Details
   web
Records
Author Yates, S. J. C.; Baryshev, A. M.; Baselmans, J. J. A.; Klein, B.; Güsten, R.
Title Fast Fourier transform spectrometer readout for large arrays of microwave kinetic inductance detectors Type Journal Article
Year 2009 Publication Applied Physics Letters Abbreviated Journal Appl. Phys. Lett.
Volume 95 Issue 4 Pages (down) 3
Keywords
Abstract Microwave kinetic inductance detectors have great potential for large, very sensitive detector arrays for use in, for example, submillimeter imaging. Being intrinsically readout in the frequency domain, they are particularly suited for frequency domain multiplexing allowing ~1000 s of devices to be readout with one pair of coaxial cables. However, this moves the complexity of the detector from the cryogenics to the warm electronics. We present here the concept and experimental demonstration of the use of fast Fourier transform spectrometer readout, showing no deterioration of the noise performance compared to the low noise analog mixing while allowing high multiplexing ratios.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number RPLAB @ gujma @ Serial 697
Permanent link to this record
 

 
Author Inderbitzin, K.; Engel, A.; Schilling, A.; Il'in, K.; Siegel, M.
Title An ultra-fast superconducting Nb nanowire single-photon detector for soft x-rays Type Journal Article
Year 2012 Publication Abbreviated Journal Appl. Phys. Lett.
Volume 101 Issue Pages (down)
Keywords SSPD, SNSPD, x-ray, Nb
Abstract Although superconducting nanowire single-photon detectors (SNSPDs) are well studied regarding the

detection of infrared/optical photons and keV-molecules, no studies on continuous x-ray photon

counting by thick-film detectors have been reported so far. We fabricated a 100 nm thick niobium

x-ray SNSPD (an X-SNSPD) and studied its detection capability of photons with keV-energies in

continuous mode. The detector is capable to detect photons even at reduced bias currents of 0.4%,

which is in sharp contrast to optical thin-film SNSPDs. No dark counts were recorded in extended

measurement periods. Strikingly, the signal amplitude distribution depends significantly on the photon

energy spectrum.VC
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number RPLAB @ seleznev @ Serial 878
Permanent link to this record