Baselmans JJA, Hajenius M, Gao JR, Baryshev A, Kooi J, Klapwijk TM, et al. NbN hot electron bolometer mixers: sensitivity, LO power, direct detection and stability. IEEE Trans Appl Supercond. 2005;15(2):484–9.
Abstract: We demonstrate that the performance of NbN lattice cooled hot electron bolometer mixers depends strongly on the interface quality between the bolometer and the contact structure. Both the receiver noise temperature and the gain bandwidth can be improved by a factor of 2 by cleaning the interface and adding an additional superconducting interlayer to the contact pad. Using this we obtain a double sideband receiver noise temperature of 950 K at 2.5 THz and 4.3 K, using a 0.4/spl times/4 /spl mu/m HEB mixer with a spiral antenna. At the same bias point, we obtain an IF gain bandwidth of 6 GHz. To comply with current demands on THz mixers for use in space based receivers we reduce the device size to 0.15/spl times/1 /spl mu/m and use a twin slot antenna. We report measurements of the noise temperature, LO power requirement, stability and the direct detection effect, using a mixer with a 1.6 THz twin slot antenna and a 1.462 THz solid state LO source with calibrated output power.
|
Dauler EA, Robinson BS, Kerman AJ, Yang JKW, Rosfjord EKM, Anant V, et al. Multi-element superconducting nanowire single-photon detector. IEEE Trans Appl Supercond. 2007;17(2):279–84.
Abstract: A multi-element superconducting nanowire single photon detector (MESNSPD) is presented that consists of multiple independently-biased superconducting nanowire single photon detector (SNSPD) elements that form a continuous active area. A two-element SNSPD has been fabricated and tested, showing no measurable crosstalk between the elements, sub-50-ps relative timing jitter, and four times the maximum counting rate of a single SNSPD with the same active area. The MESNSPD can have a larger active area and higher speed than a single-element SNSPD and the input optics can be designed so that the detector provides spatial, spectral or photon number resolution.
|
Gol'tsman G, Minaeva O, Korneev A, Tarkhov M, Rubtsova I, Divochiy A, et al. Middle-infrared to visible-light ultrafast superconducting single-photon detectors. IEEE Trans Appl Supercond. 2007;17(2):246–51.
Abstract: We present an overview of the state-of-the-art of NbN superconducting single-photon detectors (SSPDs). Our devices exhibit quantum efficiency (QE) of up to 30% in near-infrared wavelength and 0.4% at 5 mum, with a dark-count rate that can be as low as 10 -4 s -1 . The SSPD structures integrated with lambda/4 microcavities achieve a QE of 60% at telecommunication, 1550-nm wavelength. We have also developed a new generation of SSPDs that possess the QE of large-active-area devices, but, simultaneously, are characterized by low kinetic inductance that allows achieving short response times and the GHz-counting rate with picosecond timing jitter. The improvements presented in the SSPD development, such as fiber-coupled SSPDs, make our detectors most attractive for high-speed quantum communications and quantum computing.
|
Shurakov A, Tong C-YE, Blundell R, Kaurova N, Voronov B, Gol'tsman G. Microwave stabilization of a HEB mixer in a pulse-tube cryocooler. IEEE Trans Appl Supercond. 2013;23(3):1501504.
Abstract: We report the results of our study of the stability of an 800 GHz hot electron bolometer (HEB) mixer cooled with a pulse-tube cryocooler. Pulse-tube cryocoolers introduce temperature fluctuations as well as mechanical vibrations at a frequency of ~1 Hz, both of which can cause receiver gain fluctuations at that frequency. In our system, the motor of the cryocooler was separated from the cryostat to minimize mechanical vibrations, leaving thermal effects as the dominant source of the receiver gain fluctuations. We measured root mean square temperature variations of the 4 K stage of ~7 mK. The HEB mixer was pumped by a solid state local oscillator at 810 GHz. The root mean square current fluctuations at the low noise operating point (1.50 mV, 56.5 μA) were ~0.12 μA, and were predominantly due to thermal fluctuations. To stabilize the bias current, microwave radiation was injected to the HEB mixer. The injected power level was set by a proportional-integral-derivative controller, which completely compensates for the bias current oscillations induced by the pulse-tube cryocooler. Significant improvement in the Allan variance of the receiver output power was obtained, and an Allan time of 5 s was measured.
|
Zhang W, Miao W, Li SL, Zhou KM, Shi SC, Gao JR, et al. Measurement of the spectral response of spiral-antenna coupled superconducting hot electron bolometers. IEEE Trans Appl Supercond. 2013;23(3):2300804.
Abstract: Measured spectral response of spiral-antenna coupled superconducting hot electron bolometers (HEBs) often drops dramatically at frequencies that are still within the frequency range of interest (e.g., ~ 5 THz). This is inconsistent with the implied low receiver noise temperatures from the same measurements. To understand this discrepancy, we exhaustively test and calibrate the thermal sources used in Fourier transform spectrometer measurements. We first investigate the absolute emission spectrum of high-pressure Hg arc lamp, then measure the spectral response of two spiral-antenna coupled NbN HEBs with a Martin-Puplett interferometer as spectrometer and 77 K blackbody as broadband signal source. The measured absolute emission spectrum of Hg arc lamp is proportional to frequency, corresponding to an equivalent blackbody temperature of 4000 K at 1 THz, 1500 K at 3 THz, and 800 K at 5 THz, respectively. Measured spectral response of spiral-antenna coupled NbN HEBs, corrected for air absorption, is nearly flat in the frequency range of 0.5-4 THz, consistent with simulated coupling efficiency between HEB and spiral-antenna. These results explain the discrepancy, and prove that spiral-antenna coupled superconducting NbN HEBs work well in a wide frequency range. In addition, this calibration method and these results are broadly applicable to other quasi-optical THz receivers.
|