toggle visibility Search & Display Options

Select All    Deselect All
 |   | 
Details
   print
  Records Links
Author Nebosis, R. S.; Heusinger, M. A.; Semenov, A. D.; Lang, P. T.; Schatz, W.; Steinke, R.; Renk, K. F.; Gol'tsman, G. N.; Karasik, B. S.; Gershenzon, E. M. url  doi
openurl 
  Title Ultrafast photoresponse of an YBa2Cu3O7-δ film to far-infrared radiation pulses Type Journal Article
  Year 1993 Publication Opt. Lett. Abbreviated Journal Opt. Lett.  
  Volume 18 Issue (up) 2 Pages 96-97  
  Keywords YBCO HTS detectors  
  Abstract We report the observation of an ultrafast photoresponse of a high-T(c), film to far-infrared radiation pulses. The response of a sample, consisting of a current-carrying structured YBa(2)Cu(3)O(7-delta) film cooled to liquid-nitrogen temperature, was studied by use of ultrashort laser pulses from an optically pumped far-infrared laser in the frequency range from 0.7 to 7 THz. We found that the response time was limited by the time resolution, 120 ps, of our electronic registration equipment.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0146-9592 ISBN Medium  
  Area Expedition Conference  
  Notes PMID:19802049 Approved no  
  Call Number Serial 1660  
Permanent link to this record
 

 
Author Zhang, Zijing; Zhang, Jianlong; Wu, Long; Zhang, Yong; Zhao, Yuan; Su, Jianzhong doi  openurl
  Title Photon-counting chirped amplitude modulation lidar using a smart premixing method Type Journal Article
  Year 2013 Publication Opt. Lett. Abbreviated Journal Opt. Lett.  
  Volume 38 Issue (up) 21 Pages 4389-4392  
  Keywords photon-counting detector, lidar, Geiger mode APD, Geiger mode lidar  
  Abstract We proposed a new premixing method for photon-counting chirped amplitude modulation lidar (PCCAML). Earlier studies used the counting results of the returned signal detected by a Geiger mode avalanche photodiode detector (Gm-APD) to mix with the reference signal, called the postmixing method. We use an alternative method known as the premixing method, in which the reference signal is used to directly modulate the sampling gate width of the Gm-APD, and the mixing of the returned signal and the reference signal is completed before the Gm-APD. This premixing method is more flexible and may perform better than the postmixing method in terms of signal-to-noise ratio by cutting down a separated mixer commonly used in the postmixing lidar system. Furthermore, this premixing method lowers the demand for the sampling frequency of the Gm-APD. It allows the use of a much wider modulation bandwidth to improve the range accuracy and resolution. To the best of our knowledge, this is the first report to use the premixing method in the PCCAML system, which will benefit future lidar applications.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number Serial 1006  
Permanent link to this record
 

 
Author Hu, Xiaolong; Zhong, Tian; White, James E.; Dauler, Eric A. Najafi, Faraz; Herder, Charles H.; Wong, Franco N. C.; Berggren, Karl K. openurl 
  Title Fiber-coupled nanowire photon counter at 1550 nm with 24% system detection efficiency Type Journal Article
  Year 2009 Publication Optics Letters Abbreviated Journal Opt. Lett.  
  Volume 34 Issue (up) 23 Pages 3607-3609  
  Keywords SNSPD  
  Abstract We developed a fiber-coupled superconducting nanowire single-photon detector system in a close-cycled cryocooler and achieved 24% and 22% system detection efficiencies at wavelengths of 1550 and 1315 nm, respectively. The maximum dark count rate was ~1000 counts/s.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number RPLAB @ gujma @ Serial 679  
Permanent link to this record
 

 
Author Divochiy, A.; Misiaszek, M.; Vakhtomin, Y.; Morozov, P.; Smirnov, K.; Zolotov, P.; Kolenderski, P. url  doi
openurl 
  Title Single photon detection system for visible and infrared spectrum range Type Journal Article
  Year 2018 Publication Opt. Lett. Abbreviated Journal Opt. Lett.  
  Volume 43 Issue (up) 24 Pages 6085-6088  
  Keywords  
  Abstract We demonstrate niobium nitride based superconducting single-photon detectors sensitive in the spectral range 452-2300 nm. The system performance was tested in a real-life experiment with correlated photons generated by means of spontaneous parametric downconversion, where one photon was in the visible range and the other was in the infrared range. We measured a signal to noise ratio as high as 4x10(4) in our detection setting. A photon detection efficiency as high as 64% at 1550 nm and 15% at 2300 nm was observed.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0146-9592 ISBN Medium  
  Area Expedition Conference  
  Notes https://arxiv.org/abs/1807.04273 Approved no  
  Call Number Serial 1227  
Permanent link to this record
 

 
Author Churikov, Victor M.; Kopp, Victor I.; Genack, Azriel Z. openurl 
  Title Chiral diffraction gratings in twisted microstructured fibers Type Journal Article
  Year 2010 Publication Optics Letters Abbreviated Journal Opt. Lett.  
  Volume 35 Issue (up) 3 Pages 342-344  
  Keywords chiral diffracion gratings, optical fiber gratings, from chiralphotonics  
  Abstract We observed dips in transmission spectra of uniformly twisted pure-silica microstructured fibers. The spectral positions of the dips and their insensitivity to the surrounding medium are consistent with Bragg diffraction from the helical structure. The reproducibility of the variation of the dip wavelength with temperature up to 1000°C makes the chiral diffraction grating suitable for high-temperature sensing.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number Serial 853  
Permanent link to this record
Select All    Deselect All
 |   | 
Details
   print

Save Citations:
Export Records: