полупроводниковых структурах. Монография предназначена для студентов старших курсов, аспирантов и начинающих следователей, работающих в области сверхпроводниковой наноэлектроники.
|
|
|
Danerud M, Winkler D, Zorin M, Trifonov V, Karasik B, Gershenzon EM, et al. Picosecond detection of infrared radiation with YBa2Cu3O7-δ thin films. In: Birch JR, Parker TJ, editors. Proc. SPIE. Vol 2104. Spie; 1993. p. 183–4.
Abstract: Picosecond nonequilibrium and slow bolometric responses from a patterned high-Tc superconducting (HTS) film due toinfrared radiation were investigated using both modulation and pulse techniques. Measurements at A, = 0.85 [tm andA, = 10.6 lim have shown a similar behaviour of the response vs modulation frequency f. The responsivity of the HTS filmbased detector at f ..- 0.6-1 GHz is estimated to be 10-2 – 10-1 V/W.
|
|
|
Fedorov G, Gayduchenko I, Titova N, Moskotin M, Obraztsova E, Rybin M, et al. Graphene-based lateral Schottky diodes for detecting terahertz radiation. In: Berghmans F, Mignani AG, editors. Proc. Optical Sensing and Detection V. Vol 10680. Spie; 2018. p. 30–9.
Abstract: Demand for efficient terahertz radiation detectors resulted in intensive study of the carbon nanostructures as possible solution for that problem. In this work we investigate the response to sub-terahertz radiation of graphene field effect transistors of two configurations. The devices of the first type are based on single layer CVD graphene with asymmetric source and drain (vanadium and gold) contacts and operate as lateral Schottky diodes (LSD). The devices of the second type are made in so-called Dyakonov-Shur configuration in which the radiation is coupled through a spiral antenna to source and top electrodes. We show that at 300 K the LSD detector exhibit the room-temperature responsivity from R = 15 V/W at f= 129 GHz to R = 3 V/W at f = 450 GHz. The DS detector responsivity is markedly lower (2 V/W) and practically frequency independent in the investigated range. We find that at low temperatures (77K) the graphene lateral Schottky diodes responsivity rises with the increasing frequency of the incident sub-THz radiation. We interpret this result as a manifestation of a plasmonic effect in the devices with the relatively long plasmonic wavelengths. The obtained data allows for determination of the most promising directions of development of the technology of nanocarbon structures for the detection of THz radiation.
|
|