Records |
Author |
Gousev, Yu. P.; Olsson, H. K.; Gol'tsman, G. N.; Voronov, B. M.; Gershenzon, E. M. |
Title |
NbN hot-electron mixer at radiation frequencies between 0.9 THz and 1.2 THz |
Type |
Conference Article |
Year |
1998 |
Publication |
Proc. 9th Int. Symp. Space Terahertz Technol. |
Abbreviated Journal |
Proc. 9th Int. Symp. Space Terahertz Technol. |
Volume |
|
Issue |
|
Pages |
121-129 |
Keywords |
NbN HEB mixers |
Abstract |
We report on noise temperature measurements for a NbN phonon-cooled hot-electron mixer at radiation frequencies between 0.9 THz and 1.2 THz. Radiation was coupled to the mixer, placed in a vacuum chamber of He cryostat, by means of a planar spiral antenna and a Si immersion lens. A backward-wave oscillator, tunable throughout the spectral range, delivered an output power of few 1.1W that was enough for optimum operation of the mixer. At 4.2 K ambient temperature and 1.025 THz radiation frequency, we obtained a receiver noise temperature of 1550 K despite of using a relatively noisy room-temperature amplifier at the intermediate frequency port. The noise temperature was fairly constant throughout the entire operation range and for intermediate frequencies from 1 GHz to 2 GHz. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1588 |
Permanent link to this record |
|
|
|
Author |
Aksaev, E. E.; Gershenzon, E.M.; Gol'tsman, G. N.; Mirskij, G. I.; Semenov, A. D. |
Title |
Submillimetric spectrometer-relaxometer based on backward-wave tubes with picosecond time resolution |
Type |
Journal Article |
Year |
1991 |
Publication |
Pribory i Tekhnika Eksperimenta |
Abbreviated Journal |
Pribory i Tekhnika Eksperimenta |
Volume |
34 |
Issue |
2 |
Pages |
125-131 |
Keywords |
BWO, applications |
Abstract |
The high-sensitive automatic spectrometer-relaxometer based on backward-wave tubes in the range of 4÷0.25 mm was described permitting to study the response kinetics of sample under investigation in any point of this range with the resolution time of 10-11 s. The relaxation measurements were conducted using oscillation beats of two adequate tubes, the frequency of one of them was fixed, while that of the other one was changeable. The amplitude-frequency characteristic of the response under the conditions of synchronous reception was recorded at beat frequency variation from 107 to 1010 Hz. The high sensitivity was reached by decreasing the device recording band down to 100 Hz in the whole measuring range. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0032-8162 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1683 |
Permanent link to this record |
|
|
|
Author |
Gershenzon, E. M.; Gol'tsman, G. N.; Mirskii, G. I. |
Title |
Submillimeter backward-wave-tube spectrometer-relaxometer |
Type |
Journal Article |
Year |
1987 |
Publication |
Pribory i Tekhnika Eksperimenta |
Abbreviated Journal |
Pribory i Tekhnika Eksperimenta |
Volume |
30 |
Issue |
4 |
Pages |
131-137 |
Keywords |
BWO, applications |
Abstract |
A backward-wave-tube (BWT) spectrometer-relaxometer is described that is designed for study of the relaxation characteristics of photoconductors in the wavelength range of 2-0.25 mm – in particular, to measure the relaxation times of the submillimeter photoconductivity of germanium in the range of 10[sup:-4]-10[sup:-9] sec and to determine from these data the concentration of compensating impurities of from 10[sup:10] to 10[sup:14] cm[sup:-3]. The instrument uses the beats of the oscillations of two BWTs and records the amplitude-frequency response of the specimen with variation of the beat frequency from 10[sup:4] to 10[sup:8] Hz with accumulation of the desired signal for less than or equal to1 sec by means of a quadrature synchronous detector. The beat frequency is stabilized and the quadrature voltages of the synchronous detector are formed by means of phase-locked loops. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
Russian |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1699 |
Permanent link to this record |
|
|
|
Author |
Gershenzon, E. M.; Gol'tsman, G. N.; Semenov, A. D. |
Title |
Submillimeter backward wave tube spectrometer for measuring superconducting film transmission |
Type |
Journal Article |
Year |
1983 |
Publication |
Pribory i Tekhnika Eksperimenta |
Abbreviated Journal |
Pribory i Tekhnika Eksperimenta |
Volume |
26 |
Issue |
5 |
Pages |
134-137 |
Keywords |
BWO spectroscopy, spectrometer, transmission |
Abstract |
A spectrometer employing six backward wave tubes is described. It is intended for investigation of superconductors in the 0.2-3 mm range of wave lengths. During the measurement of the transmission spectrum it is possible to determine the energy gap for superconduct1ng films 50 to 4000 A thick. The transmission factor can vary from 10-1 to 10-9. Spectrum of relation of film transmission factors in superconducting and normal states is measured for determining the energy gap 2 Δ. The transmission spectrum obtained by means of a computer for vanadium film 300 A thick is given as an example. The energy gap 2 Δ = 1.4 MeV |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
Russian |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0032-8162 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
Субмиллиметровый спектрометр с лампами обратной волны для измерения пропускания сверхпроводниковых пленок |
Approved |
no |
Call Number |
|
Serial |
1713 |
Permanent link to this record |
|
|
|
Author |
Ryabchun, S. A.; Tretyakov, I. V.; Finkel, M. I.; Maslennikov, S. N.; Kaurova, N. S.; Seleznev, V. A.; Voronov, B. M.; Gol'tsman, G. N. |
Title |
NbN phonon-cooled hot-electron bolometer mixer with additional diffusion cooling |
Type |
Conference Article |
Year |
2009 |
Publication |
Proc. 20th Int. Symp. Space Terahertz Technol. |
Abbreviated Journal |
Proc. 20th ISSTT |
Volume |
|
Issue |
|
Pages |
151-154 |
Keywords |
HEB, mixer, bandwidth, noise temperatue, in-situ contacts, in situ contacts |
Abstract |
|
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Charlottesville, USA |
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
590 |
Permanent link to this record |