Rath P, Vetter A, Kovalyuk V, Ferrari S, Kahl O, Nebel C, et al. Travelling-wave single-photon detectors integrated with diamond photonic circuits: operation at visible and telecom wavelengths with a timing jitter down to 23 ps. In: Broquin J-E, Conti GN, editors. Integrated Optics: Devices, Mat. Technol. XX. Vol 9750. Spie; 2016. p. 135–42.
Abstract: We report on the design, fabrication and measurement of travelling-wave superconducting nanowire single-photon detectors (SNSPDs) integrated with polycrystalline diamond photonic circuits. We analyze their performance both in the near-infrared wavelength regime around 1600 nm and at 765 nm. Near-IR detection is important for compatibility with the telecommunication infrastructure, while operation in the visible wavelength range is relevant for compatibility with the emission line of silicon vacancy centers in diamond which can be used as efficient single-photon sources. Our detectors feature high critical currents (up to 31 μA) and high performance in terms of efficiency (up to 74% at 765 nm), noise-equivalent power (down to 4.4×10-19 W/Hz1/2 at 765 nm) and timing jitter (down to 23 ps).
|
Dauler E, Kerman A, Robinson B, Yang J, Voronov B, Goltsman G, et al. Photon-number-resolution with sub-30-ps timing using multi-element superconducting nanowire single photon detectors. J Modern Opt. 2009;56(2):364–73.
Abstract: A photon-number-resolving detector based on a four-element superconducting nanowire single photon detector is demonstrated to have sub-30-ps resolution in measuring the arrival time of individual photons. This detector can be used to characterize the photon statistics of non-pulsed light sources and to mitigate dead-time effects in high-speed photon counting applications. Furthermore, a 25% system detection efficiency at 1550 nm was demonstrated, making the detector useful for both low-flux source characterization and high-speed photon-counting and quantum communication applications. The design, fabrication and testing of this detector are described, and a comparison between the measured and theoretical performance is presented.
|
Seki T, Shibata H, Takesue H, Tokura Y, Imoto N. Comparison of timing jitter between NbN superconducting single-photon detector and avalanche photodiode. Phys C. 2010;470(20):1534–7.
Abstract: We report the pulse-to-pulse timing jitter measurement of a niobium nitride (NbN) superconducting single-photon detector (SSPD) and an InGaAs avalanche photodiode (APD) at 1550-nm wavelength. A direct comparison of their timing jitter was performed by using the same experimental configuration to measure both detectors. The measured jitter of the SSPD and the APD are 75 and 84 ps at full-width at half-maximum (FWHM), and 138 and 384 ps at full-width at tenth-maximum (FWTM), respectively. The jitter of the SSPD remains small at FWTM while that of APD is wide. We also estimated the transmission distances and secure key generation rates for fiber-based quantum key distribution (QKD) which uses these detectors. The estimated transmission distances of the APD are 86 km and 107 km with respect to 1 ns and 100 ps time windows, respectively, and those of the SSPD are 125 km and 172 km with respect to 1 ns and 100 ps time windows, respectively. This estimation indicates the SSPDЃfs advantages for QKD compared to the APD.
|
Shcheslavskiy V, Morozov P, Divochiy A, Vakhtomin Y, Smirnov K, Becker W. Ultrafast time measurements by time-correlated single photon counting coupled with superconducting single photon detector. Rev. Sci. Instrum.. 2016;87:053117 (1 to 5).
Abstract: Time resolution is one of the main characteristics of the single photon detectors besides quantum efficiency and dark count rate. We demonstrate here an ultrafast time-correlated single photon counting (TCSPC) setup consisting of a newly developed single photon counting board SPC-150NX and a superconducting NbN single photon detector with a sensitive area of 7 × 7 μm. The combination delivers a record instrument response function with a full width at half maximum of 17.8 ps and system quantum efficiency ~5% at wavelength of 1560 nm. A calculation of the root mean square value of the timing jitter for channels with counts more than 1% of the peak value yielded about 7.6 ps. The setup has also good timing stability of the detector–TCSPC board.
|
Shcheslavskiy V, Morozov P, Divochiy A, Vakhtomin Y, Smirnov K, Becker W. Erratum: “Ultrafast time measurements by time-correlated single photon counting coupled with superconducting single photon detector” [Rev. Sci. Instrum. 87, 053117 (2016)]. Vol 87.; 2016.
Abstract: In the original paper1the Ref. 10 should be M. Sanzaro, N. Calandri, A. Ruggeri, C. Scarcella, G. Boso, M. Buttafava, and A. Tosi, Proc. SPIE9370, 93701T (2015).
|