|
Gol'tsman GN, Semenov AD, Gousev YP, Zorin MA, Gogidze IG, Gershenzon EM, et al. Sensitive picosecond NbN detector for radiation from millimetre wavelengths to visible light. Supercond Sci Technol. 1991;4(9):453–6.
Abstract: The authors report on the application of a broad-band NbN film detector which has high sensitivity and picosecond response time for detection of radiation from millimetre wavelengths to visible light. From a study of amplitude modulated radiation of backward-wave tubes and picosecond pulses from gas and solid state lasers at wavelengths between 2 mm and 0.53 mu m, they found a detectivity of 1010 W-1 cm Hz-1/2 and a response time of less than 50 ps at T=10 K. The characteristics were provided by using a 150 AA thick NbN film patterned into a structure of micron strips. According to the proposed detection mechanism, namely electron heating, they expect an intrinsic response time of approximately 20 ps at the same temperature.
|
|
|
Bespalov AV, Gol'tsman GN, Semenov AD, Renk KF. Determination of the far-infrared emission characteristic of a cyclotron p-germanium laser by use of a superconducting Nb detector. Solid State Communications. 1991;80(7):503–6.
Abstract: We studied the far-infrared emission characteristics of a cyclotron p-germanium laser using a broad-band superconducting Nb film detector. For magnetic fields between ∼25 kOe and ∼50 kOe, emission in a frequency range from ∼50 cm-1 to ∼100 cm-1 with maximum intensity around 90 cm-1 was obtained. We determined, for fixed magnetic fields, electric field dependences of the emission intensity taking into account that the total electric field is a sum of the applied and the Hall electric field. An analysis of the emission intensity characteristic gives evidence that transitions between the two lowest Landau levels of light holes are responsible for the laser action.
|
|
|
Lang PT, Leipold I, Knott WJ, Semenov AD, Gol'tsman GN, Renk KF. New far-infrared laser lines from CH3Cl and CH3Br optically pumped with a continuously tunable high pressure CO2 laser. Appl Phys B. 1991;53(4):207–12.
Abstract: In this paper we report on the detection of new far-infrared laser lines from CH3Cl and CH3Br optically pumped with a continuously tunable high pressure CO2 laser. We found 80 new lines for CH3Cl and 9 new lines for CH3Br in the frequency region between 16 cm−1 and 41 cm−1, all due to stimulated Raman scattering. For the Raman gain regions bandwidths up to about 700 MHz were found. We also observed high intensity short far-infrared laser pulses of durations in the nanosecond regime.
|
|
|
Nebosis RS, Steinke R, Lang PT, Schatz W, Heusinger MA, Renk KF, et al. Picosecond YBa2Cu3O7−δdetector for far‐infrared radiation. J Appl Phys. 1992;72(11):5496–9.
Abstract: We report on a picosecond YBa2Cu3O7−δ detector for far‐infrared radiation. The detector, consisting of a current carrying structure cooled to liquid‐nitrogen temperature, was studied by use of ultrashort laser pulses from an optically pumped far‐infrared laser in the frequency range from 25 to 215 cm−1. We found that the sensitivity (1 mV/W) was almost constant in this frequency range. We estimated a noise equivalent power of less than 5×10−7 W Hz−1/2. Taking into account the results of a mixing experiment (in the frequency range from 4 to 30 cm−1) we suggest that the response time of the detector was few picoseconds.
|
|
|
Lang PT, Knott WJ, Leipold I, Renk KF, Semenov AD, Gol'tsman GN. Generation and detection of tunable ultrashort infrared and far-infrared radiation pulses of high intensity. Int J of Infrared and Millimeter Waves. 1992;13(3):373–80.
Abstract: We report on generation and detection of intense pulsed radiation with frequency tunability in the infrared and far-infrared spectral regions. Infrared radiation is generated with a transversally electrically excited high pressure CO2 laser. A laser pulse of a total duration of about 300 ns consisted, due to self mode locking, of a series of single pulses, some with pulse durations of less than 450 ps and peak powers larger than 20 MW. Using these pulses for optical with durations less than 400 ps were obtained. For detection a new ultrafast superconducting detector was used.
|
|