Gershenzon EM, Gol’tsman GN, Gousev YP, Elant’ev AI, Semenov AD. Electromagnetic radiation mixer based on electron heating in resistive state of superconductive Nb and YBaCuO films. IEEE Trans Magn. 1991;27(2):1317–20.
Abstract: A theory of an electron-heating mixer which makes it possible to calculate all the characteristics of the device is developed. It is shown that positive conversion gain is possible for such a mixer in the millimeter to near-infrared wavelength range. The dynamic range and the optimum heterodyne power can be selected from a very wide interval by varying the mixing element volume. Measurements made for Nb within the frequency range of 120-750 GHz confirm the theory. The conversion loss obtained at T=1.6 K and normalized to the element reaches 0.3 dB in the intermediate frequency band of 40 MHz; the possible noise temperature is 50 K. The estimation of noise temperature and output band for YBaCuO at T=77 yields 200 K and more than 10 GHz, respectively.
|
Kollberg EL, Gershenzon E, Goltsman G, Yngvesson KS. Hot electron mixers, the potential competition. In: Proc. ESA Symp. on Photon Detectors for Space Instrumentation.; 1992. p. 201–6.
Abstract: There is an urgent need in radio astronomy for low noise heterodyne receivers for frequencies above about 500 GHz. It is not certain that mixers based on superconducting quasiparticle tunnelling (SIS mixers) may turn out to be the answer to this need. In order to try to find an alternative way for realizing low noise heterodyne receivers for submillimeter waves, so called hot electron bolometric effects for mixing are now being investigated. Two basically different approaches are tried, one based on semiconductors and one on superconductors. Both methods are briefly discussed in this overview paper.
|
Voronov BM, Gershenzon EM, Gol'tsman GN, Gogidze IG, Gusev YP, Zorin MA, et al. Picosecond range detector base on superconducting niobium nitride film sensitive to radiation in spectral range from millimeter waves up to visible light. Sverkhprovodimost': Fizika, Khimiya, Tekhnika. 1992;5(5):955–60.
Abstract: Fast-operating picosecond detector of electromagnetical radiation is developed on the basis of fine superconducting film of niobium nitride with high sensitivity within spectral range from millimetric waves up to visible light. Detector sensitive element represents structure covering narrow parallel strips with micron sizes included in the rupture of microstrip line. Detecting ability of the detector and time constant measured using amplitude-simulated radiation of reverse wave tubes and pulse radiation of picosecond gas and solid-body lasers, constitute D*≅1010 W-1·cm·Hz-1/2 and τ≤5 ps respectively, at 10 K temperature. The expected value of time constant of the detector at 10 K obtained via extrapolation of directly measured dependence that is, τ ∝ τ-1, constitutes 20 ps. Experimental data demonstrate that detection mechanism is linked with electron heating effect.
|
Gershenzon EM, Gol'tsman GN, Karasik BS, Lugovaya GY, Serebryakova NA, Chinkova EV. Infrared radiation detectors on the base of electron heating in resistive state films from traditional superconducing materials. Sverkhprovodimost': Fizika, Khimiya, Tekhnika. 1992;5(6):1129–40.
Abstract: Characteristics of infrared radiation detectors based on electron heating in thin superconducting films transformed at T ≤ Tc to a resistive state by transport current and, if necessary, by magnetic field are investigated. A comparison is made of the characteristics of the detectors fabricated of different materials: aluminium, niobium, Mo0.5Re0.5. Some devices with different topology of the reception area are considered. Electron heating detectors are comparable by their sensitivity with superconducting bolometers, but differ in a high fast-response.
|
Prober DE. Superconducting terahertz mixer using a transition-edge microbolometer. Appl Phys Lett. 1993;62(17):2119–21.
|