|
Gershenzon EM, Gol'tsman GN, Emtsev VV, Mashovets TV, Ptitsyna NG, Ryvkin SM. Role of impurities of groups III and V in the formation of defects following γ irradiation of germanium. JETP Lett. 1971;14(6):241.
|
|
|
Zhang J, Slysz W, Verevkin A, Okunev O, Chulkova G, Korneev A, et al. Response time characterization of NbN superconducting single-photon detectors. IEEE Trans. Appl. Supercond.. 2003;13(2):180–3.
Abstract: We report our time-resolved measurements of NbN-based superconducting single-photon detectors. The structures are meander-type, 10-nm thick, and 200-nm wide stripes and were operated at 4.2 K. We have shown that the NbN devices can count single-photon pulses with below 100-ps time resolution. The response signal pulse width was about 150 ps, and the system jitter was measured to be 35 ps.
|
|
|
Cherednichenko S, Khosropanah P, Adam A, Merkel HF, Kollberg EL, Loudkov D, et al. 1.4- to 1.7-THz NbN hot-electron bolometer mixer for the Herschel space observatory. In: Phillips TG, Zmuidzinas J, editors. Proc. SPIE. Vol 4855. SPIE; 2003. p. 361–70.
Abstract: NbN hot- electron bolometer mixers have reached the level of 10hv/k in terms of the input noise temperature with the noise bandwidth of 4-6 GHz from subMM band up to 2.5 THz. In this paper we discuss the major characteristics of this kind of receiver, i.e. the gain and the noise bandwidth, the noise temperature in a wide RF band, bias regimes and optimisation of RF coupling to the quasioptical mixer. We present the status of the development of the mixer for Band 6 Low for Herschel Telescope.
|
|
|
Danerud M, Winkler D, Zorin M, Trifonov V, Karasik B, Gershenzon EM, et al. Picosecond detection of infrared radiation with YBa2Cu3O7-δ thin films. In: Birch JR, Parker TJ, editors. Proc. SPIE. Vol 2104. Spie; 1993. p. 183–4.
Abstract: Picosecond nonequilibrium and slow bolometric responses from a patterned high-Tc superconducting (HTS) film due toinfrared radiation were investigated using both modulation and pulse techniques. Measurements at A, = 0.85 [tm andA, = 10.6 lim have shown a similar behaviour of the response vs modulation frequency f. The responsivity of the HTS filmbased detector at f ..- 0.6-1 GHz is estimated to be 10-2 – 10-1 V/W.
|
|
|
Gershenzon EM, Gol'tsman GN. Hot-electron superconducting mixers. In: Birch JR, Parker TJ, editors. Proc. SPIE. Vol 2104. SPIE; 1993. p. 329–30.
Abstract: The creation of low noise heterodyne receivers for frequencies above 1 THz is in the urgentneed for radio astronomy, laser spectroscopy, plasma diagnostic, etc. In this paper we discussthe nonlinear effect related to hot electrons in superconductors, and their potential use in lownoise submilimeter wave mixer. We also discuss results achieved so far as well as possible futuredevelopments.
|
|