|
Stevens MJ, Baek B, Dauler EA, Kerman AJ, Molnar RJ, Hamilton SA, et al. High-order temporal coherences of
chaotic and laser light. Opt Express. 2010;18(2):1430–7.
Abstract: We demonstrate a new approach to measuring high-order temporal coherences that uses a four-element superconducting nanowire single-photon detector. The four independent, interleaved single-photon-sensitive elements parse a single spatial mode of an optical beam over dimensions smaller than the minimum diffraction-limited spot size. Integrating this device with four-channel time-tagging electronics to generate multi-start, multi-stop histograms enables measurement of temporal coherences up to fourth order for a continuous range of all associated time delays. We observe high-order photon bunching from a chaotic, pseudo-thermal light source, measuring maximum third- and fourth-order coherence values of 5.87 ± 0.17 and 23.1 ± 1.8, respectively, in agreement with the theoretically predicted values of 3! = 6 and 4! = 24. Laser light, by contrast, is confirmed to have coherence values of approximately 1 for second, third and fourth orders at all time delays.
|
|
|
Zhong T, Hu X, Wong FNC, Berggren KK, Roberts TD, Battle P. High-quality fiber-optic polarization entanglement distribution at 1.3 μm telecom wavelength. Opt Lett. 2010;35(9):1392–4.
Abstract: We demonstrate high-quality distribution of 1.3 μm polarization-entangled photons generated from a fiber-coupled periodically poled KTiOPO4 waveguide over 200 m fiber-optic cables. Time-multiplexed measurements with a 19% efficient superconducting nanowire single-photon detector at the remote location show a detected flux of 5.8 pairs / s at a pump power of 25 μW and an average two-photon quantum-interference visibility of 97.7% without subtraction of accidentals.
|
|
|
Mannino G, Spinella C, Ruggeri R, La Magna A, Fisicaro G, Fazio E, et al. Crystallization of implanted amorphous silicon during millisecond annealing by infrared laser irradiation. Appl Phys Lett. 2010;97(2):3.
Abstract: We investigated the homogenous nucleation of crystalline grains in amorphous Si during transient temperature pulse of few milliseconds IR laser irradiation. The crystallized volume fraction is ~80%. Significant crystallization occurs in nonsteady regime because of the rapid temperature variation (106 °C/s). Our model combines the time evolution of the crystal grain population with the consumption of the amorphous volume due to the growth of grains. Thanks to the experimental approach based on a laser source to heat α-Si and the theoretical model we extended the description of the spontaneous crystallization up to 1323 K or 250 K above the temperature investigated by conventional annealing.
|
|
|
Jang YR, Yoo K-H, Park SM. Rapid thermal annealing of ZnO thin films grown at room temperature. J. Vac. Sci. Technol. A. 2010;28(2):4.
Abstract: The authors successfully obtained high quality ZnO thin films by growing them at room temperature (RT) and postannealing by rapid thermal annealing (RTA). The thin films were grown by pulsed laser deposition on Si (100) substrates at RT, and RTA was performed under various temperatures and ambient conditions. Based on the UV emission to visible emission ratio in RT photoluminescence (PL) spectra, the optimum film was obtained at annealing temperature ~700 °C in an ambient of Ar, N2, or O2 at 0.1 Torr, while the optimum annealing temperature was above 1100 °C in the air ambient at atmospheric pressure. The morphology and structure of the films in different RTA conditions were investigated by using field emission scanning electron microscopy and grazing incidence x-ray diffraction, and were discussed in conjunction with the PL data.
|
|
|
Poglitsch A, Waelkens C, Geis N, Feuchtgruber H, Vandenbussche B, Rodriguez L, et al. The Photodetector Array Camera and Spectrometer (PACS) on the Herschel Space Observatory. A&A. 2010;518:12.
Abstract: The Photodetector Array Camera and Spectrometer (PACS) is one of the three science instruments on ESA's far infrared and submillimetre observatory. It employs two Ge:Ga photoconductor arrays (stressed and unstressed) with 16×25 pixels, each, and two filled silicon bolometer arrays with 16×32 and 32×64 pixels, respectively, to perform integral-field spectroscopy and imaging photometry in the 60-210 μm wavelength regime. In photometry mode, it simultaneously images two bands, 60-85 μm or 85-125 μm and 125-210 μm, over a field of view of ~1.75'× 3.5', with close to Nyquist beam sampling in each band. In spectroscopy mode, it images a field of 47â€ × 47â€, resolved into 5×5 pixels, with an instantaneous spectral coverage of ~1500 km s-1 and a spectral resolution of ~175 km s-1. We summarise the design of the instrument, describe observing modes, calibration, and data analysis methods, and present our current assessment of the in-orbit performance of the instrument based on the performance verification tests. PACS is fully operational, and the achieved performance is close to or better than the pre-launch predictions.
|
|