Huebers H-W, Schubert J, Semenov A, Gol’tsman GN, Voronov BM, Gershenzon EM, et al. NbN phonon-cooled hot-electron bolometer as a mixer for THz heterodyne receivers. In: Chamberlain JM, editor. Proc. SPIE. Vol 3828. Spie; 1999. p. 410–6.
Abstract: We have investigated a phonon-cooled NbN hot electron bolometric (HEB) mixer in the frequency range from 0.7 THz to 5.2 THz. The device was a 3.5 nm thin film with an in- plane dimension of 1.7 X 0.2 micrometers 2 integrated in a complementary logarithmic spiral antenna. The measured DSB receiver noise temperatures are 1500 K, 2200 K, 2600 K, 2900 K, 4000 K, 5600 K and 8800 K. The sensitivity fluctuation, the long term stability, and the antenna pattern were measured and the suitability of the mixer for a practical heterodyne receiver is discussed.
|
Leisawitz DT, Danchi WC, Dipirro MJ, Feinberg LD, Gezari DY, Hagopian M, et al. Scientific motivation and technology requirements for the SPIRIT and SPECS far-infrared/submillimeter space interferometers. In: Proc. SPIE. Vol 4013.; 2000. p. 36–46.
Abstract: Far infrared interferometers in space would enable extraordinary measurements of the early universe, the formation of galaxies, stars, and planets, and would have great discovery potential. Since half the luminosity of the universe and 98% of the photons released since the Big Bang are now observable at far IR wavelengths (40 – 500 micrometers ), and the Earth's atmosphere prevents sensitive observations from the ground, this is one of the last unexplored frontiers of space astronomy. We present the engineering and technology requirements that stem from a set of compelling scientific goals and discuss possible configurations for two proposed NASA missions, the Space Infrared Interferometric Telescope and the Submillimeter Probe of the Evolution of Cosmic Structure.
|
Huebers H-W, Semenov A, Schubert J, Gol’tsman GN, Voronov BM, Gershenzon EM, et al. NbN hot-electron bolometer as THz mixer for SOFIA. In: Melugin RK, Roeser H-P, editors. Proc. SPIE. Vol 4014. SPIE; 2000. p. 195–202.
Abstract: Heterodyne receivers for applications in astronomy need quantum limited sensitivity. We have investigated phonon- cooled NbN hot electron bolometric mixers in the frequency range from 0.7 THz to 5.2 THz. The devices were 3.5 nm thin films with an in-plane dimension of 1.7 X 0.2 micrometers 2 integrated in a complementary logarithmic spiral antenna. The best measured DSB receiver noise temperatures are 1300 K (0.7 THz), 2000 K (1.4 THz), 2100 K (1.6 THz), 2600 K (2.5 THz), 4000 K (3.1 THz), 5600 K (4.3 THz), and 8800 K (5.2 THz). The sensitivity fluctuation, the long term stability, and the antenna pattern were measured. The results demonstrate that this mixer is very well suited for GREAT, the German heterodyne receiver for SOFIA.
|
Puscasu I, Boreman GD. Theoretical and experimental analysis of transmission and enchanced absorption of frequency selective surfaces in the infrared. In: Proc. SPIE. Vol 4293.; 2001. p. 185–90.
Abstract: A comparative study between theory and experiment is presented for transmission through lossy frequency selective surfaces (FSSs) on silicon in the 2 – 15 micrometer range. Important parameters controlling the resonance shape and location are identified: dipole length, spacing, impedance, and dielectric surroundings. Their separate influence is exhibited. The primary resonance mechanism of FSSs is the resonance of the individual metallic patches. There is no discernable resonance arising from a feed-coupled configuration. The real part of the element's impedance controls the minimum value of transmission, while scarcely affecting its location. Varying the imaginary part shifts the location of resonance, while only slightly changing the minimum value of transmission. With such fine-tuning, it is possible to make a good fit between theory and experiment near the dipole resonance on any sample. A fixed choice of impedance can provide a reasonable fit to all samples fabricated under the same conditions. The dielectric surroundings change the resonance wavelength of the FSS compared to its value in air. The presence of FSS on the substrate increases the absorptivity/emissivity of the surface in a resonant way. Such enhancement is shown for dipole and cross arrays at several wavelengths.
|
Boreman GD. A Users guide to IR detectors. In: Proc. SPIE. Vol 4420.; 2001. p. 79–90.
Abstract: This paper will guide the first-time user toward proper selection and use of IR detectors for applications in industrial inspection, process control, and laser measurements.
|