Manova NN, Simonov NO, Korneeva YP, Korneev AA. Developing of NbN films for superconducting microstrip single-photon detector. In: J. Phys.: Conf. Ser. Vol 1695.; 2020. 012116 (1 to 5).
Abstract: We optimized NbN films on a Si substrate with a buffer SiO2 layer to produce superconducting microstrip single-photon detectors with saturated dependence of quantum efficiency (QE) versus normalized bias current. We varied thickness of films and observed the maximum QE saturation for device based on the thinner film with the lowest ratio RS300/RS20.
|
Polyakova MI, Korneev AA, Semenov AV. Comparison single- and double- spot detection efficiencies of SSPD based to MoSi and NbN films. In: J. Phys.: Conf. Ser. Vol 1695.; 2020. 012146 (1 to 3).
Abstract: In this work, we present results of quantum detector tomography of superconducting single photon detector (SSPD) based on MoSi film, and compare them with previously reported data on NbN. We find that for both materials hot spot interaction length coincides with the strip width, and the dependence of single and double-spot detection efficiencies on bias current are compatible with sufficiently large hot-spot size, approaching the strip width.
|
Casaburi A, Ejrnaes M, Quaranta O, Gaggero A, Mattioli F, Leoni R, et al. Experimental characterization of NbN nanowire optical detectors with parallel stripline configuration. In: J. Phys.: Conf. Ser. Vol 97. IOP Publishing; 2008. 012265 (1 to 6).
Abstract: We have developed a novel geometrical configuration for NbN-based superconducting single photon optical detector (SSPD) that achieves two goals: a much lower intrinsic impedance, and a consequently greater bandwidth, and a much larger signal amplitude compared to the standard meandered configuration. This has been obtained by implementing a properly designed parallel stripline structure where a cascade switching mechanism occurs when one of the striplines is hit by an optical photon. The overall switching occurs synchronously and in a very short time, giving rise to a strong and fast voltage pulse. The SSPD have been realized using state of the art NbN deposition technology and e-beam lithography. The strips are 100 nm wide and 5 μm long and have been realized with 4 nm NbN film on sapphire and Si substrate. We report on experimental characterization of such novel devices. The performances of the proposed novel type of SSPD are compared with standard SSPD design and results in terms of signal amplitude, risetime and effective detection area.
|
Baeva E, Sidorova M, Korneev A, Goltsman G. Precise measurement of the thermal conductivity of superconductor. In: Proc. AIP Conf. Vol 1936.; 2018. 020003 (1 to 4).
Abstract: Measuring the thermal properties such as the heat capacity provide information about intrinsic mechanisms operated inside. In general, the ratio between electron and phonon specific heat Ce/Cp shows how the absorbed energy shared between electron and phonon subsystems. In this work we make estimations for amplitude-modulated absorption of THz radiation technique for investigation of the ratio Ce/Cp in superconducting Niobium Nitride (NbN) at T = Tc. Our results indicates that experimentally the frequency of modulation has to be extra large to extract the quantity. We perform a new technique allowed to work at low frequency with accurately measurement of absorbed power.
|
Smirnov K, Divochiy A, Vakhtomin Y, Morozov P, Zolotov P, Antipov A, et al. NbN single-photon detectors with saturated dependence of quantum efficiency. Supercond Sci Technol. 2018;31(3):035011 (1 to 8).
Abstract: The possibility of creating NbN superconducting single-photon detectors with saturated dependence of quantum efficiency (QE) versus normalized bias current was investigated. It was shown that the saturation increases for the detectors based on finer films with a lower value of Rs300/Rs20. The decreasing of Rs300/Rs20 was related to the increasing influence of quantum corrections to conductivity of superconductors and, in turn, to the decrease of the electron diffusion coefficient. The best samples have a constant value of system QE 94% at Ib/Ic ~ 0.8 and wavelength 1310 nm.
|