|
Yagoubov P, Hoogeveen R, Torgashin M, Khudchenko A, Koshelets V, Suttiwong N, et al. 550-650 GHz spectrometer development for TELIS. In: Proc. 17th Int. Symp. Space Terahertz Technol.; 2006. p. 338–41.
|
|
|
Koshelets VP, Ermakov AB, Filippenko LV, Khudchenko AV, Kiselev OS, Sobolev AS, et al. Superconducting integrated submillimeter receiver for TELIS. IEEE Trans. Appl. Supercond.. 2007;17(2):336–42.
|
|
|
Yagoubov P, Gol'tsman G, Voronov B, Svechnikov S, Cherednichenko S, Gershenzon E, et al. Quasioptical phonon-cooled NbN hot-electron bolometer mixer at THz frequencies. In: Proc. 7th Int. Symp. Space Terahertz Technol.; 1996. p. 303–17.
Abstract: In our experiments we tested phonon-cooled hot-electron bolometer (HEB) quasioptical mixer based on spiral antenna designed for 0.5-1.2 THz frequency band and fabricated on sapphire, Si-coated sapphire and high resistivity silicon substrates. HEB devices were produced from thin superconducting NbN film 3.5-6 nm thick with the critical temperature of about 11-12 K. For these devices we achieved the receiver noise temperature T R (DSB) = 3000 K in the 500-700 GHz frequency range and an IF bandwidth of 3-4 GHz. Prelimanary measurements at frequencies 1-1.2 THz resulted the receiver noise temperature about 9000 K (DSB).
|
|
|
Merkel HF, Yagoubov PA, Kroug M, Khosropanah P, Kollberg EL, Gol’tsman GN, et al. Noise temperature and absorbed LO power measurement methods for NbN phonon-cooled hot electron bolometric mixers at terahertz frequencies. In: Proc. 28th European Microwave Conf. Vol 1.; 1998. p. 294–9.
Abstract: In this paper the absorbed LO power requirements and the noise performance of NbN based phonon-cooled hot electron bolometric (HEB) quasioptical mixers are investigated for RF frequencies in the 0.55-1.1 range The minimal measured DSB noise temperatures are about 500 K at 640 GHz, 600 K at 750 GHz, 850 K at 910 GHz and 1250 K at 1.1 THz. The increase in noise temperature at 1.1THz is attributed to water absorption. The absorbed LO power is measured using a calorimetric approach. The results are subsequently corrected for lattice heating. These values are compared to results of a novel one dimensional hot spot mixer models and to a more traditional isotherm method which tends to underestimate the absorbed LO power for small bias powers. Typically a LO power between 50nW and 100nW is needed to pump the device to the optimal operating point.
|
|
|
Semenov AD, Gousev YP, Nebosis RS, Renk KF, Yagoubov P, Voronov BM, et al. Heterodyne detection of THz radiation with a superconducting hot‐electron bolometer mixer. Appl Phys Lett. 1996;69(2):260–2.
Abstract: We report on the use of a superconducting hot‐electron bolometer mixer for heterodyne detection of terahertz radiation. Radiation with a wavelength of 119 μm was coupled to the mixer, a NbN microbridge, by a hybrid quasioptical antenna consisting of an extended hyperhemispherical lens and a planar logarithmic spiral antenna. We found, at an intermediate frequency of 1.5 GHz, a system double side band noise temperature of ≊40 000 K and conversion losses of 25 dB. We also discuss the possibilities of further improvement of the mixer performance.
|
|