|
Heusinger MA, Nebosis RS, Schatz W, Renk KF, Gol’tsman GN, Karasik BS, et al. Temperature dependence of bolometric and non-bolometric photoresponse of a structured YBa2Cu3O7-δ thin film. In: Meissner M, Pohl RO, editors. Phonon Scattering in Condensed Matter VII. Springer Series in Solid-State Sciences. Vol 112.; 1993. p. 193–5.
Abstract: We investigated the temperature dependence of the transient voltage photoresponse of a current biased structured YBa2Cu3O7−δ thin film in its transition temperature region, around 79 K. Both, picosecond nonbolometric and nanosecond bolometric response to ultrashort far-infrared laser pulses were found for frequencies between 25 cm−1 and 215 cm−1. We will discuss optimum conditions for radiation detection and present an analysis of the dynamical behaviour of excited high T c thin films.
|
|
|
Bespalov AV, Gol'tsman GN, Semenov AD, Renk KF. Determination of the far-infrared emission characteristic of a cyclotron p-germanium laser by use of a superconducting Nb detector. Solid State Communications. 1991;80(7):503–6.
Abstract: We studied the far-infrared emission characteristics of a cyclotron p-germanium laser using a broad-band superconducting Nb film detector. For magnetic fields between ∼25 kOe and ∼50 kOe, emission in a frequency range from ∼50 cm-1 to ∼100 cm-1 with maximum intensity around 90 cm-1 was obtained. We determined, for fixed magnetic fields, electric field dependences of the emission intensity taking into account that the total electric field is a sum of the applied and the Hall electric field. An analysis of the emission intensity characteristic gives evidence that transitions between the two lowest Landau levels of light holes are responsible for the laser action.
|
|
|
Gousev YP, Gol'tsman GN, Semenov AD, Gershenzon EM, Nebosis RS, Heusinger MA, et al. Broadband ultrafast superconducting NbN detector for electromagnetic radiation. J Appl Phys. 1994;75(7):3695–7.
Abstract: An ultrafast detector that is sensitive to radiation in a broad spectral range from submillimeter waves to visible light is reported. It consists of a structured NbN thin film cooled to a temperature below Tc (∼11 K). Using 20 ps pulses of a GaAs laser, we observed signal pulses with both rise and decay time of about 50 ps. From the analysis of a mixing experiment with submillimeter radiation we estimate an intrinsic response time of the detector of ∼12 ps. The sensitivity was found to be similar for the near‐infrared and submillimeter radiation. Broadband sensitivity and short response time are attributed to a quasiparticle heating effect.
|
|
|
Nebosis RS, Steinke R, Lang PT, Schatz W, Heusinger MA, Renk KF, et al. Picosecond YBa2Cu3O7−δdetector for far‐infrared radiation. J Appl Phys. 1992;72(11):5496–9.
Abstract: We report on a picosecond YBa2Cu3O7−δ detector for far‐infrared radiation. The detector, consisting of a current carrying structure cooled to liquid‐nitrogen temperature, was studied by use of ultrashort laser pulses from an optically pumped far‐infrared laser in the frequency range from 25 to 215 cm−1. We found that the sensitivity (1 mV/W) was almost constant in this frequency range. We estimated a noise equivalent power of less than 5×10−7 W Hz−1/2. Taking into account the results of a mixing experiment (in the frequency range from 4 to 30 cm−1) we suggest that the response time of the detector was few picoseconds.
|
|
|
Semenov AD, Gousev YP, Nebosis RS, Renk KF, Yagoubov P, Voronov BM, et al. Heterodyne detection of THz radiation with a superconducting hot‐electron bolometer mixer. Appl Phys Lett. 1996;69(2):260–2.
Abstract: We report on the use of a superconducting hot‐electron bolometer mixer for heterodyne detection of terahertz radiation. Radiation with a wavelength of 119 μm was coupled to the mixer, a NbN microbridge, by a hybrid quasioptical antenna consisting of an extended hyperhemispherical lens and a planar logarithmic spiral antenna. We found, at an intermediate frequency of 1.5 GHz, a system double side band noise temperature of ≊40 000 K and conversion losses of 25 dB. We also discuss the possibilities of further improvement of the mixer performance.
|
|