Kroug M, Cherednichenko S, Choumas M, Merkel H, Kollberg E, Hübers H-W, et al. HEB quasi-optical heterodyne receiver for THz frequencies. In: Proc. 12th Int. Symp. Space Terahertz Technol. San Diego, CA, USA; 2001. p. 244–52.
|
Richter H, Semenov A, Hubers H-W, Smirnov K, Gol’tsman G, Voronov B. Phonon cooled hot-electron bolometric mixer for 1-5 THz. In: Proc. 29th IRMMW / 12th THz.; 2004. p. 241–2.
Abstract: Heterodyne receivers for applications in astronomy and planetary research need quantum limited sensitivity. In instruments which are currently built for SOFIA and Herschel, superconducting hot electron bolometers (HEB) are used to achieve this goal at frequencies above 1.4 THz. In order to optimize the performance for this frequency of hot electron bolometer mixers with different in-plane dimensions and logarithmic-spiral feed antennas have been investigated. Their noise temperatures and beam patterns were measured. Above 3 THz the best performance was achieved with a superconducting bridge of 2.0/spl times/0.2 /spl mu/m/sup 2/ incorporated in a logarithmic spiral antenna. The DSB noise temperatures were 2700 K, 4700 and 6400 K at 3.1 THz, 4.3 THz and 5.2 THz, respectively. The results demonstrate that the NbN HEB is very well suited as a mixer for THz heterodyne receivers up to at least 5 THz.
|
Semenov AD, Richter H, Hubers H-W, Gunther B, Smirnov A, Il'in KS, et al. Terahertz performance of integrated lens antennas with a hot-electron bolometer. IEEE Trans. Microw. Theory Techn.. 2007;55(2):239–47.
|
Yagoubov P, Kroug M, Merkel H, Kollberg E, Hübers H-W, Schubert J, et al. NbN hot electron bolometric mixers at frequencies between 0.7 and 3.1 THz. In: Proc. 10th Int. Symp. Space Terahertz Technol.; 1999. p. 238–46.
Abstract: The performance of NbN based phonon-cooled Hot Electron Bolometric (HEB) quasioptical mixers is investigated in the 0.7-3.1 THz frequency range. The devices are made from a 3.5-4 nm thick NbN film on high resistivity Si and integrated with a planar spiral antenna on the same substrate. The length of the bolometer microbridge is 0.1- 0.2 gm, the width is 1-2 gm. The best results of the DSB receiver noise temperature measured at 1.5 GHz intermediate frequency are: 800 K at 0.7 THz, 1100 K at 1.6 THz, 2000 K at 2.5 THz and 4200 K at 3.1 THz. The measurements were performed with a far infrared laser as the local oscillator (LO) source. The estimated LO power required is less than 500 nW at the receiver input. First results on the spiral antenna polarization measurements are reported.
|
Tong C-YE, Meledin DV, Marrone DP, Paine SN, Gibson H, Blundell R. Near field vector beam measurements at 1 THz. IEEE Microw. Compon. Lett.. 2003;13(6):235–7.
Abstract: We have performed near-field vector beam measurements at 1.03 THz to characterize and align the receiver optics of a superconducting receiver. The signal source is a harmonic generator mounted on an X-Y translation stage. We model the measured two-dimensional complex beam pattern by a fundamental Gaussian mode, from which we derive the position of the beam center, the beam radius and the direction of propagation. By performing scans in the planes separated by 400 mm, we have confirmed that our beam pattern measurements are highly reliable.
|