Vetter A, Ferrari S, Rath P, Alaee R, Kahl O, Kovalyuk V, et al. Cavity-enhanced and ultrafast superconducting single-photon detectors. Nano Lett. 2016;16(11):7085–92.
Abstract: Ultrafast single-photon detectors with high efficiency are of utmost importance for many applications in the context of integrated quantum photonic circuits. Detectors based on superconductor nanowires attached to optical waveguides are particularly appealing for this purpose. However, their speed is limited because the required high absorption efficiency necessitates long nanowires deposited on top of the waveguide. This enhances the kinetic inductance and makes the detectors slow. Here, we solve this problem by aligning the nanowire, contrary to usual choice, perpendicular to the waveguide to realize devices with a length below 1 mum. By integrating the nanowire into a photonic crystal cavity, we recover high absorption efficiency, thus enhancing the detection efficiency by more than an order of magnitude. Our cavity enhanced superconducting nanowire detectors are fully embedded in silicon nanophotonic circuits and efficiently detect single photons at telecom wavelengths. The detectors possess subnanosecond decay ( approximately 120 ps) and recovery times ( approximately 510 ps) and thus show potential for GHz count rates at low timing jitter ( approximately 32 ps). The small absorption volume allows efficient threshold multiphoton detection.
|
Jiang L, Li J, Zhang W, Yao QJ, Lin ZL, Shi SC, et al. Characterization of NbN HEB mixers cooled by a close-cycled 4 Kelvin refrigerator. IEEE Trans Appl Supercond. 2005;15(2):511–3.
Abstract: It is quite beneficial to operate superconducting hot-electron-bolometer (HEB) mixers with a close-cycled 4 Kelvin refrigerator for real applications such as astronomy and atmospheric research. In this paper, a phononcooled NbN HEB mixer (quasioptical type) is thoroughly characterized under such a cooling circumstance. The effects of mechanical vibration, electrical interference, and temperature fluctuation of a two-stage Gifford-McMahon 4 Kelvin refrigerator upon the characteristics of the phononcooled NbN HEB mixer are investigated in particular. Detailed measurement results are presented.
|
Ozhegov RV, Smirnov AV, Vakhtomin YB, Smirnov KV, Divochiy AV, Goltsman GN. Ultrafast superconducting bolometer receivers for terahertz applications [abstract]. In: Proc. PIERS. 777 Concord Avenue, Suite 207 Cambridge, MA 02138: The Electromagnetics Academy; 2009. 867.
Abstract: The research by the group of Moscow State Pedagogical University into the hot-electron phenomena in thin superconducting films has led to the development of new types of detectors and their use both in fundamental and applied studies. In this paper, we present the results of testing the terahertz HEB receiver systems based on ultrathin (∼ 4 nm) NbN and MoRe detectors with a response time of 50 ps and 1 ns, respectively. We have developed three types of devices which differ in the way a terahertz signal is coupled to the detector and cover the following ranges: 0.3–3 THz, 0.1–30 THz and 25–70 THz. In the case of the receiving system optimized for 0.3–3 THz, the sensitive element (a strip of asuperconductor with planar dimensions of 0.2μm (length) by 1.7μm (width)) was integrated witha planar broadband log-spiral antenna. For additional focusing ofthe incident radiation a silicon hyperhemispherical lens was used. For the 0.1–30 THz receivingsystem, the sensitive element was patterned as parallel strips(2μm wide each) filling an area of 500×500μm2with a filling factor of 0.5. In the receivingsystem of this type we used direct coupling of the incident radiation to the sensitive element. Inthe 25–70 THz range (detector type 2/2a in Table 1) we used a square-shaped superconductingdetector with planar dimensions of 10×10μm2. Incident radiation was coupled to the detectorwith the use of a germanium hyperhemispherical lens.The response time of the above receiving systems is determined by the cooling rate of the hotelectrons in the film. That depends on the electron-phonon interaction time, which is less forultrathin NbN than in MoRe.
|
Titova NA, Baeva EM, Kardakova AI, Goltsman GN. Fabrication of NbN/SiNx:H/SiO2 membrane structures for study of heat conduction at low temperatures. In: J. Phys.: Conf. Ser. Vol 1695.; 2020. 012190.
Abstract: Here we report on the development of NbN/SiNx:H/SiO2-membrane structures for investigation of the thermal transport at low temperatures. Thin NbN films are known to be in the regime of a strong electron-phonon coupling, and one can assume that the phononic and electronic baths in the NbN are in local equilibrium. In such case, the cooling of the NbN-based devices strongly depends on acoustic matching to the substrate and substrate thermal characteristics. For the insulating membrane much thicker than the NbN film, our preliminary results demonstrate that the membrane serves as an additional channel for the thermal relaxation of the NbN sample. That implies a negligible role of thermal boundary resistance of the NbN-SiNx:H interface in comparison with the internal thermal resistance of the insulating membrane.
|
Venediktov IO, Elezov MS, Prokhodtsov AI, Kovalyuk VV, An PP, Golikov AD, et al. Study of microheater’s phase modulation for on-chip Kennedy receiver. In: J. Phys.: Conf. Ser. Vol 1695.; 2020. 012117.
Abstract: In this work we describe phase modulators for several Mach-Zehnder interferometers (MZI) on silicon nitride platform for telecomm wavelength (1550 nm). We obtained current-voltage and phase-voltage curves for these modulators. MZI are needed for experimental realisation of various quantum receivers that can distinguish weak coherent states of light with extremely low error. Thermo-optical (TO) modulation is ensured by microheaters on one of the arms of MZI, which enables the change of the refractive index of the material with temperature. This approach allows to apply the necessary voltage to the golden microheaters to obtain the required phase change. For the on-chip microheaters we demonstrate the dependence of the phase shift on the voltage applied to our on-chip microheaters.
|