Korneeva Y, Florya I, Vdovichev S, Moshkova M, Simonov N, Kaurova N, et al. Comparison of hot spot formation in nbn and mon thin superconducting films after photon absorption. IEEE Trans Appl Supercond. 2017;27(4):1–4.
Abstract: In superconducting single-photon detectors (SSPD), the efficiency of local suppression of superconductivity and hotspot formation is controlled by diffusivity and electron-phonon interaction time. Here, we selected a material, 3.6-nm-thick MoNx film, which features diffusivity close to those of NbN traditionally used for SSPD fabrication, but with electron-phonon interaction time an order of magnitude larger. In MoN ∞ detectors, we study the dependence of detection efficiency on bias current, photon energy, and strip width, and compare it with NbN SSPD. We observe nonlinear current-energy dependence in MoNx SSPD and more pronounced plateaus in dependences of detection efficiency on bias current, which we attribute to longer electron-phonon interaction time.
|
|
|
Корнеева ЮП, Михайлов ММ, Манова НН, Дивочий АА, Корнеев АА, Вахтомин ЮБ, et al. Сверхпроводниковый однофотонный детектор на основе аморфных пленок MoSi. In: Труды XVIII международного симпозиума «Нанофизика и наноэлектроника». Vol 1.; 2014. p. 53–4.
Abstract: Нами были изготовлены и исследованы однофотонные детекторы на основе сверхпроводящих пленок Mo x Si 1-x двух различных стехиометрий: Mo 3 Si и Mo 4 Si. При температуре 1.7 К лучшие детекторы площадью 7 мкм*7 мкм на основе этих пленок продемонстрировали системную квантовую эффективность 18% при скорости темнового счета 10 с -1 на длине волны 1.2 мкм с использованием неполяризованного источника, длительность импульса – 6 нс, джиттер – 120 пс.
|
|
|
Korneeva YP, Manova NN, Florya IN, Mikhailov MY, Dobrovolskiy OV, Korneev AA, et al. Different single-photon response of wide and narrow superconducting MoxSi1−x strips. Phys Rev Applied. 2020;13(2):024011 (1 to 7).
Abstract: The photon count rate (PCR) of superconducting single-photon detectors made of MoxSi1−x films shaped as a 2-μm-wide strip and a 115-nm-wide meander strip line is studied experimentally as a function of the dc biasing current at different values of the perpendicular magnetic field. For the wide strip, a crossover current Icross is observed, below which the PCR increases with an increasing magnetic field and above which it decreases. This behavior contrasts with the narrow MoxSi1−x meander, for which no crossover current is observed, thus suggesting different photon-detection mechanisms in the wide and narrow strips. Namely, we argue that in the wide strip the absorbed photon destroys superconductivity locally via the vortex-antivortex mechanism for the emergence of resistance, while in the narrow meander superconductivity is destroyed across the whole strip line, forming a hot belt. Accordingly, the different photon-detection mechanisms associated with vortices and the hot belt determine the qualitative difference in the dependence of the PCR on the magnetic field.
|
|
|
Korneeva Y, Sidorova M, Semenov A, Krasnosvobodtsev S, Mitsen K, Korneev A, et al. Comparison of hot-spot formation in NbC and NbN single-photon detectors. IEEE Trans Appl Supercond. 2016;26(3):1–4.
Abstract: We report an experimental investigation of the hot-spot evolution in superconducting single-photon detectors made of disordered superconducting materials with different diffusivity and energy downconversion time values, i.e., 33-nm-thick NbN and 23-nm-thick NbC films. We have demonstrated that, in NbC film, only 405-nm photons produce sufficiently large hot spot to trigger a single-photon response. The dependence of detection efficiency on bias current for 405-nm photons in NbC is similar to that for 3400-nm photons in NbN. In NbC, large diffusivity and downconversion time result in 1-D critical current suppression profile compared with the usual 2-D profile in NbN.
|
|
|
Moshkova M, Divochiy A, Morozov P, Vakhtomin Y, Antipov A, Zolotov P, et al. High-performance superconducting photon-number-resolving detectors with 86% system efficiency at telecom range. J Opt Soc Am B. 2019;36(3):B20.
Abstract: The use of improved fabrication technology, highly disordered NbN thin films, and intertwined section topology makes it possible to create high-performance photon-number-resolving superconducting single-photon detectors (PNR SSPDs) that are comparable to conventional single-element SSPDs at the telecom range. The developed four-section PNR SSPD has simultaneously an 86±3% system detection efficiency, 35 cps dark count rate, ∼2 ns dead time, and maximum 90 ps jitter. An investigation of the PNR SSPD’s detection efficiency for multiphoton events shows good uniformity across sections. As a result, such a PNR SSPD is a good candidate for retrieving the photon statistics for light sources and quantum key distribution systems.
|
|