Records |
Author |
Gol'tsman, G. N.; Semenov, A. D.; Gousev, Y. P.; Zorin, M. A.; Gogidze, I. G.; Gershenzon, E. M.; Lang, P. T.; Knott, W. J.; Renk, K. F. |
Title |
Sensitive picosecond NbN detector for radiation from millimetre wavelengths to visible light |
Type |
Journal Article |
Year |
1991 |
Publication |
Supercond. Sci. Technol. |
Abbreviated Journal |
Supercond. Sci. Technol. |
Volume |
4 |
Issue |
9 |
Pages ![sorted by First Page field, descending order (down)](img/sort_desc.gif) |
453-456 |
Keywords |
NbN HEB detectors |
Abstract |
The authors report on the application of a broad-band NbN film detector which has high sensitivity and picosecond response time for detection of radiation from millimetre wavelengths to visible light. From a study of amplitude modulated radiation of backward-wave tubes and picosecond pulses from gas and solid state lasers at wavelengths between 2 mm and 0.53 mu m, they found a detectivity of 1010 W-1 cm Hz-1/2 and a response time of less than 50 ps at T=10 K. The characteristics were provided by using a 150 AA thick NbN film patterned into a structure of micron strips. According to the proposed detection mechanism, namely electron heating, they expect an intrinsic response time of approximately 20 ps at the same temperature. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0953-2048 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
242 |
Permanent link to this record |
|
|
|
Author |
Danerud, M.; Winkler, D.; Zorin, M.; Trifonov, V.; Karasik, B.; Gershenzon, E. M.; Gol'tsman, G. N.; Lindgren, M. |
Title |
Picosecond detection of infrared radiation with YBa2Cu3O7-δ thin films |
Type |
Conference Article |
Year |
1993 |
Publication |
Proc. SPIE |
Abbreviated Journal |
Proc. SPIE |
Volume |
2104 |
Issue |
|
Pages ![sorted by First Page field, descending order (down)](img/sort_desc.gif) |
183-184 |
Keywords |
YBCO HTS HEB detectors |
Abstract |
Picosecond nonequilibrium and slow bolometric responses from a patterned high-Tc superconducting (HTS) film due toinfrared radiation were investigated using both modulation and pulse techniques. Measurements at A, = 0.85 [tm andA, = 10.6 lim have shown a similar behaviour of the response vs modulation frequency f. The responsivity of the HTS filmbased detector at f ..- 0.6-1 GHz is estimated to be 10-2 – 10-1 V/W. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
Spie |
Place of Publication |
|
Editor |
Birch, J.R.; Parker, T.J. |
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
18th International Conference on Infrared and Millimeter Waves |
Notes |
https://inis.iaea.org/search/searchsinglerecord.aspx?recordsFor=SingleRecord&RN=25034664 |
Approved |
no |
Call Number |
10.1117/12.2298489 |
Serial |
1653 |
Permanent link to this record |
|
|
|
Author |
Shurakov, A.; Tong, Cheuk-yu E.; Grimes, P.; Blundell, R.; Golt'sman, G. |
Title |
A microwave reflection readout scheme for hot electron bolometric direct detector |
Type |
Journal Article |
Year |
2015 |
Publication |
IEEE Trans. THz Sci. Technol. |
Abbreviated Journal |
IEEE Trans. THz Sci. Technol. |
Volume |
5 |
Issue |
|
Pages ![sorted by First Page field, descending order (down)](img/sort_desc.gif) |
81-84 |
Keywords |
HEB detectors |
Abstract |
In this paper, we propose and present data from a fast THz detector based on the repurpose of hot electron bolometer mixers (HEB) fabricated from superconducting NbN thinfilm. This detector is essentially a traditional NbN bolometer element that operates under the influence of a microwave pump. The in-jected microwave power serves the dual purpose of enhancing the detector sensitivity and reading out the impedance changes of the device in response to incidentTHz radiation. We have measured an optical Noise Equivalent Power of 4 pW/ Hz for our detector at a bath temperature of 4.2 K. The measurement frequency was 0.83 THz and the modulation frequency was 1.48 kHz. The readout
scheme is versatile and facilitates both high-speed operation as well as multi-pixel applications. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
RPLAB @ atomics90 @ |
Serial |
950 |
Permanent link to this record |