Kovalyuk V, Ferrari S, Kahl O, Semenov A, Lobanov Y, Shcherbatenko M, et al. Waveguide integrated superconducting single-photon detector for on-chip quantum and spectral photonic application.; 2017.
Abstract: By adopting a travelling-wave geometry approach, integrated superconductor- nanophotonic devices were fabricated. The architecture consists of a superconducting NbN- nanowire atop of a silicon nitride (Si 3 N 4 ) nanophotonic waveguide. NbN-nanowire was operated as a single-photon counting detector, with up to 92% on-chip detection efficiency (OCDE), in the coherent mode, serving as a highly sensitive IR heterodyne mixer with spectral resolution (f/df) greater than 10^6 in C-band at 1550 nm wavelength.
|
|
|
Tarkhov M, Claudon J, Poizat JP, Korneev A, Divochiy A, Minaeva O, et al. Ultrafast reset time of superconducting single photon detectors. Appl Phys Lett. 2008;92(24):241112 (1 to 3).
|
|
|
Semenov A, Haas P, Ilin K, Hubers H, Siegel M, Engel A, et al. Energy resolution and sensitivity of a superconducting quantum detector. Phys C: Supercond. 2007;460-462:1491–2.
|
|
|
Gershenzon EM, Goltsman GN, Semenov AD, Sergeev AV. Limiting characteristic of fast superconducting bolometers. Sov Phys-Tech Phys. 1989;34:195–9.
Abstract: Теоретически и экспериментально исследовано физическое ограничение быстродействия сверхпроводящего болометра. Показано, что минимальная постоянная времени реализуется в условиях электронного разогрева и определяется процессом неупругого электрон-фонон- ного взаимодействия. Сформулированы требования кконструкции «электронного болометра» для достижения предельной чувствительности. Проведено сравнение характеристик электронного болометра и обычных болометров различных типов.
|
|
|
Gershenzon EM, Gershenzon ME, Goltsman GN, Semenov AD, Sergeev AV. Wide-band highspeed Nb and YBaCuO detectors. IEEE Trans Magn. 1991;27(2):2836–9.
Abstract: The physical limitations on the response time and the nature of nonequilibrium detection of radiation were investigated for Nb and YBCO film in a wide spectral range from millimeter to near-infrared wavelengths. In the case of ideal heat removal from the film, the detection mechanism is connected with an electron heating effect which is not selective over a wide spectral interval. For Nb, the dependence of the response time on the electron mean free path l and temperature T is tau varies as T/sup -2/l/sup -1/. The values of detectivity D* and tau are 3*10/sup 11/ W/sup -1/ Hz/sup 1/2/ cm and 5*10/sup -9/ s at T=1.6 K, respectively. For YBCO film the tau value of 1-2 ps at T=77 K was obtained; the NEP value of 3*10/sup -11/ W-Hz/sup -1/2/ can be obtained at T=77 K in the case of the optimal film matching to the radiation.
|
|