Smirnov KV, Vakhtomin YB, Divochiy AV, Ozhegov RV, Pentin IV, Slivinskaya EV, et al. Single-photon detectors for the visible and infrared parts of the spectrum based on NbN nanostructures [abstract]. In: Proc. Progress In Electromagnetics Research Symp. Moscow, Russia; 2009. p. 863–4.
Abstract: The research by the group of Moscow State Pedagogical University into the hot-electron phenomena in thin superconducting films has led to the development of new types ofdetectors [1, 2] and their use both in fundamental and applied studies [3–6]. In this paper, wepresent the results of the development and fabrication of receiving systems for the visible andinfrared parts of the spectrum optimised for use in telecommunication systems and quantumcryptography.
|
Fiore A, Marsili F, Bitauld D, Gaggero A, Leoni R, Mattioli F, et al. Counting photons using a nanonetwork of superconducting wires. In: Cheng M, editor. Nano-Net. Berlin, Heidelberg: Springer Berlin Heidelberg; 2009. p. 120–2.
Abstract: We show how the parallel connection of photo-sensitive superconducting nanowires can be used to count the number of photons in an optical pulse, down to the single-photon level. Using this principle we demonstrate photon-number resolving detectors with unprecedented sensitivity and speed at telecommunication wavelengths.
|
Ozhegov RV, Gorshkov KN, Smirnov KV, Gol’tsman GN, Filippenko LV, Koshelets VP. Terahertz imaging system based on superconducting integrated receiver. In: Proc. 2-nd Int. Conf. Terahertz and Microwave radiation: Generation, Detection and Applications.; 2010. p. 20–2.
Abstract: The development of terahertz imaging instruments for security systems is on the cutting edge of terahertz technology. We are developing a THz imaging system based on a superconducting integrated receiver (SIR). An SIR is a new type of heterodyne receiver based on an SIS mixer integrated with a flux-flow oscillator (FFO) and a harmonic mixer which is used for phase-locking the FFO. Developing an array of SIRs would allow obtaining amplitude and phase characteristics of incident radiation in the plane of the receiver. Employing an SIR in an imaging system means building an entirely new instrument with many advantages compare to traditional systems: i) high temperature resolution, comparable to the best results for incoherent receivers; ii) high spectral resolution allowing spectral analysis of various substances; iii) the local oscillator frequency can be varied to obtain images at different frequencies, effectively providing “color” images; iv) since a heterodyne receiver preserves the phase of the radiation, it is possible to construct 3D images. The paper presents a prototype THz imaging system using an 1 pixel SIR. We have studied the dependence of the noise equivalent temperature difference (NETD) on the integration time and also possible ways of achieving best possible sensitivity. An NETD of 13 mK was obtained with an integration time of 1 sec a detection bandwidth of 4 GHz at a local oscillator frequency of 520 GHz. An important advantage of an FFO is its wide operation range: 300-700 GHz.
|
Tret’yakov IV, Ryabchun SA, Kaurova NS, Larionov PA, Lobastova AA, Voronov BM, et al. Optimum absorbed heterodyne power for superconducting NbN hot-electron bolometer mixer. Tech Phys Lett. 2010;36(12):1103–5.
Abstract: Absorbed heterodyne power has been measured in a low-noise broadband hot-electron bolometer (HEB) mixer for the terahertz range, operating on the effect of electron heating in the resistive state of an ultrathin superconducting NbN film. It is established that the optimum absorbed heterodyne power for the HEB mixer operating at 2.5 THz is about 100 nW.
|
Ozhegov RV, Gorshkov KN, Okunev OV, Gol’tsman GN. Superconducting hot-electron bolometer mixer as element of thermal imager matrix. Tech Phys Lett. 2010;36(11):1006–8.
Abstract: The possibility of using a matrix of sensitive elements on a 12-mm-diameter hyperhemispherical lens in a thermal imager operating in the terahertz range has been studied. Dimensions of a lens region acceptable for arrangement of the matrix, in which the receiver noise temperature varies within 16% of the mean value, are determined to be 3.3% of the lens diameter. Deviations of the main lobe of the directivity pattern are evaluated, which amount to ±1.25° relative to the direction toward the optimum position of a mixer. The fluctuation sensitivity of the receiver measured in experiment is 0.5 K at a frequency of 300 GHz.
|