Nebosis RS, Heusinger MA, Semenov AD, Lang PT, Schatz W, Steinke R, et al. Ultrafast photoresponse of an YBa2Cu3O7-δ film to far-infrared radiation pulses. Opt Lett. 1993;18(2):96–7.
Abstract: We report the observation of an ultrafast photoresponse of a high-T(c), film to far-infrared radiation pulses. The response of a sample, consisting of a current-carrying structured YBa(2)Cu(3)O(7-delta) film cooled to liquid-nitrogen temperature, was studied by use of ultrashort laser pulses from an optically pumped far-infrared laser in the frequency range from 0.7 to 7 THz. We found that the response time was limited by the time resolution, 120 ps, of our electronic registration equipment.
|
Semenov AD, Gol’tsman GN, Gogidze IG, Sergeev AV, Gershenzon EM, Lang PT, et al. Subnanosecond photoresponse of a YBaCuO thin film to infrared and visible radiation by quasiparticle induced suppression of superconductivity. Appl Phys Lett. 1992;60(7):903–5.
Abstract: We observed subnanosecond photoresponse of a structured superconducting YBa2Cu3O7−δ thin film to infrared and visible radiation. We measured the voltage response of a current biased film (thickness 700 Å) in a resistive state to radiation pulses. From our results we conclude a response time of about 90 ps and a responsivity of about 4×1010 Ω/J. We attribute the response to Cooper pair breaking and suppression of the superconducting energy gap induced by nonequilibrium quasiparticles.
|
Gol'tsman GN, Semenov AD, Gousev YP, Zorin MA, Gogidze IG, Gershenzon EM, et al. Sensitive picosecond NbN detector for radiation from millimetre wavelengths to visible light. Supercond Sci Technol. 1991;4(9):453–6.
Abstract: The authors report on the application of a broad-band NbN film detector which has high sensitivity and picosecond response time for detection of radiation from millimetre wavelengths to visible light. From a study of amplitude modulated radiation of backward-wave tubes and picosecond pulses from gas and solid state lasers at wavelengths between 2 mm and 0.53 mu m, they found a detectivity of 1010 W-1 cm Hz-1/2 and a response time of less than 50 ps at T=10 K. The characteristics were provided by using a 150 AA thick NbN film patterned into a structure of micron strips. According to the proposed detection mechanism, namely electron heating, they expect an intrinsic response time of approximately 20 ps at the same temperature.
|
Nebosis RS, Steinke R, Lang PT, Schatz W, Heusinger MA, Renk KF, et al. Picosecond YBa2Cu3O7−δdetector for far‐infrared radiation. J Appl Phys. 1992;72(11):5496–9.
Abstract: We report on a picosecond YBa2Cu3O7−δ detector for far‐infrared radiation. The detector, consisting of a current carrying structure cooled to liquid‐nitrogen temperature, was studied by use of ultrashort laser pulses from an optically pumped far‐infrared laser in the frequency range from 25 to 215 cm−1. We found that the sensitivity (1 mV/W) was almost constant in this frequency range. We estimated a noise equivalent power of less than 5×10−7 W Hz−1/2. Taking into account the results of a mixing experiment (in the frequency range from 4 to 30 cm−1) we suggest that the response time of the detector was few picoseconds.
|
Lang PT, Leipold I, Knott WJ, Semenov AD, Gol'tsman GN, Renk KF. New far-infrared laser lines from CH3Cl and CH3Br optically pumped with a continuously tunable high pressure CO2 laser. Appl Phys B. 1991;53(4):207–12.
Abstract: In this paper we report on the detection of new far-infrared laser lines from CH3Cl and CH3Br optically pumped with a continuously tunable high pressure CO2 laser. We found 80 new lines for CH3Cl and 9 new lines for CH3Br in the frequency region between 16 cm−1 and 41 cm−1, all due to stimulated Raman scattering. For the Raman gain regions bandwidths up to about 700 MHz were found. We also observed high intensity short far-infrared laser pulses of durations in the nanosecond regime.
|