Gross R, Marx A. Applied superconductivity: Josephson effect and superconducting electronics. Chapter 7. In: Walther-Meißner-Institut.; 2005.
|
Encrenaz T. Neutral Atmospheres of the Giant Planets: An Overview of Composition Measurements. Space Sci Rev. 2005;116(1-2):99–119.
|
Morozov DV, Smirnov KV, Smirnov AV, Lyakhov VA, Goltsman GN. A millimeter-submillimeter phonon-cooled hot-electron bolometer mixer based on two-dimensional electron gas in an AlGaAs/GaAs heterostructure. Semicond. 2005;39(9):1082–6.
Abstract: Experimental results obtained by studying the main characteristics of a millimeter-submillimeter wave mixer based on the hot-electron effect in a two-dimensional electron gas in a AlGaAs/GaAs heterostructure with a phonon-scattering cooling mechanism for charge carriers are reported. The gain bandwidth of the mixer is 4 GHz, the internal conversion losses are 13 dB, and the optimum local-oscillator power is 0.5 μW (for a mixer area of 1 μm2). It is shown that a millimeter-submillimeter-wave receiver with a noise temperature of 1900 K can be developed on the basis of a AlGaAs/GaAs mixer. This mixer also appears to be promising for use in array receiver elements.
|
Tol J van, Brunel L-C, Wylde RJ. A quasioptical transient electron spin resonance spectrometer operating at 120 and 240 GHz. Rev Sci Instrum. 2005;76(7):074101 (1 to 8).
Abstract: A new multifrequency quasioptical electron paramagnetic resonance (EPR) spectrometer is described. The superheterodyne design with Schottky diode mixer/detectors enables fast detection with subnanosecond time resolution. Optical access makes it suitable for transient EPR (TR-EPR) at 120 and 240 GHz. These high frequencies allow for an accurate determination of small g-tensor anisotropies as are encountered in excited triplet states of organic molecules like porphyrins and fullerenes. The measured concentration sensitivity for continuous-wave (cw) EPR at 240 GHz and at room temperature without cavity is 1013 spins/cm3 (15 nM) for a 1 mT linewidth and a 1 Hz bandwidth. With a Fabry-Perot cavity and a sample volume of 30 nl, the sensitivity at 240 GHz corresponds to [approximate]3×109 spins for a 1 mT linewidth. The spectrometer's performance is illustrated with applications of transient EPR of excited triplet states of organic molecules, as well as cw EPR of nitroxide reference systems and a thin film of a colossal magnetoresistance material.
|
Finkel MI, Maslennikov SN, Gol'tsman GN. Terahertz heterodyne receivers based on superconductive hot-electron bolometer mixers. Radiophys Quant Electron. 2005;48(10-11):859–64.
Abstract: We consider recent results in development of hot-electron bolometer mixers. Special attention is paid to optimization of the contacts between the antenna and the active area of a superconducting film. An important result in the study of the parasitic effect of direct detection is obtained during the measurement of the noise temperatures by the hot/cold load method. The latest results of studies of the waveguide hot-electron bolometer mixers and their successful practical applications are considered. Progress in development of high-frequency (over 1.3 THz) heterodyne receivers for several important international projects is discussed and new submillimeter radio astronomy projects ESPRIT and SAFIR are described.
|