Meledin D., Desmaris V., Ferm S.-E., Fredrixon M., Henke D., Lapkin I., et al. APEX Band T2: A 1.25 – 1.39 THz Waveguide Balanced HEB Receiver.. 2008:181–5.
Abstract: A waveguide 1.25–1.39 THz Hot Electron Bolometer (HEB) balanced receiver was successfully developed, characterized and installed at the Atacama Pathfinder EXperiment (APEX) telescope. The receiver employs a quadrature balanced scheme using a waveguide 90-degree 3 dB RF hybrid, HEB mixers and a 180-degree IF hybrid. The HEB mixers are based on ultrathin NbN film deposited on crystalline quartz with a MgO buffer layer. Integrated into the multi-channel APEX facility receiver (SHeFI), the results presented here demonstrate exceptional performance; a receiver noise temperature of 1000 K measured at the telescope at the center of the receiver IF band 2-4 GHz, and at an LO frequency of 1294 GHz. Stability of the receiver is fully in line with the SIS mixer bands of the SHeFI, and gives a spectroscopic Allan time of more than 200 s with a noise bandwidth of 1 MHz.
|
Semenov A, Hübers H-W, Engel A, Gol'tsman GN. Background limited superconducting quantum detector for astronomy [abstract]. In: NASA/ADS.; 2002.
Abstract: We present the concept of the superconducting quantum detector for astronomy. Response to a single absorbed photon appears due to successive formation of a normal spot and phase-slip-centers in a narrow strip carrying sub-critical supercurrent. The detector simultaneously has a moderate energy resolution and a variable cut-off wavelength depending on both the material used and operation conditions. We simulated performance of the background-limited direct detector having the 100- micrometer cut-off wavelength. Low dark count rate will allow to realize 10-21 W Hz-1/2 noise equivalent power at 4 K background radiation. The intrinsic recovery time of the counter is rather determined by diffusion of nonequilibrium electrons, thus, thermal fluctuations do not hamper energy resolution of the detector. Provided an appropriate readout technique, the resolution should be better than 1/20 at 50- micrometer wavelength. Planar layout and relatively simple technology favor integration of the detector into an array.
|
Schubert J, Semenov A, Hübers H-W, Gol'tsman G, Schwaab G, Voronov B, et al. Broad-band terahertz NbN hot-electron bolometric mixer. In: Inst. Phys. Conf. Vol 167.; 1999. p. 663–6.
|
Gershenzon EM, Il'in VA, Litvak-Gorskaya LB, Filonovich SR. Character of submillimeter photoconductivity in n-lnSb. Sov Phys JETP. 1979;49(1):121–8.
Abstract: A comprehensive investigation was made of the submillimeter photoconductivity of n -1nSb in the range of wavelengths L = 0.6-8 mm, magnetic fields H = 0-30 kOe, electric fields E = 0.01-0.5 V/cm, and temperatures T = 1.3-30 K. The kinetics of the photoconductivity processes as a function of T, E; and H is investigated. It is shown that impurity photoconductivity does exist for any degree of compensation of extremely purified n-InSb. Particular attention is paid to the hopping photoconductivity realized in strongly compensated n-1nSb (K > 0.8).
|
Jiang L, Miao W, Zhang W, Li N, Lin ZH, Yao QJ, et al. Characterization of a quasi-optical NbN superconducting HEB mixer. IEEE Trans Microwave Theory Techn. 2006;54(7):2944–8.
Abstract: In this paper, the performance of a quasi-optical NbN superconducting hot-electron bolometer (HEB) mixer, cryogenically cooled by a close-cycled 4-K refrigerator, is thoroughly investigated at 300, 500, and 850 GHz. The lowest receiver noise temperatures measured at the respective three frequencies are 1400, 900, and 1350 K, which can go down to 659, 413, and 529 K, respectively, after correcting the loss and associated noise contribution of the quasi-optical system before the measured superconducting HEB mixer. The stability of the quasi-optical superconducting HEB mixer is also investigated here. The Allan variance time measured with a local oscillator pumping at 500 GHz and an IF bandwidth of 110 MHz is 1.5 s at the dc-bias voltage exhibiting the lowest noise temperature and increases to 2.5 s at a dc bias twice that voltage.
|