|
Cherednichenko S, Drakinskiy V, Berg T, Kollberg EL, Angelov I. The direct detection effect in the hot-electron bolometer mixer sensitivity calibration. IEEE Trans. Microw. Theory Techn.. 2007;55(3):504–10.
|
|
|
Burke PJ, Schoelkopf RJ, Prober DE, Skalare A, Karasik BS, Gaidis MC, et al. Mixing and noise in diffusion and phonon cooled superconducting hot-electron bolometers. J. Appl. Phys.. 1999;85(3):1644–53.
|
|
|
Gao JR, Hajenius M, Yang ZQ, Baselmans JJA, Khosropanah P, Barends R, et al. Terahertz superconducting hot electron bolometer heterodyne receivers. IEEE Trans. Appl. Supercond.. 2007;17(2):252–8.
Abstract: We highlight the progress on NbN hot electron bolometer (HEB) mixers achieved through fruitful collaboration between SRON Netherlands Institute for Space Research and Delft University of Technology, the Netherlands. This includes the best receiver noise temperatures of 700 K at 1.63 THz using a twin-slot antenna mixer and 1050 K at 2.84 THz using a spiral antenna coupled HEB mixer. The mixers are based on thin NbN films on Si and fabricated with a new contact-process and-structure. By reducing their areas HEB mixers have shown an LO power requirement as low as 30 nW. Those small HEB mixers have demonstrated equivalent sensitivity as those with large areas provided the direct detection effect due to broadband radiation is removed. To manifest that a HEB based heterodyne receiver can in practice be used at arbitrary frequencies above 2 THz, we demonstrate a 2.8 THz receiver using a THz quantum cascade laser (QCL) as local oscillator.
|
|
|
Ryabchun S, Tong C-YE, Blundell R, Gol'tsman G. Stabilization scheme for hot-electron bolometer receivers using microwave radiation. IEEE Trans Appl Supercond. 2009;19(1):14–9.
Abstract: We present the results of a stabilization scheme for terahertz receivers based on NbN hot-electron bolometer (HEB) mixers that uses microwave radiation with a frequency much lower than the gap frequency of NbN to compensate for mixer current fluctuations. A feedback control loop, which actively controls the power level of the injected microwave radiation, has successfully been implemented to stabilize the operating point of the HEB mixer. This allows us to increase the receiver Allan time to 10 s and also improve the temperature resolution of the receiver by about 30% in the total power mode of operation.
|
|
|
Cherednichenko S, Drakinskiy V, Baubert J, Krieg J-M, Voronov B, Gol'tsman G, et al. Gain bandwidth of NbN hot-electron bolometer terahertz mixers on 1.5 μm Si3N4 / SiO2 membranes. J Appl Phys. 2007;101(12):124508 (1 to 6).
Abstract: The gain bandwidth of NbN hot-electron bolometer terahertz mixers on electrically thin Si3N4/SiO2 membranes was experimentally investigated and compared with that of HEB mixers on bulk substrates. A gain bandwidth of 3.5 GHz is achieved on bulk silicon, whereas the gain bandwidth is reduced down to 0.6–0.9 GHz for mixers on 1.5 μm Si3N4/SiO2 membranes. We show that application of a MgO buffer layer on the membrane extends the gain bandwidth to 3 GHz. The experimental data were analyzed using the film-substrate acoustic mismatch approach.
|
|