|
Zolotov P, Vakhtomin Y, Divochiy A, Morozov P, Seleznev V, Smirnov K. Development of fast and high-effective single-photon detector for spectrum range up to 2.3 μm. In: Proc. SPBOPEN.; 2017. p. 439–40.
Abstract: We present the results of development and testing of the single-photon-counting system operating in the wide spectrum rane up to 2.3 mcm. We managed to increase system detection efficiency up to 60% in the range of 1.7-2.3 mcm optimisation of the fabrication methods of superconducting single-photon detectors and application of the single-mode fiber with enlarged core diameter.
|
|
|
Simonov NO, Korneeva YP, Korneev AA, Goltsman GN. Enhance of the superconducting properties of the NbN/Au bilayer bridges. In: J. Phys.: Conf. Ser. Vol 1695.; 2020. 012132 (1 to 4).
Abstract: We experimentally demonstrate strong temperature dependence of the critical current of the superconducting 600-nm-wide and 5-μm-long bridge made of NbN/Au bilayer. The result is achieved due to the proximity effect realized between the highly disordered superconducting NbN layer and low resistive normal-metal Au layer.
|
|
|
Elezov MS, Shcherbatenko ML, Sych DV, Goltsman GN. Development of control method for an optimal quantum receiver. In: J. Phys.: Conf. Ser. Vol 1695.; 2020. 012126.
Abstract: We propose a method for optimal displacement controlling of an optimal quantum receiver for registrations a binary coherent signal. An optimal receiver is able to distinguish between two phase-modulated states of a coherent signal. The optimal receiver controlling method can be used later in practice in various physical implementations of the optimal receiver.
|
|
|
Manova NN, Smirnov EO, Korneeva YP, Korneev AA, Goltsman GN. Superconducting photon counter for nanophotonics applications. In: J. Phys.: Conf. Ser. Vol 1410.; 2019. 012147 (1 to 5).
Abstract: We develop large area superconducting single-photon detector SSPD with a micron-wide strip suitable for free-space coupling or packaging with multi-mode optical fibres. The detector sensitive area is 20 μm in diameter. In near infrared (1330 nm wavelength) our SSPD exhibits above 30% detection efficiency with low dark counts and 45 ps timing jitter.
|
|
|
Polyakova MI, Florya IN, Semenov AV, Korneev AA, Goltsman GN. Extracting hot-spot correlation length from SNSPD tomography data. In: J. Phys.: Conf. Ser. Vol 1410.; 2019. 012166 (1 to 4).
Abstract: We present data of quantum detector tomography for the samples specifically optimized for this problem. Using this method, we take results of hot-spot correlation length of 17 ± 2 nm.
|
|